TASCAM CD-400U RS-232C/TELNET Protocol Specifications

TASCAM CD-400U Manual

TASCAM CD-400U manual content summary:

  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 1
    X RS-232C/TELNET Protocol Specifications Ver. 1.20 CD-400U/CD-400UDAB TASCAM CD-400U/CD-400UDAB CONTROL I/O Terminals RS-232C/TELNET Protocol Specifications Ver. 1.20 Jun/2022 TEAC Corporation - 1 -
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 2
    with the covered TASCAM products. 3. The acquisition of this document by the customer does not mean that the customer has acquired any rights, titles or interests in this protocol other than what is specified in this use agreement. The customer should recognize that as a written work belonging to
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 3
    Standard: JIS X-5101 (equivalent to the former JIS-C-6361 and EIA RS-232C standards) Note that this is not compatible with the RS-422 used in professional VTRs. Impedance at receiver: When measured with an applied voltage between -3 V and +3 V or between -15 V and +15 V, the DC resistance is
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 4
    X RS-232C/TELNET Protocol Specifications Ver. 1.20 2.3. Connector pin-out Connector D-sub 9pin female (Inch screw thread) CD-400U/CD-400UDAB Terminal pin-out and input/output signals Pin No. In/Out Signal name Description 1 - NC Not connected 2 In Rx DATA Data received at this pin
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 5
    ) to 98 bytes, maximum. For detailed information about data, see each of the sections explaining commands. Note that capital letters are used for "A to F" for commands that use 0 to 9 and A to F as data values. Command examples Example 1: Sending the PLAY command to the controlled device with the
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 6
    two-byte ASCII. For details on the data, refer to the detailed explanation for each command. For commands that use 0--9 and A--F as data values, uppercase characters are used for A--F. Command examples Example 1: Sending a PLAY command to a controlled device with Machine ID = 0 When stopped or in
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 7
    . Examples of command sequences are shown below. Make sure that commands are sent at a minimum of 100-millisecond intervals. Example 1: Using a transport control of the controlled device (e.g. playback) When entering the playback state after receiving the playback command, the controlled device
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 8
    79 CAUTION SENSE F9 CAUTION SENSE RETURN 7F VENDOR COMMAND FF VENDOR COMMAND RETURN Caution: If no supported version is indicated in the "Adopted F/W Ver." column, ver. 1.00 or later are supported. List of vendor commands The list of vendor commands (Command 7F/FF) is as follows. Their command
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 9
    X RS-232C/TELNET Protocol Specifications Ver. 1.20 CD-400U/CD-400UDAB 3.5. Command Details INFORMATION REQUEST INFORMATION REQUEST requests the controlled device to return information including the software version of the controlled device. Command Data Return 0F None INFORMATION RETURN [8F]
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 10
    X RS-232C/TELNET Protocol Specifications Ver. 1.20 CD-400U/CD-400UDAB READY READY puts the controlled device into playback standby mode. Command 14 Data 2 bytes Return None Data 1 0 Data 2 1 Description Ready ON Remarks Switches to playback standby mode. ·If the controlled device
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 11
    X RS-232C/TELNET Protocol Specifications Ver. 1.20 CD-400U/CD-400UDAB TRACK SKIP SKIP allows the controlled device to skip a track. If the mode is FM or AM and a preset number is not displayed (Frequency mode), this command changes the received frequency. If the mode is FM or AM and a preset
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 12
    X RS-232C/TELNET Protocol Specifications Ver. 1.20 CD-400U/CD-400UDAB RESUME PLAY SELECT RESUME PLAY SELECT turns the resume play mode of the controlled device on or off. Only when this command is sent with request data [FF], the controlled device sends the REPEAT SELECT RETURN command [B4].
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 13
    X RS-232C/TELNET Protocol Specifications Ver. 1.20 CD-400U/CD-400UDAB CLEAR CLEAR replies no or cancel when a message is displayed. (Same as CLEAR button) Command: Data: Return: 4A None None REMOTE/LOCAL SELECT REMOTE/LOCAL SELECT enables or disables key operation on the controlled device. Only
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 14
    PLAY MODE SELECT PLAY MODE SELECT sets the playback mode of the controlled device. The playback mode setting can be checked using the PLAY MODE SENSE command [4E]. Command 4D Data 2 bytes Return None Data 1 Data 2 Description 0 0 Continuous 0 1 Single 0 6 Random Remarks Continuous
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 15
    on the media (02) and Total remaining time on the media (03) are not supported when the media is Data-CD, USB or SD. Command 58 Data 2 bytes Return CURRENT occurred on the controlled device. Be sure to determine the error by using this command if the ERROR SENSE REQUEST command [F0] is issued
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 16
    X RS-232C/TELNET Protocol Specifications Ver. 1.20 CD-400U/CD-400UDAB INFORMATION RETURN INFORMATION RETURN is sent in response to the INFORMATION REQUEST command [0F] to show the software version. Command 8F Data 4 bytes Request command INFORMATION REQUEST [0F] Data 1 Description Tens
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 17
    X RS-232C/TELNET Protocol Specifications Ver. 1.20 CD-400U/CD-400UDAB INCR PLAY SELECT RETURN INCR PLAY SELECT RETURN is sent in response to the INCR PLAY SELECT command [3A] to show the current incremental playback setting. Command Data Request command Data 1 Data 2 0 0 0 1 BA 2 bytes
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 18
    X RS-232C/TELNET Protocol Specifications Ver. 1.20 CD-400U/CD-400UDAB PLAY MODE RETURN PLAY MODE RETURN is sent in response to the PLAY MODE SENSE command [4E] to show the current playback mode setting. Command Data Request command Data 1 Data 2 0 0 0 1 0 6 CE 2 bytes PLAY MODE SENSE [
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 19
    (AM) Tenths digit of the frequency (MHz) (FM) Tens digit of the service number (DAB) Data 9 Tens digit of the seconds Ones digit of the frequency (kHz) (AM) Hundredths digit (MHz) (FM) Ones digit of the service number (DAB) Data 10 Ones digit of the seconds Reserved. Always 0 (AM/
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 20
    digit of the seconds Ones digit of the seconds (Tens digit of the frame) (Ones digit of the frame) 01, 02 and 03 are not supported when the media is Data-CD, USB or SD, When the media is CD-DA and Play mode is random, 02 and 03 is not
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 21
    Tens digit of the total number of frames of all tracks) Frames are not supported. Data (Ones digit of the total number of frames of all tracks) 11 the ERROR SENSE command [78]. Be sure to determine the error by using the ERROR SENSE command. Command Data Request command F0 None None CAUTION SENSE
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 22
    X RS-232C/TELNET Protocol Specifications Ver. 1.20 CD-400U/CD-400UDAB ILLEGAL STATUS ILLEGAL STATUS is sent from the controlled device to the external controller to show that an invalid command or data has been sent to the controlled device. If the command is sent, send a command or data again,
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 23
    X RS-232C/TELNET Protocol Specifications Ver. 1.20 CD-400U/CD-400UDAB CAUTION SENSE RETURN CAUTION SENSE RETURN is sent in response to the CAUTION SENSE command [79]. Command F9 Data 4 bytes Request command CAUTION SENSE [79] Data 1 Data 2 Data 3 N2 CAUTION CODE(N1-N2N3) N3 0-00 No
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 24
    '7F' or 'FF' Category Code Sub Command Parameter ... LF CR Category Code: Sub Command: Parameter: The category code (2-byte ASCII) is used for classifying vendor commands according to function. This is a unique sub-command code (2-byte ASCII) within the category. DEVICE SELECT (01), DIVIDE(02
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 25
    sets the playback area of the controlled device. This command is not supported when the media is CD-DA. Command Category Code Subcommand Parameter: Sense If the source is CD-DA, it sends ILLEGAL [F2]. ENTER ENTER works as same as pressing the main unit MULTI JOG dial or remote control ENTER button
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 26
    selected. PLAY AREA SELECT RETURN PLAY AREA SELECT RETURN is sent in response to the PLAY AREA SELECT command [7F074F]. This command is not supported when the media is CD-DA. Command FF Category Code 07 Subcommand CF Parameter: 2 bytes Request command PLAY AREA SELECT [7F074F] Data 7 Data
  • TASCAM CD-400U | RS-232C/TELNET Protocol Specifications - Page 27
    X RS-232C/TELNET Protocol Specifications Ver. 1.20 CD-400U/CD-400UDAB Revision List Ver. 1.00 First issue Ver. 1.01 Change 7F01 "DEVICE SELECT" and FF01 "DEVICE SELECT RETURN" Delete Subcommand 32 DAB Change Subcommand 30: FM  FM for CD-400U / DAB for CD-400UDAB Change Subcommand 31: AM  AM for
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

X
RS-232C/TELNET Protocol Specifications
Ver. 1.20
CD
-
400U/CD
-
400UDAB
-
1
-
TASCAM CD-400U/CD-400UDAB
CONTROL I/O Terminals
RS-232C
TELNET Protocol Specifications
Ver. 1.20
Jun/2022
TEAC Corporation