TP-Link T3700G-28TQ T3700G-28TQ V1 IG

TP-Link T3700G-28TQ Manual

TP-Link T3700G-28TQ manual content summary:

  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 1
    Business Networking Solution Installation Guide Stackable L3 Managed Switch T3700G-28TQ
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 2
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 3
    without permission from TP-LINK TECHNOLOGIES CO., LTD. Copyright © 2014 TP-LINK TECHNOLOGIES CO., LTD. All rights reserved. http://www.tp-link.com FCC and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 4
    ://www.tp-link.com About this Installation Guide This Installation Guide describes the switch. Chapter 6 Configuration. This chapter instructs you to configure the switch via Web Interface and CLI commands. Appendix A Troubleshooting. Appendix B Hardware Specifications. Appendix C Technical Support
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 5
    the specific formats to highlight special messages. The following table lists the notice icons that are used throughout this guide. Remind to be careful. A caution indicates a potential which may result in device damage. Remind to take notice. The note contains the helpful information for a better
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 6
    Safety Precautions 05 2.3 Installation Tools 07 2.4 Installation & Connection Flow 07 Chapter 3 Installation 09 3.1 Installing the Switch on a Desktop 09 3.2 Installing the Switch Into a 19-inch Rack............09 3.3 Installing & Removing the Power Supply Module...10 3.4 Installing & Removing
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 7
    Appendix A Troubleshooting----------- 29 Appendix B Hardware Specifications------- 30 Appendix C Technical Support---------- 31 Contents V
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 8
    1111 Product Overview T3700G-28TQ is TP-LINK's JetStream Stackable L3 Managed Switch, supporting up to 4 SFP+ slots. T3700G-28TQ is ideal for large businesses, campuses or SMB networks requiring an outstanding, reliable and affordable 10 Gigabit solution. T3700G-28TQ supports stacking of up
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 9
    system On(green1 An Interface Card is connected to the switch and works properly Module An Interface Card is connected to the switch, but Flashing(yellow1 works improperly Off No Interface Card is connected to the switch Link/Act (Port 1-241 Green Yellow On Flashing On Flashing A 1000Mbps
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 10
    or SFP+ cables. T3700G-28TQ also provides an interface card slot on the rear panel to install the expansion card (TX432 of TP-LINK for example). If TX432 is installed, you get another two 10Gbps SFP+ ports. Unit ID LED Designed to display the stack unit ID of the switch. For the switch that does not
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 11
    (Redundant Power Supply). You can selected an RPS (RPS150 of TP-LINK for example) for your switch if needed. For how to install an RPS, please refer to TX432) & Power Supply Module (PSM150-AC) inserted, the rear panel of T3700G-28TQ is shown as the following figure. Module TX432 M1 SFP+ M2 SFP+
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 12
    One Switch O n e Po w e r C o rd a n d o n e This Installation Guide Console switch. ■■ Before cleaning the device, cut off the power supply. Do not clean it by the waterish cloth, and never use any other liquid cleaning method. ■■ Site Requirements To ensure normal operation and long service
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 13
    of the insulation materials and can thus significantly shorten the service life of the device. For normal temperature and humidity circuit board. To avoid the effect of static electricity on the operation of the switch, please attach much importance to the L5428E following items: ■■ Dust the device
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 14
    items: ■■ The rack or workbench is flat and stable, and sturdy enough to support the weight of 5.5kg at least. ■■ The rack or workbench has a good ventilation Flow T3700G-28TQ provides interfaces to install the swappable Power Supply Module, Interface Card and Redundant Power Supply. The switch is
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 15
    to SFP/SFP+ transceivers and cables Also power on via No RPS? Yes Connect to RPS End FFFFFFFFFFFFInstallation & Connection Flow Note: The switch can be powered by the Power Supply Module and Redundant Power Supply simultaneously or individually. If simultaneously, the Power Supply Module and
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 16
    on the bottom at each corner of the switch. FFFFFFFFFFFFDesktop Installation Feet Bottom of the Device Notch 3333Installing the Switch Into a 19-inch Rack To install the switch in an EIA standard-sized, 19-inch rack, follow the instructions described below: 111 Check the grounding and stability
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 17
    mounting screws of the protective cover on the power supply module slot of the switch and remove the protective cover, as shown in the following figure. FFFFFFFFFFFFRemoving the in along the slot guide rail until the module is flush with the switch, as shown in the following figure. Installation 10
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 18
    all spring pressure is released. 444 Pull the handle by one hand towards you along the guide rails, and hold the bottom of the module by the other hand, until it completely comes out of the switch chassis. Note: When installing or removing a power supply module, pay attention to the following points
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 19
    at both sides of the interface card until all spring pressure is released. 333 Pull the interface card towards you along the guide rails, until it completely comes out of the switch chassis. Note: ■■ TX432 supports hot plug, so if necessary you can install or remove the interface card when the
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 20
    Interface), use a console cable to connect the PC to the console port of any switch in the stack. This single console connection enables you to manage all the switches in the stack. Caution: In the process of using TP-LINK SFP+ Cables, please never bend them into a radius of 45mm (1.77 inch) or
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 21
    Stackable L3 Managed Switch CCCCCCCCCCCLightning Protection 4444 Cabling Reasonably In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 22
    Stackable L3 Managed Switch ■■ Requirements for the distance between Ethernet cable and other pipelines are shown in the table. Ethernet Cable Other Pipelines Min Parallel Net Length Min Parallel-overlapping Net Height L (mm1 H (mm1 Down-conductor 1000 300 PE 50 20 Service pipe 150 20
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 23
    different environments, the device may be grounded differently. The following will instruct you to connect the device to the ground in two ways, connecting PS OK Fault PSM150-AC 100-240V~ 50/60Hz 2.5A Switch (Rear Panel) Ground Cable Grounding Terminal Grounding Bar FFFFFFFFFFFFConnecting to
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 24
    Stackable L3 Managed Switch Note: ■■ The figure is to illustrate the application and principle. The power cord you get from the package and the socket in your situation will
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 25
    Stackable L3 Managed Switch 4444Use Lightning Arrester Power lightning arrester and signal lightning arrester are used for lighting protection. Power lightning arrester is used for limiting the voltage surge
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 26
    RJ45 Cable FFFFFFFFFFFFConnecting the RJ45 Port 5555SFP Port Connect an SFP transceiver to the SFP port . For the switch, if an RJ45 port which is combo with SFP port has a valid link, the associated SFP port will be disabled and cannot be used. SFP Port SFP Transceiver FFFFFFFFFFFFInserting the
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 27
    Stackable L3 Managed Switch FFFFFFFFFFFFConnecting the Console Port You can also manage the device through the console port, for details please refer to the CLI Reference Guide on the resource CD. Note: ■■ The console port is the first port on the left of the front panel. ■■ Please keep the device
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 28
    below to connect the Redundant Power Supply (RPS150 for example) to T3700G-28TQ. 111 Confirm that the power supply of the RPS150 is cut off. 222 Remove the protective covers covering the redundant power socket of RPS150 and the switch, similar to the procedure shown in Figure 2-4. 333 Connect the
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 29
    Stackable L3 Managed Switch 5555Initialization After the device is powered on, it begins the Power-On Self-Test. A series of tests run automatically to ensure the device functions properly.
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 30
    IP address is 192.168.0.x ("x" is any number from 2 to 254), Subnet Mask is 255.255.255.0. 111 To access the GUI of the switch, open a web browser and type in the default management address http://192.168.0.1 in the address field of the browser, then press the Enter key.
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 31
    , please take the following steps: 111 Connect the PCs or Terminals to the console port on the switch by a provided cable. 222 Click Start→All Programs→Accessories→Communications→Hyper Terminal to open the Hyper Terminal as the following figure shown. FFFFFFFFFFFFOpen Hyper Terminal
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 32
    Stackable L3 Managed Switch 333 The Connection Description Window will prompt as Figure 6-5. Enter a name into the Name field and click OK. FFFFFFFFFFFFConnection Description 444 Select the port to
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 33
    T3700G-28TQ>" will appear after pressing the Enter button as Figure 6-8 shown. It indicates that you can use the CLI now. FFFFFFFFFFFFLog in the switch ■■ Logon by Telnet To log on to the switch Reference Guide on the resource CD. Here we take login local mode as an example. 222 Make sure the switch
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 34
    Stackable L3 Managed Switch FFFFFFFFFFFFOpen the Run window 444 Type in cmd in the prompt Run window as Figure 6-10 and click OK. FFFFFFFFFFFFFRun Window 555 Type in telnet
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 35
    of them is admin) and press the Enter button, then you can use the CLI now, which is shown as Figure 6-12. FFFFFFFFFFFFFLog in the switch For detailed CLI configuration instructions, please refer to the CLI Reference Guide on the resource CD. Configuration 28
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 36
    is normal. 222Make sure the voltage of the power supply meets the requirement of the input voltage of the switch. QQQQ What could I do if I could not access the web-based configuration page? You are recommended to as 8, Parity as None, Stop bits as 1, and Flow control as None. 29 Troubleshooting
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 37
    Stackable L3 Managed Switch AAAAAAAAAAAAHardware Specifications Item Content IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX/100Base-FX IEEE 802.3ab 1000Base-T Standards IEEE 802.3z 1000Base-X IEEE
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 38
    Switch AAAAAAAAAAAATechnical Support ■■ For more help, please go to: http://www.tp-link.com/en/support/faq ■■ To download the latest Firmware, Driver, Utility and User Guide, go to: http://www.tp-link.com/en/support/download ■■ For all other technical support : [email protected] Service time
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 39
    Switzerland Turkey UK Ukraine USA/Canada Stackable L3 Managed Switch Tel: +41 (01 848 800 998 (German Service1 Fee: 4-8 Rp/min, depending on rate of different time. E-mail: [email protected] Service time: Monday to Friday, 9:00 to 12:30 and 13:30 to 17:30. GMT+ 1 or GMT+ 2 (DST1 Tel: 0850 7244
  • TP-Link T3700G-28TQ | T3700G-28TQ V1 IG - Page 40
    Website: http://www.tp-link.com Tel: +86 755 26504400 E-mail: [email protected] 7106504527 REV1.0.0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Installation Guide
Stackable L3 Managed Switch
T3700G-28TQ
Business Networking Solution