Sharp XG-P25X XG-P25X Operation Manual - Page 8

Caution Concerning the Lamp, Replacement, Cautions Concerning the Setup of, the Projector, Notes - lamp life

Page 8 highlights

Important Information IMPORTANT SAFEGUARDS LAMP REPLACEMENT CAUTION BEFORE REMOVING THE SCREW, DISCONNECT POWER CORD. HOT SURFACE INSIDE ALLOW 1 HOUR TO COOL BEFORE REPLACING THE LAMP. REPLACE WITH SAME SHARP LAMP UNIT TYPE BQC-XGP25X//1 ONLY. UV RADIATION : CAN CAUSE EYE DAMAGE. TURN OFF LAMP BEFORE SERVICING. MEDIUM PRESSURE LAMP : RISK OF EXPLOSION. POTENTIAL HAZARD OF GLASS PARTICLES IF LAMP HAS RUPTURED. HANDLE WITH CARE. SEE OPERATION MANUAL. Caution Concerning the Lamp Replacement See "Replacing the Lamp" on pages 62 and 63 . PRODUCT DISPOSAL This projector utilizes tin-lead solder, and a pressurized lamp containing a small amount of mercury. Disposal of these materials may be regulated due to environmental considerations. For disposal or recycling information, please contact your local authorities or, if you are located in the United States of America, the Electronics Industries Alliance: www.eiae.org . Caution Concerning the Lamp Unit Potential hazard of glass particles if lamp ruptures. In case of lamp rupture, contact your nearest Sharp Authorized LCD Projector Dealer or Service Center for a replacement. See "Replacing the Lamp" on pages 62 and 63 . CAUTION PRECAUCIÓN PRÉCAUTION BQC-XGP25X//1 Cautions Concerning the Setup of the Projector For minimal servicing and to maintain high image quality, SHARP recommends that this projector be installed in an area free from humidity, dust and cigarette smoke. When the projector is subjected to these environments, the lens must be cleaned more often. As long as the projector is properly maintained in this manner, use in these environments will not reduce the overall operation life. Please note that all internal cleaning must be performed by a Sharp Authorized LCD Projector Dealer or Service Center. Notes on Operation • The exhaust vent, the lamp cage cover and adjacent areas may be extremely hot during projector operation. To prevent injury, do not touch these areas until they have sufficiently cooled. • Allow at least 12 inches (30 cm) of space between the exhaust vent and the nearest wall or obstruction. • If the cooling fan becomes obstructed, a protection device will automatically turn off the projector lamp. This does not indicate a malfunction. Remove the projector power cord from the wall outlet and wait at least 10 minutes. Then turn on the power by plugging the power cord back in. This will return the projector to the normal operating condition. E-5 XG-P25X/CD (E)-a 5 02.3.19, 7:15 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

E-5
Important
Information
IMPORTANT SAFEGUARDS
Caution Concerning the Lamp
Replacement
See “Replacing the Lamp” on pages
62
and
63
.
Cautions Concerning the Setup of
the Projector
For minimal servicing and to maintain high image quality,
SHARP recommends that this projector be installed in
an area free from humidity, dust and cigarette smoke.
When the projector is subjected to these environments,
the lens must be cleaned more often. As long as the
projector is properly maintained in this manner, use in
these environments will not reduce the overall operation
life. Please note that all internal cleaning must be
performed by a Sharp Authorized LCD Projector Dealer
or Service Center.
Notes on Operation
The exhaust vent, the lamp cage cover and adjacent
areas may be extremely hot during projector
operation. To prevent injury, do not touch these areas
until they have sufficiently cooled.
• Allow at least 12 inches (30 cm) of space between
the exhaust vent and the nearest wall or obstruction.
• If the cooling fan becomes obstructed, a protection
device will automatically turn off the projector lamp.
This does not indicate a malfunction. Remove the
projector power cord from the wall outlet and wait at
least 10 minutes. Then turn on the power by plugging
the power cord back in. This will return the projector
to the normal operating condition.
PRODUCT DISPOSAL
This projector utilizes tin-lead solder, and a pressurized
lamp containing a small amount of mercury. Disposal of
these materials may be regulated due to environmental
considerations. For disposal or recycling information,
please contact your local authorities or, if you are located
in the United States of America, the Electronics Industries
Alliance: www.eiae.org .
Caution Concerning the Lamp Unit
Potential hazard of glass particles if lamp ruptures. In
case of lamp rupture, contact your nearest Sharp
Authorized LCD Projector Dealer or Service Center for
a replacement.
See “Replacing the Lamp” on pages
62
and
63
.
CAUTION
PRECAUCIÓN
PRÉCAUTION
BQC-XGP25X//1
LAMP REPLACEMENT
CAUTION
BEFORE REMOVING THE SCREW, DISCONNECT
POWER CORD. HOT SURFACE INSIDE
ALLOW 1 HOUR TO COOL BEFORE REPLACING
THE LAMP.
REPLACE WITH SAME SHARP LAMP
UNIT TYPE BQC-XGP25X//1 ONLY.
UV RADIATION : CAN CAUSE EYE DAMAGE.
TURN OFF LAMP BEFORE SERVICING.
MEDIUM PRESSURE LAMP : RISK OF EXPLOSION.
POTENTIAL HAZARD OF GLASS PARTICLES IF
LAMP HAS RUPTURED. HANDLE WITH CARE.
SEE OPERATION MANUAL.