Sharp PN-L602B PN-L802B Professional LCD Monitor Operation Manual
Sharp PN-L602B Manual
View all Sharp PN-L602B manuals
Add to My Manuals
Save this manual to your list of manuals |
Sharp PN-L602B manual content summary:
- Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 1
PN-L802B LCD MONITOR OPERATION MANUAL - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 2
IMPORTANT: To aid reporting in case of loss or theft, please record the product's model and serial numbers in the space provided. The numbers are located in the rear of the product. Model No.: Serial No.: U.S.A. ONLY FOR CUSTOMERS IN U.K. IMPORTANT The wires in this mains lead are coloured in - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 3
is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 4
EU ONLY A. Information on Disposal for Users (private households) 1. In the European SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs SHARP DEALER OR AUTHORIZED SERVICE REPRESENTATIVE FOR ASSISTANCE IN DISPOSING OF THIS BATTERY. U.S.A. AND CANADA - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 5
rack, unless proper ventilation is provided or the manufacturer's instructions are followed. 9. Power cord protection - The power cords must be routed properly to prevent people from stepping on them or objects from resting on them. 10. The screen used in this product is made of glass. Therefore - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 6
RS-232C input/output terminals. If a monitor is not positioned in a sufficiently stable location, it can be potentially hazardous due to falling. Many injuries, particularly to children, can be avoided by taking simple precautions such as: • Using fixing devices like wall mount brackets recommended - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 7
the PC. - Do not operate the screen with a hard or pointed object such as a fingernail, pen, or pencil. - Two touch panels cannot be used when two displays are connected to the computer. Only the touch panel on the display that is set as the primary monitor will be operable. - If another USB - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 8
bracket compliant with VESA specifications is required. • Since the monitor is heavy, consult your dealer before installing, removing or moving the monitor. • Mounting the monitor on the wall requires special expertise and the work must be performed by an authorized SHARP dealer. You should - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 9
a PC 45 Troubleshooting 51 Specifications 53 Mounting Precautions (For SHARP dealers and service engineers 57 For information on the touch panel driver, see the Touch Panel Driver Operation Manual. For information on the Pen Software, see the Pen Software Operation Manual. Supplied Components - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 10
terminals are available by attaching the PN-ZB01 4 expansion board (optional). 6. PC/AV HDMI input terminal (See page 12.) 7. PC D-sub input terminal (See page 12.) 8. Audio input terminal (See page 12.) 9. Audio output terminals (See page 12.) 10. RS-232C output terminal (See page 12.) 11. RS - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 11
8 4 5 9 6 Part Names 1. Signal transmitter 2. POWER button (See page 16.) 3. MUTE button (See page 21.) 4. VOL +/- buttons (See page 21.) BRIGHT +/- buttons (See page 21.) Cursor control ( / / / ) buttons 5. DISPLAY button (See page 21.) 6. MODE button (See page 21.) 7. INPUT button (See - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 12
PC is changed. The screen is adjusted automatically when SELF ADJUST in the OPTION menu is set to ON. • If the audio output from the playback device is connected directly to speakers or other devices, the video on the monitor may appear delayed from the audio portion. Audio should be played through - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 13
other than PC DVI-D/AV DVI-D for the input mode. In this case, turn off the power to all the monitors connected in a daisy chain and then turn the power on again. • When connecting monitors in a daisy chain set AUTO INPUT CHANGE to OFF. • Video output is disabled in the following cases: When the - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 14
Cord Caution • Use only the power cord supplied with the monitor. 1. Turn off the main power switch. 2. Plug the power cord (supplied) into the AC input terminal. 3. Plug the power cord (supplied) into the AC power outlet. 3 For power outlet Main power switch 1 2 Power cord (Supplied) AC input - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 15
The operation range of the remote control unit is approx. 16.4 feet (5 m) at an angle of approx 10° from the center to the top/ bottom/right/left of the remote control sensor. 2. See the instructions in the compartment and put in the supplied batteries (R-6 ("AA" size) x 2) with their plus (+) and - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 16
signal standby mode and you press the POWER button on the remote control unit, the monitor enters standby mode. • Setting the SCHEDULE flashes the power LED alternately in red and orange in standby mode. • To disable the logo screen from displaying when turning the power ON, set LOGO SCREEN to OFF - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 17
/time setting screen appears when the power is turned on, the internal battery may be exhausted. Please contact your local Sharp servicing dealer or service center for assistance with battery replacement. • Estimated service life of the internal battery: About 5 years (depending on monitor operation - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 18
• Settings for touch panel operation such as the touch mode and actions of the function buttons can be changed in the touch panel driver. For details, see the manual for the touch panel driver. • In Windows 7, if the checkmark has been removed from "Enable multi-touch gestures and inking" in "Pen - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 19
movement, lift your finger/pen. *1 In Windows XP/Windows Vista, the settings can be changed in the touch panel driver. *2 The settings can be changed in "Pen and touch" of Control Panel in Windows 7. For details, see Windows Help. nFinger actions Zoom Use in a screen that is capable of enlargement - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 20
the angle. Eraser The eraser is used with the Pen Software. For the procedure for using the eraser, refer to the Pen Software Operation Manual. Caution • When using the eraser, gently bring the cloth side into contact with the screen. Touching the screen with one of the non-cloth sides will damage - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 21
of the monitor. Input mode Video PC D-SUB PC D-sub input terminal*1 PC HDMI PC/AV HDMI input terminal*2 AV HDMI PC/AV HDMI input terminal*2 AV COMPONENT PC D-sub input terminal*1 AV VIDEO PC D-sub input terminal*1 Audio Audio input terminal *3 Audio input terminal When the PN-ZB01 - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 22
respect the creator's intentions, set the screen size to "NORMAL". • When playing commercial software, parts of the image (like subtitles) may be cropped. In this case select the optimal screen size using the screen-size switching function of this monitor. With some software, there may be noise or - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 23
31 CONTRAST 30 BLACK LEVEL 30 TINT 30 COLORS 30 SHARPNESS 12 RGB INPUT RANGE PC D-SUB FULL MOVE OSD···[DISPLAY] 1920x1080 V: 60 Hz H: 67.5 kHz OK···[MENU] 4. Press or to adjust the setting. ▲ ▲ SCREEN PICTURE AUDIO SETUP OPTION PIP/PbyP PICTURE 1/2 AUTO ANALOG GAIN 64 ANALOG - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 24
) You can adjust more specifically. (See page 30.) COLOR MODE Changes the color mode on the screen. The color mode on the screen can also be changed using a remote control unit. (See page 21.) * sRGB is PC input only. See page 21 for details. (In PIP mode, the main side setting is reflected in the - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 25
AUDIO Outputs audio signals as monaural. LANGUAGE Sets the display language for the menu screen. POWER ON DELAY You can delay the screen display after the monitor is turned on. The period can be set up to 60 seconds in units of one second. When this function is activated, the power LED flashes - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 26
to the screen size control signal included in the video signal input from the AV HDMI input terminal. COPY SETTING VALUE When the monitor has been connected to multiple monitors by RS-232C, the settings in the monitor can be copied to the monitor connected to the RS-232C output terminal and - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 27
may not be detected properly and a priority may change, depending on the connected equipment or video signals.) TOUCH PANEL MODE (PC input) When the resolution is 1920 x 1080, setting this to ON improves touch panel tracking. When two screens are displayed, or when V-POS or V-SIZE is adjusted on the - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 28
simultaneously. Set this function with "PIP MODES" in the PIP/PbyP menu. PIP Main screen A sub screen is displayed inside a main screen. Sub screen PbyP Main screen Sub screen A main screen and a sub screen are displayed in a line. PbyP2 Main screen Sub screen Displays a main screen which - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 29
overlap. • If D-SUB of INPUT SELECT on the OPTION menu is set to AV VIDEO, the input mode will switch to AV VIDEO (D-SUB) regardless if set to D-SUB or VIDEO. (1) ●: SCHEDULE effective -: SCHEDULE not effective (2) POWER ON : Switches the monitor on at the specified time. OFF : Switches the - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 30
CD- ROM drive. 2. Open [CD Drive] in [Computer]. In Windows XP, open [CD Drive] in [My Computer]. 3. Double-click [Adj_uty.exe] in the [Monitor] folder. The adjustment pattern will appear. Adjust the screen automatically or manually. 4. When adjustment is finished, press the [Esc] on the computer - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 31
, the power LED flashes in red and the screen displays a message: STATUS [xxxx]. LED When a hardware error is detected, the power LED flashes in red. POWER BUTTON Normally, leave this setting as MONITOR. When using an optional part, if instruction appears, change the setting accordingly. CONTROLLER - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 32
by using a PC. By assigning ID numbers to each monitor (see page 33), you can make input mode selection/adjustment or can check the status of a specific monitor. Precautions when the PN-ZB01 (optional) is attached • To control the monitor via RS-232C, set RS-232C/LAN SELECT to RS-232C. • You cannot - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 33
a timeout for the command response, specify 10 seconds or longer. When connecting multiple monitors in a daisy chain, set the timeout to at least the product of the monitor's position from the computer multiplied by 10 seconds. Example) 3rd monitor from computer: 30 seconds or longer. • Provide an - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 34
one directly connected to the PC) is set to 10. (IDLK is canceled.) * The IDLK command remains effective until it is canceled, or power is shut off. IDCK Provides screen display of the ID number currently assigned to a monitor, and the ID number currently set for IDLK (if any). Example: (After - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 35
the data is not saved, it will be cleared when: • The main power switch is off • STANDBY MODE is LOW POWER and the monitor enters standby mode nActivating the GAMMA user data To activate the transferred user data, select USER for GAMMA of the PICTURE menu, or send the corresponding RS-232C command - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 36
power standby mode regardless of the STANDBY MODE setting. "○" indicates a command which cannot be used in power standby mode when STANDBY MODE is set to LOW POWER. "-" indicates a command which cannot be used in power standby mode regardless of the STANDBY MODE setting. PN VIDEO (BNC) / AV VIDEO - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 37
Controlling the Monitor with a PC (RS-232C) SCREEN menu Auto CLOCK Function Command Direction ASNC W contents 0-1200 0-63 0-100 When the input mode is PC D-SUB, PC RGB. When the input mode is PC D-SUB, PC RGB. Varies depending on the signal. When the input mode is PC D-SUB, PC RGB. 0-800 on - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 38
CMVY CMVG CMVC CMVB CMVM CRST W BMOD WR CTMP WR Parameter 1 0-127 0-127 0-60 0-60 0-60 0-60 0-24 0-2 0-2 1-2 1-2 1-2 1-2 0-2 0-2 0-1 0-1 -10-10 1 -10-10 2 -10-10 3 0 2 3 0 1-18 COPY TO USER GAMMA USER R-CONTRAST G-CONTRAST B-CONTRAST R-OFFSET G-OFFSET B-OFFSET CRTR WR CRTG WR CRTB WR OFSR - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 39
on the screen. 0: OFF, 1: ON, 2: ON (turns OFF after 4 sec.) (When the PN-ZB01 is attached, the IP address and MAC address are both displayed.) 0: 9600bps, 1: 19200bps, 2: 38400bps 0: Internal speaker, 1: External speaker 0: OFF, 1: ON Copy to all monitors. Copy to the monitor with the set ID Number - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 40
ZOOM2 SPECIAL SETTING (PC D-SUB, PC RGB) Z2SP WR SCAN MODE SCAN WR POWER MANAGEMENT (PC) PMNG WR POWER MANAGEMENT (AV) PMAV WR COLOR SYSTEM CSYS WR AUDIO OUTPUT(RCA) AOUT WR AUDIO LEVEL(STEREO MINI) AIVP WR SELF ADJUST AADJ WR AUTO INPUT CHANGE AINC WR TOUCH PANEL MODE GMDP WR - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 41
ERR" when LOW POWER is selected for STANDBY MODE. 0-2 0: OFF, 1: OSD & LED, 2: LED 0-2 0: OFF, 1: OSD & LED, 2: LED 0-1 0: MONITOR, 1: CONTROLLER 0-2 0: D-SUB, 1: HDMI ("ERR" when MONITOR is selected for POWER BUTTON.) 2: DVI-D ("ERR" when MONITOR is selected for POWER BUTTON.) *2 *1 (A) (B) 41 - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 42
main power switch 3 Standby mode by RS-232C or LAN 4 Input signal waiting mode by No Signal 6 Standby mode by abnormal temperature 8 Standby mode by SCHEDULE setting 20 Standby mode by OFF IF NO OPERATION setting *2 *1 (A) (B) ○ ○ ○ - ● ○ ● ○○ ○ ● Commands for setting of the GAMMA user data - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 43
the values of the LAN settings to the factory preset values. Select ON and then press MENU . TIPS • When the IP address is set manually, the IP addresses of the monitor connected to the RS-232C output terminal and the daisy chain of connected monitors that follows can be assigned automatically - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 44
the power ON to the monitor. 2. Set RS-232C/LAN SELECT on the SETUP menu to LAN. 3. Set DHCP CLIENT to OFF in LAN SETUP on the SETUP menu. PC operation 4. Launch Internet Explorer, in the "Address" box type "http://192.168.150.2/" and press the Enter key. You will be prompted to enter a user - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 45
the PC to the LAN. Caution • Wait 10 seconds after clicking [OK] before proceeding. • When operating using the remote control unit or similar, click [Refresh]. TIPS • When the IP address is set manually, the IP addresses of the monitor connected to the RS-232C output terminal and the daisy chain of - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 46
a PC (LAN) ■ INFORMATION Information about this monitor appears. ■ ADJUSTMENT You can adjust these settings which are also available on the monitor's menu. • SCREEN (See page 24.) • PICTURE (See page 24.) • PICTURE (ADVANCED) (See page 30.) • AUDIO (See page 25.) • SETUP (See page 25.) • OPTION - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 47
set to "From only specific IP addresses", enter the IP addresses that you want to allow. TIPS • The USER user name and/or password after it has been set, make the box empty and click [Apply]. TIPS • When the IP address is set manually, the IP addresses of the monitor connected to the RS-232C output - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 48
monitor has an error. The settings depend on the configuration of your LAN. Ask your LAN administrator for details. MONITOR NAME Specify a name for this monitor as it should appear on the Internet Explorer screen display for this monitor in the Internet Explorer window. TIPS • The MONITOR NAME can - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 49
a PC (LAN) ■ MAIL (RECIPIENT) This screen allows you to specify the recipients of the e-mail sent periodically or when the monitor has an error. ■ MAIL (PERIODICAL) When PERIODICAL for CONDITION of MAIL (RECIPIENT) is checked, set the date and time to send the mail. RECIPIENT E-MAIL ADDRESSES - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 50
can be used for the community name, user name and password. ■ SERVICE & SUPPORT (URL INFORMATION) You can display a specific URL in the URL INFORMATION field on the INFORMATION screen when an error occurs in the monitor. (See page 46.) SNMP SETTING Set whether to enable or disable SNMP. VERSION - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 51
any problem with your display, before calling for service, please review the following troubleshooting tips. There is no picture or sound. • Is the power cord disconnected? (See page 14.) • Is the main power switch off? (See page 16.) • Is the monitor in standby mode (the power LED illuminating - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 52
problems. When this occurs, "TEMPERATURE" is displayed on the screen and the Power LED flashes red and green alternately. (When TEMPERATURE ALERT is set to OSD & LED. This varies depending on the setting.) • If the internal temperature rises further, the monitor automatically enters standby mode - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 53
[When PN-ZB01 (optional) is attached] 10 BASE-T/100 BASE-TX Speaker output 7 W + 7 W Touch Panel Detection method Infrared camera method Detection area inch (mm) 69-3/4 x 39-1/4 (1771.2 x 996.3) PC connector USB (1.1 compliant) Power supply Supplied from USB Touch pen Ultrasonic - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 54
Yes No No DMPM: Digital Monitor Power Management DMPM Monitor ON Active OFF Screen Display No display Power consumption 255 W*1 1.0 W*1*2 *1 When PN-ZB01 (optional) is not connected. *2 When AUTO INPUT CHANGE is set to OFF. nDDC (plug and play) The monitor supports the VESA DDC (Display Data - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 55
Specifications nCompatible signal timing (PC) Screen resolution VESA 640 × 480 800 × 600 848 × 480 1024 × 768 1152 × 864 1280 × 768 1280 × 800 1280 × 960 1280 × 1024 Wide 1360 × 768 1400 × 1050 1440 × 900 1600 × 1200*1 1680 × 1050 1920 × 1200*1 1280 × 720 1920 × 1080 US when the PN-ZB01 ( - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 56
input 9 +5V 2 Green video signal input 10 GND 3 Blue video signal input 11 N.C. 4 N.C. 12 DDC data 5 GND 13 Hsync signal input 6 GND for red video signal 14 Vsync signal input 7 GND for green video signal 15 DDC clock 8 GND for blue video signal nPC/AV DVI-D output terminal pins (DVI - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 57
(For SHARP dealers and service engineers) • When installing, removing or moving the monitor, ensure that this is carried out by at least 6 people. • Be sure to use a wall-mount bracket designed or designated for mounting the monitor. • This monitor is designed to be installed on a concrete wall or - Sharp PN-L602B | PN-L802B Professional LCD Monitor Operation Manual - Page 58
PN-L802B Mu EN12A(1)
PN-L802B
LCD MONITOR