IMPORTANT: To aid reporting in case of loss or theft, please record the product's model and serial numbers in the space provided. The numbers are located in the rear of the product. Model No.: Serial No.: U.S.A. ONLY FOR CUSTOMERS IN U.K. IMPORTANT The wires in this mains lead are coloured in - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 3
is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 4
collection system for these products. EU ONLY A. Information on Disposal for Users (private households) 1. In the European Union Attention: If you want PLEASE CONTACT YOUR LOCAL SHARP DEALER OR AUTHORIZED SERVICE REPRESENTATIVE FOR ASSISTANCE IN DISPOSING OF THIS BATTERY. U.S.A. AND CANADA ONLY E4 - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 5
SHARP LCD product. To ensure safety and many years of trouble service life of your LCD product, please read the following precautions carefully before using the product. 1. Read instructions - All operating instructions must be read and understood before the product is operated. 2. Keep this manual - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 6
avoid these problems, make sure instructions in the compartment. • Do not mix old and new batteries. • Do not mix batteries of different types. Voltage specifications user support the monitor. • Ensuring the monitor is not overhanging the edge of the supporting furniture. • Not placing the monitor - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 7
where specifically noted. LED Backlight ● The LED backlight in this product has a limited lifetime. * If the screen gets dark or does not turn on, it may be necessary to replace the LED backlight. This LED backlight is exclusive to this product and must be replaced by an authorized Sharp servicing - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 8
specifications is required. • Since the monitor is heavy, consult your dealer before installing, removing or moving the monitor. • Mounting the monitor to cover the remote control sensor or buttons. 2 [5] * This monitor can be installed close to a wall. However, as the monitor emits heat during - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 9
a LAN 42 Controlling with a PC 44 Troubleshooting 50 Specifications 52 Mounting Precautions (For SHARP dealers and service engineers 56 Supplied Components If any component should be missing, please contact your dealer. Liquid Crystal Display Monitor: 1 Remote control unit: 1 Cable clamp - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 10
LCD panel 2. Remote control sensor (See page 15.) 3. Input switch (See page 18.) 4. Power switch (See page 16.) 5. Power LED (See page 16.) TIPS • Use a pointed object such as a pen tip to press the switches at the front of the monitor. 2 3 4 5 nRear view When the PN External speaker terminals - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 11
nRemote control unit 1 2 7 3 8 4 5 9 6 Part Names 1. Signal transmitter 2. POWER button (See page 16.) 3. MUTE button (See page 18.) 4. VOL +/- buttons (See page 18.) BRIGHT +/- buttons (See page 18.) Cursor control ( / / / ) buttons 5. DISPLAY button (See page 18.) 6. MODE button ( - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 12
manual of the equipment to be connected. • Be careful not to confuse the input terminal with the output terminal when connecting cables. Accidentally reversing cables connected to the input and output terminals may cause malfunctions and the other problems specifications of this monitor. the PN-ZB01 - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 13
Ω or greater and a rated input of at least 7 W. 1 2 3 Approx. 3-15/16 inch (10 cm) 1. Attach a speaker cable core (included with the PN-ZB01) to the end of the speaker cable connected to the monitor. 2. While pushing the tab, insert the tip of the cable. 3. Release the tab. TIPS • Be sure to - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 14
Cable clamp Removing the Handles The handles can be removed. Handle Handle screws Caution • The removable handles and handle screws are for use with this monitor. Do not use them for any other devices. • To attach handles, be sure to use the handles and handle screws which were removed from the - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 15
is approx. 16.4 feet (5 m) at an angle of approx 10° from the center to the top/ bottom/right/left of the remote control sensor. 2. See the instructions in the compartment and put in the supplied batteries (R-6 ("AA" size) x 2) with their plus (+) and minus (-) sides oriented correctly. 3. Close - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 16
in a malfunction. TIPS • When the main power switch is off, the monitor cannot be turned on. • If the monitor is in the input signal standby mode and you press the POWER button on the remote control unit, the monitor enters standby mode. • Setting the SCHEDULE flashes the power LED alternately in - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 17
, the internal battery may be exhausted. Please contact your local Sharp servicing dealer or service center for assistance with battery replacement. • Estimated service life of the internal battery: About 5 years (depending on monitor operation) • The initial battery was inserted at the factory when - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 18
The menu is displayed. Press or to select the screen size. (See page 19.) 7. DISPLAY Displays monitor information. When you press this button again, the display disappears. When the PN-ZB01 (optional) is attached, the display changes from INFORMATION1 → INFORMATION2 → clear display, and so on every - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 19
screen size with a different aspect ratio than the original image (e.g. TV broadcast or video input from external equipment). • When an ordinary non select the optimal screen size using the screen-size switching function of this monitor. With some software, there may be noise or distortion at the - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 20
BLACK LEVEL 30 TINT 30 COLORS 30 SHARPNESS 12 RGB INPUT RANGE 2 PC D-SUB FULL MOVE OSD···[DISPLAY] 1920x1080 V: 60 Hz H: 67.5 kHz OK···[MENU] PN-ZB01 (optional) is attached. Menu Item SETUP HOT PLUG CONTROL DVI RS-232C/LAN SELECT LAN SETUP AUTO ASSIGN FIXED IP ADDR. SPEAKER - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 21
COLORS Adjusts the color intensity. SHARPNESS Adjusts the sharpness of the image. RGB INPUT input) You can adjust more specifically. (See page 28.) COLOR MODE can also be changed using a remote control unit. (See page 18.) color temperature using PRESET. USER Used for adjusting R-/G-/B-CONTRAST - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 22
than white, color tone may differ from the PRESET.) GAMMA Selects the gamma. USER sets the gamma to the sent value (see page 33). (In PIP mode, ON DELAY You can delay the screen display after the monitor is turned on. The period can be set up to 60 seconds in units of one second. When this function - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 23
Determines whether or not to set the monitor to go into standby mode when there is no operation from the remote control unit, RS-232C commands, or LAN with a network device other than a monitor, individually change the IP address. SPEAKER SELECT Selects the speaker to be used. HDMI AUTO VIEW When - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 24
input terminal. (AUTO / PAL / PAL-60 / SECAM / NTSC3.58 / NTSC4.43 in speaker or the external speaker select OFF. (Perform manual adjustment of the screen , AV COMPONENT and AV VIDEO When the PN-ZB01 (optional) is attached: PC DVI-D, smoothly when a group of monitors are aligned in multiples to - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 25
no signals for the sub screen are input in PIP, PbyP, or PbyP2 mode. MANUAL....... Displays a main screen and a black sub screen. AUTO Displays the main screen as sRGB, the following items cannot be set. WHITE BALANCE, PRESET, USER, COPY TO USER, and GAMMA • When the COLOR MODE is set to VIVID or - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 26
aligned in the vertical direction in ENLARGE V. 5. Set the section of the separated image to be displayed on each monitor in ENLARGE-POS. 1) Press . 2) Press , , or to select position, then press MENU . TIPS • When Enlarge is used, the SCREEN MOTION function is disabled. • When Enlarge - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 27
- - - - - - - - - - - - - - - - - - - 1920x1080 V: 60 Hz H: 67.5 kHz OK···[MENU] 1. Press or to select the SCHEDULE number, and ON : Switches the monitor on at the specified time. OFF : Switches the monitor off at the specified time and puts the monitor in standby mode. - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 28
(AV VIDEO) Specify whether to perform 3-dimension Y/C separation. If dot interference or cross-color The adjustment pattern will appear. Adjust the screen automatically or manually. 4. When adjustment is finished, press the [Esc] specifications of the input signal and is not a malfunction.) E 28 - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 29
off and then back on. When the PN-ZB01 (optional) is attached, press , SERVICE & SUPPORT, and SNMP (See page 23, and pages 46 to 49.) ADJUSTMENT LOCK You can disable operations on the monitor and the remote When using an optional part, if instruction appears, change the setting accordingly. - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 30
page 31), you can make input mode selection/adjustment or can check the status of a specific monitor. Precautions when the PN-ZB01 (optional) is attached • To control the monitor via RS-232C, set RS-232C/LAN SELECT to RS-232C. • You cannot use RS-232C and LAN control simultaneously. PC connection - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 31
the "One-to-one connection with a PC" section. nID numbers You can assign a unique ID number to each monitor (see page 23). This allows you to control a particular monitor in a daisy chain of monitors. You can assign ID numbers either from the menu screen or from the PC using RS-232 cable. [Example - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 32
ID number: 2 to 20.* WAIT OK 002 IDLK0000 ← Canceling fixed ID number setting WAIT ← Canceling IDLK OK 002 ← Cancelation complete VOLM0010 The volume of the monitor with ID number: OK 001 ← 1 (the one directly connected to the PC) is set to 10. (IDLK is canceled.) * The IDLK command remains - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 33
specific set, assign ID numbers to each monitor in advance. When some monitors do not return their responses, the probable cause is that the monitors (0 to F). nSaving the GAMMA user data Use the user data save command (UGSV) to save the transferred user data in the monitor. If the data is not saved - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 34
Controlling the Monitor with a PC (RS-232C) RS-232C command table How to read the command in power standby mode regardless of the STANDBY MODE setting. PN-ZB01 (optional) limitations (A) When PN-ZB01 (optional) is not attached, (B) When PN-ZB01 (optional) is attached. ○ : The command can be - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 35
Controlling the Monitor with a PC (RS-232C) SCREEN menu Auto CLOCK Function Command Direction ASNC W CLCK WR PHASE positioning size RESOLUTION RESET PHSE WR Position of HPOS WR - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 36
the Monitor with a PC (RS-232C) PICTURE menu Function Auto ANALOG GAIN ANALOG OFFSET CONTRAST BLACK LEVEL TINT COLORS SHARPNESS RGB 127 0-60 0-60 0-60 0-60 0-24 0-2 0-2 1-2 1-2 1-2 1-2 0-2 0-2 0-1 0-1 -10-10 1 -10-10 2 -10-10 3 0 2 3 4 0 1-18 COPY TO USER GAMMA USER R-CONTRAST - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 37
10-990 5-20 0-1 0-1 14 1 2 3 4 5 6 0 1-60 0-1 0-1 0-1 0-1 0-1 0-255 : xxx : yyy 0-2 0-1 0-1 0 PN-ZB01 is attached, the IP address and MAC address are both displayed.) 0: 9600bps, 1: 19200bps, 2: 38400bps 0: Internal speaker, 1: External speaker 0: OFF, 1: ON Copy to all monitors. Copy to the monitor - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 38
Controlling the Monitor with a PC (RS-232C) OPTION menu Function Date mode is AV) ○ 0-1 0-1 0: OFF, 1: ON ○ 0-1 0-1 0: OFF, 1: ON ○ 0-5 0-5 0: AUTO, 1: PAL, 2: PAL-60, 3: SECAM, 4: NTSC3.58, 5: NTSC4.43 ○ 0-2 0-2 0: VARIABLE1, 1: FIXED, 2: VARIABLE2 ○ 0-1 0-1 0: 1.0Vrms, 1: 0.5Vrms - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 39
-999 -999-999 0: OFF, 1: ON 0: OFF, 1: 2 x 2, 2: 3 x 3, 3: 4 x 4, 4: 5 x 5 1 x 1 (OFF) to 5 x 5 ("m x n" is expressed as "mn", where m and n are the numbers of monitors specified for the longest direction and the shortest direction respectively.) Specifies values in the order of IMAGE POSITION IN - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 40
, 2: SUB 0-1 0: POS1, 1: POS2 0-2 0: POS1, 1: POS2, 2: POS3 0-1 0: MANUAL, 1: AUTO *2 *1 (A) (B) ○ ○ ○ -○ ○○ ○○ ○○ ○-○ -○ -○ ○○ ○○ 0: ALL RESET 1, 1: ALL RESET 2 0-2 0: OFF, 1:ON1, 2:ON2 0-2 0: REMOTE CONTROL, 1: MONITOR BUTTONS, 2: BOTH 0-2 0: ON1, 1: OFF, 2: ON2 0-1 0: ON, 1: OFF - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 41
··· xxxx (xxxx: 32 pieces) xxxx: 0000-1023 0 0 Control/Response contents aa: Block number xxxx: 32 pieces of user data cc: Checksum (ASCII data) of the block number and user data xxxx: User data of 32 pieces Initialize the user data. Save the user data in the monitor. *2 *1 (A) (B) ○○○ 41 E - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 42
PN-ZB01 (optional) is attached, your monitor can be connected to a LAN allowing you to control it from a PC on the LAN. You can also configure the monitor to send e-mail notification when it has a problem change this setting to ON. To set the address manually, set this to OFF. IP ADDRESS If the DHCP - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 43
• This monitor is factory monitor. 2. Set RS-232C/LAN SELECT on the SETUP menu to LAN. 3. Set DHCP CLIENT to OFF in LAN SETUP on the SETUP menu. PC operation 4. Launch Internet Explorer, in the "Address" box type "http://192.168.150.2/" and press the Enter key. You will be prompted to enter a user - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 44
the LAN. Caution • Wait 10 seconds after clicking [OK] before proceeding. • When operating using the remote control unit or similar, click [Refresh]. TIPS • When the IP address is set manually, the IP addresses of the monitor connected to the RS-232C output terminal and the daisy chain of connected - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 45
■ ADJUSTMENT You can adjust these settings which are also available on the monitor's menu. • SCREEN (See page 21.) • PICTURE (See page 21 control the operations corresponding to the buttons (POWER INPUT SIZE ) on the remote control unit. (See page 18.) TIPS • After changing DISPLAY COLOR PATTERN - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 46
to "ON". To set the address manually, set this to "OFF". IP monitor. After entering a user name and password, click [Apply]. ACCEPT IP ADDRESS You can limit access to this monitor by registering IP addresses of PCs that should have access. To limit access, specify the option "From only specific - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 47
a domain name, make sure to specify the DNS server as well. (See page 46.) ORIGINATOR E-MAIL ADDRESS Specify the e-mail address for this monitor. This address becomes the e-mail address of the originator. ORIGINATOR NAME Specify the name for the originator. This name appears in the "Originator Name - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 48
a PC (LAN) ■ MAIL (RECIPIENT) This screen allows you to specify the recipients of the e-mail sent periodically or when the monitor has an error. ■ MAIL (PERIODICAL) When PERIODICAL for CONDITION of MAIL (RECIPIENT) is checked, set the date and time to send the mail. RECIPIENT E-MAIL - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 49
letters and symbols can be used for the community name, user name and password. ■ SERVICE & SUPPORT (URL INFORMATION) You can display a specific URL in the URL INFORMATION field on the INFORMATION screen when an error occurs in the monitor. (See page 45.) SNMP SETTING Set whether to enable or - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 50
If you are experiencing any problem with your display, before calling for service, please review the following troubleshooting tips. There is no picture or sound. • Is the power cord disconnected? (See page 14.) • Is the main power switch off? (See page 16.) • Is the monitor in standby mode (the - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 51
rise in temperature is likely. Internal temperature rises quickly if the vents on the monitor are blocked. - Internal temperature rises quickly if dust accumulates inside the monitor or around the vents. Remove dust if possible. Ask SHARP dealer about removing internal dust. Troubleshooting 51 E - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 52
Specifications nProduct Specifications Model PN-E602 LCD component 60" Class [60-1/16 inch (152.5cm) diagonal] TFT LCD Max. resolution (pixels) 1920 x 1080 Max. colors Approx. 1.06 billion colors Pixel pitch 0.692 mm (H) × 0.692 mm (V) Viewing angle 176° right/left/up/down (contrast - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 53
15/16 [50] Specifications VESA holes * 7-7/8 PN-ZB01 (optional) is not connected. *2 When AUTO INPUT CHANGE is set to OFF. DMPM: Digital Monitor Power Management DMPM Monitor ON Active OFF Screen Display No display Power consumption 165 W*1 1.0 W*1*2 nDDC (plug and play) The monitor supports - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 54
Specifications nCompatible signal timing (PC) 31.0kHz 48.4kHz 56.5kHz 60.0kHz 67.5kHz 47.8kHz 60.3kHz 49.7kHz 60.0kHz 64.0kHz 80.0kHz 47. image will be cut down to panel size then displayed. *2 Available when the PN-ZB01 (optional) is attached. * All are compliant only with non-interlaced. * - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 55
nPC/AV DVI-D input terminal pins (DVI-D 24 pin) Specifications nPC/AV HDMI input terminal pins (HDMITM Connector) No. Function 1 TMDS data 2- 2 TMDS data 2+ 3 TMDS data 2/4 shield 4 N.C. 5 N.C. 6 DDC clock 7 DDC data 8 N.C. 9 TMDS data 1- 10 TMDS - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 56
Mounting Precautions (For SHARP dealers and service engineers) • When installing, removing or moving the monitor, ensure that this is carried out by at least 2 people. • Be sure to use a wall-mount bracket designed or designated for mounting the monitor. • This monitor is designed to be installed on - Sharp PN-E602 | PN-E602 Professional LCD Monitor Operation Manual - Page 57