- TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 1
User Guide Easy Smart Switch 1910012910 REV5.2.0 October 2020 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 2
CONTENTS About This Guide Intended Readers...1 Conventions...1 More Information...2 Introduction Product Overview...4 Logging Into the Switch...5 Managing System System...8 Overview...8 Supported Features...8 Configuring System Info...9 Viewing the System Information...9 Specifying the Device - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 3
Configuring LAG...32 Network Requirements...32 Configuration Steps...33 Appendix: Default Parameters...34 Monitoring Monitoring...36 Overview...36 Supported Features...36 Viewing Port Statistics...37 Configuring Port Mirror...39 Testing Cables...41 Configuring Loop Prevention...43 Appendix: Default - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 4
Configuring Basic QoS ...62 Configuring QoS in Port Based Mode...63 Configuring QoS in 802.1P Based Mode...64 Configuring QoS in DSCP/802.1P Based Mode...64 Configuring Bandwidth Control...65 Configuring Storm Control...67 Configuration Example for Basic QoS...69 Network Requirements...69 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 5
, refer to the Easy Smart Configuration Utility User Guide. Go to the website https://www.tp-link.com/support, search the model number of your switch, and you can find this guide on the product Support web page. Intended Readers This Guide is intended for network managers familiar with IT concepts - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 6
More Information ■■ The latest software and documentations can be found at Download Center at https://www.tp-link.com/support . ■■ The Installation Guide (IG) can be found where you find this guide or inside the package of the switch. ■■ The authentication information can be found where you find - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 7
Part 1 Introduction CHAPTERS 1. Product Overview 2. Logging Into the Switch - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 8
designed for Small Office and Home Office networks. The switch supports the following features: ■■ Traffic monitoring: Port mirroring, loop feature is only available on certain devices. To check whether your device supports this feature, refer to the datasheet. ●● PoE configuration is only available - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 9
.0.x ("x" ranges from 2 to 254), and subnet mask as 255.255.255.0. 4) Launch a web browser on your PC. The supported web browsers include, but are not limited to, the following types: ■■ IE 8.0, 9.0, 10.0, 11.0 ■■ Firefox 26.0, 27.0 Entering the IP Address of the Switch in the Browser User Guide 5 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 10
interface displays below. You can view the running status of the switch and configure the switch on this interface. Figure 2-3 Launching the Web Interface User Guide 6 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 11
Part 2 Managing System CHAPTERS 1. System 2. Configuring System Info 3. Configuring IP 4. Configuring LED (Only for Certain Devices) 5. Configuring User Account 6. Backing up and Restoring the Switch 7. Rebooting the Switch 8. Resetting the Switch 9. Upgrading the Firmware 10. Appendix: Default - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 12
the system parameters and features of the switch. 1.2 Supported Features System Info The System Info is mainly used the switch. You can set IP address of the switch manually or using DHCP. User Account Management User Account Management is tp-link.com to download the updated firmware. User Guide 8 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 13
menu System > System Info to load the following page. Specify a new device description for the switch, and click Apply. Figure 2-2 Specifying the Device Description User Guide 9 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 14
Follow these steps to configure the system IP address manually: 1) Select DHCP setting as Disable from the drop-down list. 2) Specify the IP address, subnet mask and default gateway. IP Address Specify the system IP of the switch. You can use this IP address to access the switch. User Guide 10 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 15
Managing System Subnet Mask Specify the subnet mask of the switch.. Default Gateway Specify the default gateway of the switch. 3) Click Apply. Configuring IP User Guide 11 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 16
(Only for Certain Devices) 4 Configuring LED (Only for Certain Devices) Note: LED configuration is only available on certain devices. To check whether your device supports this feature, refer to the actual web interface. With this function, you can turn on or turn off the LED with one click. Choose - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 17
varies among different devices. If your password fails to meet the requirement, check the prompt information. Confirm Password 2) Click Apply. Retype the new password. User Guide 13 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 18
file to your PC. Figure 6-1 Backing Up the Configuration Note: It will take several minutes to save the configuration file. Wait without any operation. User Guide 14 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 19
section, click Choose File to load the following page. Specify the configuration file path and select the configuration file. Figure 6-3 Choosing the Configuration File User Guide 15 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 20
avoid any damage, do not power down the switch while being restored. ●● After being restored, the current configuration of the switch will be lost. User Guide 16 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 21
the switch. Wait without any operation while the switch reboots. ●● To avoid any damage, do not power down the switch while the switch reboots. User Guide 17 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 22
damage, do not power down the switch during the reset. ●● After the switch is reset, all the settings will be restored to the default. User Guide 18 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 23
: 1) Click Choose File to load the following page. Specify the firmware file path and select the firmware to upgrade. Figure 9-2 Browsing the Firmware File User Guide 19 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 24
to upgrade. ●● To avoid damage, do not power down the switch while upgrading the firmware. ●● It is recommended to backup the configuration before upgrading. User Guide 20 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 25
settings of User Account are listed in the following table. Table 10-3 Default Settings of User Account Configuration Parameter New Username Default Setting admin User Guide 21 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 26
Part 3 Switching CHAPTERS 1. Switching 2. Configuring Ports 3. Configuring IGMP Snooping 4. Configuring LAG 5. Configuration Examples 6. Appendix: Default Parameters - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 27
setting, IGMP Snooping and LAG. 1.2 Supported Features The switch supports the following features about switching: Port network resources and impacting information security. Multicast, however, solves all the problems caused by unicast and broadcast. With multicast, the source only needs Guide 23 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 28
Multicast router Source Source Layer 2 switch Layer 2 switch Host A Receiver Host B Host C Receiver Host A Receiver Host B Host C Receiver Multicast packets LAG With LAG (Link Aggregation Group) function, you can aggregate multiple physical ports into a logical interface to increase - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 29
. When Auto is selected, the port automatically negotiates speed mode with the connected device. It is recommended to select Auto if both ends of the link support autonegotiation. User Guide 25 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 30
period of time, thus avoiding the packet loss caused by congestion. 2) Click Apply. Note: ●● It is recommended to set the ports on both ends of a link with the same speed and duplex mode. ●● Keep the port that is connected to the management device enabled, or you cannot access the switch. ●● The - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 31
group. All port members of a multicast group should be included in the same VLAN. Ports Displays the forwarding port list of the multicast group. User Guide 27 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 32
click Delete to delete ports from the LAG group. Group ID Displays the ID of the LAG group. Ports Displays the LAG member ports. User Guide 28 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 33
configuring the other functions for the member ports. ●● Ensure that devices on both ends of the aggregation link use the same number of physical ports with the same speed and duplex mode, flow control setting and Each LAG group has 2 port members at least and 4 port members at most. User Guide 29 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 34
2 Host D Receiver 5.1.2 Configuration Scheme ■■ Configure 802.1Q VLAN. Add the three member ports and the router port to the same VLAN. ■■ Enable IGMP Snooping. User Guide 30 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 35
Switching Configuration Examples Demonstrated with TL-SG1016PE, the following section provides configuration steps. 5.1.3 Configuration Steps 1) Choose the menu VLAN > 802.1Q 3 as untagged ports. Select port 4 as a tagged port. Click Add/Modify. Figure 5-2 Configuring 802.1Q VLAN User Guide 31 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 36
bundle multiple physical ports into one logical interface. In this case, we bundle port 1, port 2 and port 3 of both switches into one logical interface. User Guide 32 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 37
1 Hosts Port 2 Switch A Port 3 Port 2 Port 3 Switch B Servers Demonstrated with TL-SG1016PE, the following section provides configuration steps. The configuration steps are similar for both switches, Add Port 1, Port 2 and Port 3 to LAG 1. Click Apply. Figure 5-6 Configuring LAG User Guide 33 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 38
Enable Disable Default settings of LAG are listed in the following table. Table 6-3 Default Settings of LAG Configuration Parameter Group ID Default Setting LAG 1 User Guide 34 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 39
Part 4 Monitoring CHAPTERS 1. Monitoring 2. Viewing Port Statistics 3. Configuring Port Mirror 4. Testing Cables 5. Configuring Loop Prevention 6. Appendix: Default Parameters - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 40
the traffic on the switch. 1.2 Supported Features Port Statistics Port Statistics is used to analyze the mirrored packets for monitoring and troubleshooting the network. Cable Test This switch provides distance to the problem location, which facilitates you to locate and diagnose the trouble spot of - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 41
the port number of the switch. Status Displays whether the port is enabled or disabled. Link Status Displays the link state of the port. TxGoodPkt Displays the number of packets transmitted on the port. Error RxBadPkt Displays the number of error packets received on the port. User Guide 37 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 42
: ●● The frames with more than 1518 bytes, less than 64 bytes or with bad FCS (Frame Check Sequence) are recorded as BadPkts. ●● Because of the supporting feature of jumbo frame, the frames with more than 1518 bytes and less than 10000 bytes will be recorded as GoodPkts and BadPkts at the - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 43
configure port mirror: 1) Enable the port mirror feature globally. Specify a mirroring port. Click Apply. Port Mirror Enable or disable the port mirror feature globally. User Guide 39 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 44
below, you can verify the configuration result for port mirroring. Note: The LAG member ports cannot be set as a mirroring port or mirrored port. User Guide 40 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 45
: No device is connected to the other end or the connection is broken. Crosstalk: Impedance mismatch due to the poor quality of the cable. User Guide 41 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 46
Monitoring Testing Cables Cable Fault Distance (m) If the connection status is Normal, here displays the length of the cable. If the connection status is Close (or Short), Open, or Crosstalk, here displays the length from the port to the trouble spot. User Guide 42 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 47
Follow these steps to configure loop prevention: 1) Enable or disable loop prevention. Loop Prevention Enable or disable the loop prevention feature globally. 2) Click Apply. User Guide 43 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 48
Default settings of Loop Prevention are listed in the following table. Table 6-2 Default Settings of Loop Preventikon Configuration Parameter Loop Prevention Default Setting Enable User Guide 44 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 49
Part 5 Configuring VLAN CHAPTERS 1. Overview 2. Configuring MTU VLAN 3. Configuring Port Based VLAN 4. Configuring 802.1Q VLAN 5. Configuration Example for 802.1Q VLAN 6. Appendix: Default Parameters - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 50
management of devices in the same work group but located in different places. There are 3 types of VLAN modes supported on the switch: ■■ MTU VLAN MTU VLAN (Multi-Tenant Unit VLAN) defines an uplink port which will build VLAN the frame belongs to. On receiving an untagged frame, the User Guide 46 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 51
. When a specific VLAN mode is enabled, the other two VLAN modes will be disabled automatically and the corresponding VLAN configuration will be lost. ●● The switch supports up to 32 VLANs simultaneously. User Guide 47 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 52
Select the desired uplink port from the drop-down list. The uplink port will build up several VLANs with each of the other ports. User Guide 48 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 53
a port is removed from all the other VLANs, it is added to VLAN 1 automatically. ●● VLAN 1 includes at least one port and cannot be deleted. User Guide 49 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 54
VLAN. 2) Configure the PVID. 4.1 Configuring the VLAN Choose the menu VLAN > 802.1Q VLAN to load the following page. Figure 4-1 Configuring 802.1Q VLAN User Guide 50 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 55
a member of the other VLANs. ●● Once a port is removed from all the current VLANs, it is added to VLAN 1 automatically. ●● VLAN 1 cannot be deleted. User Guide 51 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 56
: ●● The PVID configuration will take effect only when 802.1Q VLAN mode is enabled. ●● You can specify a PVID only when the corresponding VLAN exists. User Guide 52 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 57
VLAN on both switches. ■■ Create VLAN 2. On Switch A, add port 2 and port 4 to VLAN 2, while on Switch B, add port 1, port 2 and port 4 to VLAN 2. User Guide 53 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 58
a port is connected to terminal devices like computers, add the port to the corresponding VLANs as an untagged port, because terminal devices typically do not support VLAN tags. User Guide 54 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 59
Configuring VLAN Configuration Example for 802.1Q VLAN 5.3 Configuration Steps Demonstrated with TL-SG1016PE, the following section provides configuration steps. The configuration steps on both switches are configuration as Enable. Click Apply. Figure 5-2 Configuring 802.1Q VLAN User Guide 55 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 60
an untagged port, and add port 4 to the VLAN as a tagged port. Click Add/Modify. Figure 5-3 Creating VLAN 2 and Adding Ports to the VLAN User Guide 56 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 61
Setting to load the following page. Specify the PVID of port 2 as 2 and click Apply. Specify the PVID of port 3 as 3 and click Apply. User Guide 57 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 62
Configuring VLAN Figure 5-5 Configuring 802.1Q PVID Configuration Example for 802.1Q VLAN User Guide 58 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 63
.1Q VLAN Configuration Parameter 802.1Q VLAN Configuration Default Setting Disable Table 6-4 Default Settings of 802.1Q VLAN PVID Configuration Parameter PVID Default Setting 1 User Guide 59 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 64
Part 6 Configuring QoS CHAPTERS 1. QoS 2. Configuring Basic QoS 3. Configuring Bandwidth Control 4. Configuring Storm Control 5. Configuration Example for Basic QoS 6. Appendix: Default Parameters - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 65
. With QoS (Quality of Service) technology, you can classify and prioritize network traffic to provide differentiated services for certain types of traffic. 1.2 Supported Features With the QoS feature, the packets will be automatically discarded to avoid network broadcast storm. User Guide 61 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 66
802.1P Based and DSCP Based. ■■ Port Based The port based QoS mode supports four priority queues, which are labeled as 1 (Lowest), 2 (Normal), DSCP priority determines the priority of packets based on the ToS (Type of Service) field in their IP header. RFC2474 re-defines the ToS field in the Guide 62 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 67
that the packets from the port are mapped to. The priorities are labeled as 1, 2, 3 and 4. Among them, the bigger value means the higher priority. User Guide 63 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 68
but without IP header base on the PRI field. Finally, the switch prioritizes packets without VLAN tag or IP header based on port priority. User Guide 64 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 69
for sending packets on the port. If the rate for sending packets on the port exceeds the egress rate, the packets will be discarded. User Guide 65 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 70
to ensure the switch works normally. ●● For ports in the same LAG, bandwidth control should be configured the same to ensure a successful port aggregation. User Guide 66 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 71
the packets on the port. If the rate for receiving the packets on the port exceeds the total rate, the packets will be discarded. User Guide 67 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 72
be disabled for that port automatically. ●● For ports in the same LAG, storm control should be configured the same to ensure a successful port aggregation. User Guide 68 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 73
department. Follow these procedures to configure QoS in port based mode. 1) Enable port based mode. 2) Map port 1 and port 2 to different priorities queues. Demonstrated with TL-SG1016PE, the following section provides configuration steps. User - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 74
Setting section, specify the priority queue for port 1 as 1(Lowest) and click Apply. Specify the priority queue for port 2 as 4(Highest) and click Apply. User Guide 70 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 75
Figure 5-3 Setting Different Priorities for Port 1 and Port 2 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 76
6 Appendix: Default Parameters Default settings of QoS basic configuration are listed in the following table. Table 6-1 Default Settings of QoS Basic Configuration Parameter QoS Mode Priority Queue Default Setting DSCP/802.1P Based 1 (Lowest) Default settings of Bandwidth Control configuration - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 77
Part 7 Configuring PoE (Only for Certain Devices) CHAPTERS 1. Overview 2. Configuring PoE 3. Configuring PoE Auto Recovery 4. Configuring Extend Mode 5. Appendix: Default Parameters - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 78
1 Overview Note: The PoE feature is only available on certain devices. To check whether your device supports this feature, refer to the datasheet. PoE (Power over Ethernet) is a remote power supply function non-standard PDs. Only standard PDs can be powered via TP-Link PoE switches. User Guide 74 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 79
PoE 2 Configuring PoE Note: PoE configuration is only available on certain devices. To check whether your device supports this feature, refer to the actual web interface. Choose the menu PoE > PoE config to load the Displays the real-time system remaining power of the PoE switch. User Guide 75 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 80
: You can enter a value manually. Power (w) Displays the real-time power supply of the port. Current (mA) Displays the real-time current of the port. Voltage (v) Displays the real-time voltage of the port. PD Class Displays the class which the linked PD belongs to. Power Status Displays - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 81
on certain devices. To check whether your device supports this feature, refer to the actual web interface. With PoE Auto Recovery enabled, the switch detects the link status between the ports and connected PDs. The Apply. PoE Auto Recovery Enable or disable PoE Auto Recovery globally. User Guide 77 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 82
Enable or disable PoE Auto Recovery on the desired ports. To make it enabled, enable PoE Auto Recovery both globally and on the port. User Guide 78 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 83
Configuring Extend Mode Note: Extend Mode is only available on certain devices. To check whether your device supports this feature, refer to the actual web interface. With Extend Mode enabled on the port, the maximum or Disable from the drop down list of Extend Mode. Then click Apply. User Guide 79 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 84
Disabled Default settings of Extend Mode are listed in the following table. Table 5-3 Default Settings of Extend Mode Parameter Extend Mode Default Setting Disabled User Guide 80 - TP-Link TL-SG1428PE | Easy Smart SwitchUN User Guide - Page 85
COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-Link Corporation Limited. Other brands and product names are trademarks or registered trademarks of their respective holders. No part of the specifications may be reproduced in
User Guide