. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 3
Don't disassemble the product, or make repairs yourself. You run the risk of electric shock and voiding the limited warranty. If you need service, please contact us. • Avoid water and wet locations. BSMI Notice Industry Canada Statement CAN ICES-3 (A)/NMB-3(A) Explanation of the symbols on the - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 4
of the switch. Chapter 5 Configuration. This chapter instructs you to configure the switch via Web Interface and CLI commands. Appendix A Troubleshooting. Appendix B Hardware Specifications. Audience This Installation Guide is for: Network Engineer Network Administrator Conventions ■■ The - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 5
13 4.4 Verify Installation 14 4.5 Power On 15 4.6 Initialization 15 Chapter 5 Configuration----------- 16 5.1 Configure the Switch via GUI 16 5.2 Configure the Switch Using CLI 17 Appendix A Troubleshooting--------- 20 Appendix B Hardware Specifications------ 22 Contents IV - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 6
, designed for workgroups and departments, provides wire-speed performance and abundant layer 2 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 7
RJ45 port has a corresponding 10/100/1000M LED. SFP Port Designed to install the SFP module. T2500G-10TS features 2 individual SFP ports and supports 1000M SFP module connection only. ■■ Rear Panel The rear panel of T2500G-10TS is shown as the following figure. Kensington Security Slot Grounding - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 8
L2 Managed Switch Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed information, please refer to Chapter 3 Lightning Protection. Power Socket Connect - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 9
, one Console This Installation Guide Cable and one USB Cable Business Networking Solution Installation Guide One Resource CD Two mounting liquid cleaning method. ■ Site Requirements To ensure normal operation and long service life of the device, please install it in an environment that meets - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 10
, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device. For normal temperature and humidity of the device, please check the following table. Environment Operating Storage - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 11
following items: ■ The rack or workbench is flat and stable, and sturdy enough to support the weight of 5.5kg at least. ■ The rack or workbench has a good ventilation below: 1. Set the device on a flat surface strong enough to support the entire weight of the device with all fittings. 2. Remove the - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 12
of the Device Notch Figure 2-1 Desktop Installation ■ Rack Installation To install the device in an EIA standard-sized, 19-inch rack, follow the instructions described below: 1. Check the grounding and stability of the rack. 2. Secure the supplied rack-mounting brackets to each side of the device - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 13
L2 Managed Switch Chapter 3 Lightning Protection 3.1 Cabling Reasonably In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devices - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 14
L2 Managed Switch ■■ Requirements for the distance between Ethernet cable and other pipelines are shown in the table. Other Pipelines Down-conductor PE Service pipe Compressed air pipe Thermal pipe (not wrapped) Thermal pipe (wrapped) Gas pipe Min Parallel Net Length L (mm) 1000 50 150 150 500 - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 15
, which is also a necessary measure to protect the body from electric shock. In different environments, the device may be grounded differently. The following will instruct you to connect the device to the ground in two ways, connecting to the grounding bar or connecting to the ground via the power - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 16
L2 Managed Switch Note: ■ The figure is to illustrate the application and principle. The power cord you get from the package and the socket in your situation will comply with the regulation in your country, so they may differ from the figure above. ■ If you intend to connect the device to the ground - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 17
L2 Managed Switch Note: Power lightning arrester is not provided with our product. If needed, please purchase it. Signal lightning arrester is used to protect RJ45 ports of the device from lightning. When cabling outdoors, please install a signal lightning arrester before connecting the cable to the - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 18
L2 Managed Switch Chapter 4 Connection 4.1 Ethernet Port Connect the Ethernet ports of the switch to the network devices by RJ45 cable as the following figure shows. RJ45 Port RJ45 Cable Figure 4-1 Connecting the RJ45 Port 4.2 SFP Port Connect the SFP port to an SFP module. For the switch, if an - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 19
) Figure 4-4 Connecting the Console (USB) Port You can also manage the device through the console port, for details please refer to the CLI Reference Guide on the resource CD. Note: ■ Console (RJ-45) port and Console (USB) port cannot be used concurrently. Console (USB) port takes priority over the - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 20
L2 Managed Switch 4.5 Power On Plug the female connector of the provided power cord into the power socket of the device, and the male connector into a power outlet as the following figure shows. 2 1 Figure 4-5 Connecting to Power Supply Note: The figure is to illustrate the application and principle - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 21
L2 Managed Switch Chapter 5 Configuration 5.1 Configure the Switch via GUI Note: To log on to the GUI of the switch, the IP address of your PC should be set in the same subnet addresses of the switch. The IP address is 192.168.0.x ("x" is any number from 2 to 254), Subnet Mask is 255.255.255.0. 1. - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 22
time on a Windows-based PC The driver can be found on the attached CD and Download page of our official website. Refer to the User Guide to learn more about the installation. To log on to the switch by the console port on the switch, please take the following steps: 1. Connect - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 23
now. ■■ Logon by Telnet Figure 5-4 Log in the Switch To log on to the switch by a Telnet connection, please take the following steps: 1. The switch supports two access mode, login local mode (the default mode) and login mode. Here we take login local mode as an example. 2. Make sure the switch - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 24
are admin), then press the Enter button so as to enter User EXEC Mode. Figure 5-7 Enter into the User EXEC Mode For detailed CLI configuration instructions, please refer to the CLI Reference Guide on the resource CD. 19 Configuration - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 25
L2 Managed Switch Appendix A Troubleshooting Q1. What could I do if I forgot the username and password of the switch? 1. Connect the console port of the PC sure the power supply is normal and the console cable is properly connected. 2. Check if the console cable is the right type. Troubleshooting 20 - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 26
L2 Managed Switch 3. Ensure the parameters of the hyper terminal are correct: configure Bits per second as 38400, Data bits as 8, Parity as None, Stop bits as 1, and Flow control as None. 21 Troubleshooting - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 27
L2 Managed Switch Appendix B Hardware Specifications Item Content IEEE 802.3i 10Base-T Ethernet IEEE 802.3u 100Base-TX/100Base-FX Standards IEEE 802.3ab 1000Base-T IEEE 802.3z 1000Base-X IEEE 802.3x Flow Control 10Base-T: UTP/STP of Cat. 3 or above 100Base-TX: UTP/STP of Cat. 5 or above - TP-Link T2500G-10TSTL-SG3210 | T2500G-10TSUN V1 Installation Guide - Page 28