    3-815-910-11 (1) Network Camera User's Guide Software Version 1.0 SNC-CS3N/CS3P © 2003 Sony Corporation
  • Sony SNC-CS3N | User Guide - Page 2
    your Sony dealer regarding this product. Model No Serial No WARNING To prevent fire or shock hazard, do not expose the unit to rain or moisture. To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only. Power Supply Caution for U.S.A. and Canada The SNC-CS3N
  • Sony SNC-CS3N | User Guide - Page 3
    Sony Customer Information Services Center 6900-29, Daniels Parkway, PMB 330 Fort Myers, Florida 33912 Declaration of Conformity Trade Name: SONY Model No: SNC-CS3N Responsible Party: Sony NOTICE TO USERS © 2003 Sony Corporation. All rights reserved. This manual or the software described herein,
  • Sony SNC-CS3N | User Guide - Page 4
    20 Camera setting Section 20 Configuring the Network - Network setting Page 22 Wired LAN setting Section 22 HTTP port setting Section 23 Notifying the IP Address - Dynamic IP address notification Section ...23 Setting the User - User setting Page 25 Setting the Security - Security setting
  • Sony SNC-CS3N | User Guide - Page 5
    Using the Setup Program 42 Changing the Communication Bandwidth ....... 44 Setting the Date and Time 44 Rebooting the Camera 45 Assigning the IP Address to the Camera Using ARP Commands 45 Using the SNMP 46 1. Inquiry Commands 46 2. Setting Commands 46 Storing an HTML File in the Built
  • Sony SNC-CS3N | User Guide - Page 6
    using the Web browser on the computer connected to the 10BASE-T or 100BASE-TX network. The maximum frame rate is 30 FPS for the SNC-CS3N and 25 FPS for the SNC-CS3P. Up to 50 users can view the image from one camera at the same time. Available Web browsers Microsoft Internet Explorer Ver. 5.5 or
  • Sony SNC-CS3N | User Guide - Page 7
    How to Use This User's Guide This User's Guide explains how to operate the SNCCS3N/CS3P Network Camera from a computer. The User's Guide is written to be read on the computer display. As this section gives tips on using the User's Guide, read it before you operate the camera. Jumping to the related
  • Sony SNC-CS3N | User Guide - Page 8
    Options and Security tab in sequence. 2 Click the Internet icon (when using the camera via the Internet) or Local intranet icon (when using the camera via a local network). 3 Set the slider to Medium or lower. (If the slider is not displayed, click Default Level.) When using antivirus software in
  • Sony SNC-CS3N | User Guide - Page 9
    Sun HomePage, and install it following the instructions on the installer. Then select Tool from this software. When you log in the camera using Internet Explorer for the first time, the Security Warning the Proxy server manually. For setting the Proxy server, consult your network administrator. •
  • Sony SNC-CS3N | User Guide - Page 10
    camera and stores it in the computer. (See "Capturing a Monitor Image" on page 13.) Trigger Displays the trigger control parts on the image control section. By clicking the trigger button, you can control various applications manually. (See "Controlling the Application Manually" on page 12.) User
  • Sony SNC-CS3N | User Guide - Page 11
    frame rate is 30 FPS for the SNC-CS3N and 25 FPS for the SNC-CS3P. Note The frame rate options indicate the maximum number of frames that can be transmitted. The number of frames actually transmitted may vary depending on the network environments and camera settings (image size and image quality
  • Sony SNC-CS3N | User Guide - Page 12
    Operating the Camera Controlling the Application Manually You can send an image or output a trigger to control the alarm output, using the image control section on the main viewer page. For this function, user access right Level 3 or Level 4 is required (see page 25). Click Trigger on the menu
  • Sony SNC-CS3N | User Guide - Page 13
    Operating the Camera Capturing a Monitor Image If you click the Capture button on the menu section, the current still image is captured and displayed on the monitor image
  • Sony SNC-CS3N | User Guide - Page 14
    not installed, install it following the manual supplied with the Pocket PC. Logging in to Homepage - Welcome Page 1 Start the web browser on the Pocket PC and type the IP address of the camera you want to monitor. The welcome page of Network Camera SNC-CS3 is displayed. 2 Tap [Viewer]. Operating
  • Sony SNC-CS3N | User Guide - Page 15
    the button changes to Stop. Tap to stop the viewer operation. The image refreshment stops. The name of the button changes to Start. Operating the Camera Using a Pocket PC Monitor image section Image control section Monitor Image Section If you set the Image size menu on the
  • Sony SNC-CS3N | User Guide - Page 16
    "Setting the Camera - Camera setting Page" on page 20. Network Displays the Network setting page. See "Configuring the Network - Network setting Page" on page 22. User Displays the User setting page. See "Setting the User - User setting Page" on page 25. Security Displays the Security setting page
  • Sony SNC-CS3N | User Guide - Page 17
    to perform the principal settings of the software. System setting Section Click this button to 10 seconds before turning off the power of the camera. If the power is turned off immediately, the changed page may change for a while. This is not a problem. Title bar name Type a name to display on the
  • Sony SNC-CS3N | User Guide - Page 18
    SNC-CS3N and 25 FPS for the SNC-CS3P. Note To update the main viewer page for the changed setting, click Refresh of the browser. Default URL Select the homepage to be displayed when you enter the IP address of the camera shows the software version and troubleshooting information. Access log
  • Sony SNC-CS3N | User Guide - Page 19
    . Note The IP address setting in the Wired LAN setting section (see page 22) on the Network setting page cannot be set. Reboot Reboots the camera. Click Reboot, and "The SNC-CS3 will be rebooted. Are you sure?" appears. Click OK to reboot the camera. Factory default Resets the camera to the factory
  • Sony SNC-CS3N | User Guide - Page 20
    the Image size menu to 736 × 480 or 640 × 480 for the SNC-CS3N, or 736 × 544 or 640 × 480 for the SNC-CS3P. 2 Set the Area setting menu to On, and click Apply. 3 Click the Area setting button. A still image is displayed. 4 Specify the trimming portion. 20 Setting the Camera - Camera setting Page
  • Sony SNC-CS3N | User Guide - Page 21
    Automatic Gain Control). Administrating the Camera Red trimming Click the left Manual. The setting items required for each setting appear. Shutter Select the electronic shutter speed from among the following: SNC-CS3N: 1/10000, 1/4000, 1/2000, 1/1000, 1/500, 1/250, 1/100, 1/60 (seconds). SNC-CS3P
  • Sony SNC-CS3N | User Guide - Page 22
    or not. Select On to assign the IP address of the DNS server automatically. IP address Type the IP address of the camera. Subnet mask Type the subnet mask. Default gateway Type the default gateway. MAC address Displays the MAC address of the camera. 22 Configuring the Network - Network setting Page
  • Sony SNC-CS3N | User Guide - Page 23
    and 65535. Note When you have set the HTTP port No. to a number other than 80 on the Network setting page or in the Setup Program, access the camera by typing the IP address of the camera on the web browser, as follows: Example: when HTTP port No. is set to 8000 Notifying the
  • Sony SNC-CS3N | User Guide - Page 24
    IP IP address you have acquired by the DHCP, in the text or parameter. Use this tag to embed the camera's model name (SNCCS3N or SNC-CS3P) in the text or parameter. Use this tag to embed the camera's serial number in the text or parameter. 24 Configuring the Network - Network
  • Sony SNC-CS3N | User Guide - Page 25
    the Camera Setting the User - User setting Page When you click User on the Administrator menu, the User setting page appears. Use this page to set the user names and passwords of Administrator and up to 9 kinds of users (User 1 to User 9), and the access right of each user. Administrator, User 1 to
  • Sony SNC-CS3N | User Guide - Page 26
    -Securing setting Page Network address/Subnet 1 to Network address/Subnet 10 Type the IP addresses and subnet mask values you want to allow or deny access to the camera. You can specify up to 10 IP addresses and subnet mask values. For a subnet mask, type 8 to 32. To temporarily cancel the Default
  • Sony SNC-CS3N | User Guide - Page 27
    Camera activity detection function or a manual trigger button, or capture IP address of the FTP server. User name Type the user name for the FTP server. Password Type the password for the FTP server. Re-type password To confirm the password, type the same characters as you typed in the Password
  • Sony SNC-CS3N | User Guide - Page 28
    Administrating the Camera Mode Select the mode of the FTP client function. Manual: Sends still images to the FTP server manually. After selecting Manual, click OK. The FTP client function mode is set to Manual. In this mode, when you click the (Trigger) button on the main viewer page, a still image
  • Sony SNC-CS3N | User Guide - Page 29
    memory space. Log Click View to display the Backup FTP log page to show network failures and event information. Click Clear to delete the log contents. Note The log contents are cleared when the power of the camera is turned off. Operating the Digest Viewer If you download the HTML file, the
  • Sony SNC-CS3N | User Guide - Page 30
    Use this page to set up for the FTP server function which finds a specified still image file stored in the built-in memory of the camera (about 8 MB) or download the still image file. Activating/Deactivating the FTP Server Function - FTP server usage setting Page To activate the FTP server function
  • Sony SNC-CS3N | User Guide - Page 31
    user names and passwords to allow logging in the camera using the FTP client software of the computer. Built-in memory Displays the free space of the built-in memory of the camera. User ID Type a user name between 4 and 16 characters. Password Type a password function or a manual trigger button. The
  • Sony SNC-CS3N | User Guide - Page 32
    Administrating the Camera SMTP server name Type the SMTP server name up to 64 characters, or the IP address of the SMTP server. a still image is captured and sent via an E-mail. (See "Controlling the Application Manually" on page 12.) Alarm: Sends a still image via an E-mail by synchronizing with
  • Sony SNC-CS3N | User Guide - Page 33
    the alarm out 1 or alarm out 2 of the I/O port located on the rear the camera. You can control the alarm out when a trigger occurs by an external sensor input, the built-in activity detection function, a manual trigger button or the timer. The setting items for alarm out 1 and alarm out 2 are
  • Sony SNC-CS3N | User Guide - Page 34
    is detected, the alarm out 1 status changes. Sensor: External sensor connected to sensor input of the camera I/O port Activity detection: The activity detection function built in the camera. To set the activity detection function, click Activity detection. The Activity detection setting page appears
  • Sony SNC-CS3N | User Guide - Page 35
    by an external sensor input, the built-in activity detection function or a manual trigger button. The captured still image is recorded in the built-in memory recorded in the built-in memory will be erased when the power of the camera is turned off. • The frame rate and operability on the main viewer
  • Sony SNC-CS3N | User Guide - Page 36
    address menus appear. SMTP server name Type the name or IP address of the SMTP server you want to use for recorded in the memory. (See "Controlling the Application Manually" on page 12.) Alarm: Records a still camera I/O port Activity detection: The activity detection function built in the camera
  • Sony SNC-CS3N | User Guide - Page 37
    Administrating the Camera Periodical recording mode setting Section Interval time Type the alarm modes. The Timer folder corresponds to the periodical recording mode. And, the Manual folder corresponds to the manual mode. JPEG image files are stored in each folder. If the digest viewer is
  • Sony SNC-CS3N | User Guide - Page 38
    can select from among the following intervals: SNC-CS3N: 1/30, 1/15, 1/10, 1/5, 1/2, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 (seconds) SNC-CS3P: 1/25, 1/12, 1/8, 1/5, 1/2, interface. You can input data from a computer via the network to the camera, and output it to an external serial interface for controlling
  • Sony SNC-CS3N | User Guide - Page 39
    days of the week that you want to activate the function. OK/Cancel See "Buttons common to every setting page" on page 17. Administrating the Camera 39 Setting the Schedule - Schedule setting Page
  • Sony SNC-CS3N | User Guide - Page 40
    activity detection working area as follows: 1 Determine the view angle of the camera at which you want to perform activity detection, using the zoom. 2 with a red frame determines the activity detection working area. As the default setting, the whole area is set as the activity detection working area
  • Sony SNC-CS3N | User Guide - Page 41
    on the computers monitoring the camera image, or for displaying a pop-up automatically when there is an alarm input. Manual pop-up text Type the computer monitoring the camera image as the Administrator. All users: The pop-up is displayed on all the computers monitoring the camera image. Sensor
  • Sony SNC-CS3N | User Guide - Page 42
    the wizard displayed. If the Software License Agreement is displayed, read it carefully and accept the agreement to continue the installation. 5 Start the IP Setup Program. The program detects the SNC-CS3 cameras connected to the local network and lists them on the Network tab window. 6 Click on
  • Sony SNC-CS3N | User Guide - Page 43
    To specify the IP address manually: Select Use the following IP address, and type the IP address, Subnet mask and Default gateway in each box. Note You cannot change the Administrator name and Administrator password in this step. To change these items, See "Setting the User - User setting Page" on
  • Sony SNC-CS3N | User Guide - Page 44
    the desired bandwidth from the Setting bandwidth list box. 3 Type the Administrator name and Administrator password in each box. 4 Click OK. If "Setting OK" is displayed, the bandwidth setting is completed. 2 Click to select the camera you want to set the date and time for. You can select multiple
  • Sony SNC-CS3N | User Guide - Page 45
    was turned on? If not, turn off the camera and restart the operation. - Is the NETWORK indicator on the camera flashing? If the indicator goes off, the network connection has a problem. Connect the network correctly. - Did you enter the IP address previously used for another device? Assign a new
  • Sony SNC-CS3N | User Guide - Page 46
    supports SNMP (Simple Network Management Protocol). You can read MIB-2 objects and write some MIB-2 objects using software such as SNMP manager software. This unit also supports ="\"SONY Network Camera SNC- CS3\"" public, and enables read from any IP address (0.0.0.0). 8 describes the community name
  • Sony SNC-CS3N | User Guide - Page 47
    describes the community name to send traps to, and describes the IP address of the host to send traps to. Example: To specify the the following CGI command. Be careful that by entering the command, the camera enters the restart mode. SNMP restart command GET, POST
  • Sony SNC-CS3N | User Guide - Page 48
    . boxes. Note If you cannot establish communication with the camera with the proxy server being used, connect the camera to the local network and run the installer without using the proxy server. 9 Type the Administrator name and Administrator password. Others 48 Storing an HTML File in the Built
  • Sony SNC-CS3N | User Guide - Page 49
    10 Confirm that all items are correct, then click Next. The following page will appear after a while. The camera will be restarted automatically in two minutes, and storing to the built-in flash memory is completed. 11 Type the path for the folder in
  • Sony SNC-CS3N | User Guide - Page 50
    22 main viewer page 10, 15 memory 35 menu section 10 monitor image section 11, 15 monochrome 20 N network configuration 22 NTP server 19 O OK button 17 overwrite 35 P parity bit 39 password 25 PDA 14 pocket PC 14 pop-up 41 port number 23 post-alarm 38 pre-alarm 38 proxy
  • Sony SNC-CS3N | User Guide - Page 51
    Others T TCP 38 TCP port 38 time difference 18 title 23 title bar 17 trigger control parts 12 trimming 20 U URL 18 user authentication 25 user name 25 user setting 25 V view size 11 viewer 9 W welcome page 8, 14, 17 white balance mode 21 Index 51
  • Sony SNC-CS3N | User Guide - Page 52
    Sony Corporation
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

3-815-910-
11
(1)
Network Camera
© 2003 Sony Corporation
SNC-CS3N/CS3P
User’s Guide
Software Version 1.0