Thermador PH42GS Design Guide - Ventilation

Thermador PH42GS Manual

Thermador PH42GS manual content summary:

  • Thermador PH42GS | Design Guide - Ventilation - Page 1
    MODELS SHOWN: HPIN48HS ISLAND HOOD, PRD486GDHU PRO HARMONY® RANGE 128 AND T24IW800SP FREEDOM® WINE PRESERVATION COLUMN
  • Thermador PH42GS | Design Guide - Ventilation - Page 2
    systems remove smoke, grease and unhealthy airborne contaminants. From standard wall to specialty hoods, downdrafts, island and custom inserts, each model has one thing in common: legendary Thermador performance. These powerful, quiet systems tackle unwanted smoke, grease, heat and odors - quietly
  • Thermador PH42GS | Design Guide - Ventilation - Page 3
    18-INCH TALL WALL HOODS 42" PH42GS 48" PH48GS 54" PH54GS 24-INCH DEPTH, 18-INCH TALL WALL HOODS 24-INCH DEPTH, 11-INCH TALL WALL HOODS 30" PH30HS 36" PH36HS or exceed it by 3 inches on either side. Install these hoods only with Thermador Blowers. *High heat tested to accommodate Pro Harmony® or
  • Thermador PH42GS | Design Guide - Ventilation - Page 4
    VENTILATION 30-INCH PRO HARMONY 36-INCH PRO HARMONY 24-INCH DEPTH 48-INCH PRO HARMONY 30-INCH RANGETOP 36-INCH RANGETOP 24-INCH DEPTH 48-INCH RANGETOP 1.800.735.4328 | THERMADOR.COM 131
  • Thermador PH42GS | Design Guide - Ventilation - Page 5
    30" UCVM30FS 132 DOWNDRAFTS 36" UCVM36FS For optimal performance, the width of the hood should equal that of the cooktop or rangetop or exceed it by 3 inches on either side. Install these hoods only with Thermador Blowers. *Compatible with cooktops of widths up to 42" †Also compatible with Pro
  • Thermador PH42GS | Design Guide - Ventilation - Page 6
    VENTILATION 30-INCH ELECTRIC COOKTOP 30-INCH SENSOR ELECTRIC COOKTOP 36-INCH ELECTRIC COOKTOP 36-INCH SENSOR ELECTRIC COOKTOP 1.800.735.4328 | THERMADOR.COM 133
  • Thermador PH42GS | Design Guide - Ventilation - Page 7
    Information BLOWER selection and duct guide PROFESSIONAL SERIES Blower CFM Type WALL HOODS ISLAND HOODS CUSTOM INSERTS Model No. Available Sizes (Widths) PH_GS 36" / 42" / most hardware stores, unless otherwise indicated with a Thermador model number. Remote Inline Integrated Type Model No
  • Thermador PH42GS | Design Guide - Ventilation - Page 8
    RFPLT600 RFPLT1000 6-Inch 8-Inch 10-Inch Hood Information Included Required* 6-Inch 8-Inch 10-Inch Vertical Horizontal Side & • • • • • • • • • • • • • • • • • • • • • 1.800.735.4328 | THERMADOR.COM Transition with Backdraft Damper Duct Size at Discharge Discharge Direction
  • Thermador PH42GS | Design Guide - Ventilation - Page 9
    BLOWER options AND PRESSURE CURVES Integrated (MOUNTED ON HOOD) VTN600CV2C - 600 CFM VTN600F - 600 CFM VTN630C - 600 CFM VTN1080F - 1000 CFM VTN1000F - 1000 CFM VTN1030C - 1000 CFM 136
  • Thermador PH42GS | Design Guide - Ventilation - Page 10
    NOTE: All measurements are made with 3 ft. straight duct, 90° bend followed by 1 ft. straight duct. These are NOT free blowing measurements. 1.800.735.4328 | THERMADOR.COM 137
  • Thermador PH42GS | Design Guide - Ventilation - Page 11
    2 7 2 8 2 2' Long 3 1/4" x 10" N/A 20 Flex 3 1/4" x 10" to Round 10 1 7" Inline Backdraft 7 Damper 3 1/4" x 10" Roof Jack N/A and Shutter NOTE: These commonly used installation parts can be purchased at a local hardware store. Thermador does not manufacture all these parts. 138
  • Thermador PH42GS | Design Guide - Ventilation - Page 12
    with glass designs available • Halogen lighting • Dishwasher-safe, stainless steel frame filters • Automatic Clean Filter Reminder light ISLAND hoods Thermador Island Hoods offer excellent overall efficiency in drawing away smoke, moisture and heat. • An option for when a wall surface is not
  • Thermador PH42GS | Design Guide - Ventilation - Page 13
    MODELS SHOWN: PH48HS WALL HOOD AND PRG486GDH PRO HARMONY® RANGE AND PA12CVRJ GRIDDLE 140 COVER ACCESSORY
  • Thermador PH42GS | Design Guide - Ventilation - Page 14
    VENTILATION - WALL HOODS VENTILATION WALL HOODS Thermador Wall Hoods put the finishing touch on your cooking system, with deep capture areas for the best overall efficiency in drawing away smoke, moisture and heat. These elegant hoods combine style with vigorous performance, generating ventilation
  • Thermador PH42GS | Design Guide - Ventilation - Page 15
    temperature on our optional Keep-Hot Shelf. (Perfect for PH36GS, PH42GS, PH48GS and PH54GS) PLANNING INFORMATION MODEL OPTIONS When selecting a ventilation guide. ELECTRICAL SPECIFICATIONS Be sure your Thermador Wall Hood is properly installed and grounded by a qualified technician. Installation,
  • Thermador PH42GS | Design Guide - Ventilation - Page 16
    information in this design guide provides key features, product dimensions, cutouts and installation specifications. Before installing a Thermador Wall Hood, be sure to verify the cutout dimensions and electrical connections. Also, always consult with the installation manual packed with the product
  • Thermador PH42GS | Design Guide - Ventilation - Page 17
    VENTILATION 27-inch DEPTH WALL HOOD (36"/42"/48"/54") PH36GS / PH42GS / PH48GS / PH54GS PROFESSIONAL PH36GS - 36-Inch PH42GS - 42-Inch PH48GS - 48-Inch PH54GS - 54-Inch SPECIFICATIONS Available Hood Widths UL Approved for Damp Environments Blower Duct Size at Discharge Ducting Direction Dishwasher
  • Thermador PH42GS | Design Guide - Ventilation - Page 18
    (36"/42"/48"/54") PH36GS / PH42GS / PH48GS / PH54GS INSTALLATION OPTIONS Thermador Wall Hoods may be installed above a Thermador Cooktop or Range to create a convenient cooking center. Refer to the appropriate section for additional specifications. Hood installation height above a cooktop or range
  • Thermador PH42GS | Design Guide - Ventilation - Page 19
    - 30-Inch PH36HS - 36-Inch PH48HS - 48-Inch SPECIFICATIONS Available Hood Widths CSA Approved for Damp Environments Blower Duct Size at Discharge Ducting Direction and two shelves. Duct Cover Stainless steel duct cover for wall hood applications Width 30-Inch 36-Inch 48-Inch 6-Inch High DC30US
  • Thermador PH42GS | Design Guide - Ventilation - Page 20
    to the appropriate section for additional specifications. Hood installation height above a cooktop or range can vary. To obtain the necessary installation height above a Thermador Professional Cooktop or Range, consult the appliance's installation manual. Accessory 6" and/or 12" duct covers are
  • Thermador PH42GS | Design Guide - Ventilation - Page 21
    12-Inch High DCT30US DCT36US DCT48US Recirculation Kit for 30" Hood Only RECIRC30FS 30" wide Stainless Steel Backsplash PA30JBS 30" wide PA36JBS 36" wide PA48JBS 48" wide 148 - Stainless steel finish - Perfect for hard to duct installations - Use with 600 CFM blowers only Replacement Charcoal
  • Thermador PH42GS | Design Guide - Ventilation - Page 22
    installation manual. Accessory 6" and/or 12" duct covers are used to fill the space between the hood and ceiling. This Thermador Wall Hood can be mounted on a wall or suspended from a cabinet. The cabinet must be structurally joined to the wall studs to support the weight of this hood. These hoods
  • Thermador PH42GS | Design Guide - Ventilation - Page 23
    best recipes ACCESSORIES Duct Cover Stainless steel duct cover for wall hood applications Width 30-Inch 36-Inch 48-Inch 6-Inch High 150 - Stainless steel finish - Perfect for hard to duct installations - Use with 600 CFM blowers only Replacement Charcoal Filters CHFILT3036 For use
  • Thermador PH42GS | Design Guide - Ventilation - Page 24
    installation manual. Accessory 6" and/or 12" duct covers are used to fill the space between the hood and ceiling. This Thermador Wall Hood can be mounted on a wall or suspended from a cabinet. The cabinet must be structurally joined to the wall studs to support the weight of this hood. These hoods
  • Thermador PH42GS | Design Guide - Ventilation - Page 25
    your best recipes ACCESSORIES Duct Cover Stainless steel duct cover for wall hood applications Width 30-Inch 36-Inch 48-Inch 6-Inch High DC30US 152 - Stainless steel finish - Perfect for hard to duct installations - Use with 600 CFM blowers only Replacement Charcoal Filters CHFILT3036 For
  • Thermador PH42GS | Design Guide - Ventilation - Page 26
    installation manual. Accessory 6" and/or 12" duct covers are used to fill the space between the hood and ceiling. This Thermador Wall Hood can be mounted on a wall or suspended from a cabinet. The cabinet must be structurally joined to the wall studs to support the weight of this hood. These hoods
  • Thermador PH42GS | Design Guide - Ventilation - Page 27
    MODELS SHOWN: HDDW36FS CHIMNEY WALL DRAWER HOOD, SGSX365FS GAS COOKTOP AND 154 MED301JS BUILT-IN OVEN
  • Thermador PH42GS | Design Guide - Ventilation - Page 28
    VENTILATION - CHIMNEY WALL HOODS VENTILATION CHIMNEY WALL HOODS Our Masterpiece® Series chimney style wall hoods impart a more traditional feel to the kitchen space and create a dramatic brilliantly illuminates your cooking space for excellent visibility. 1.800.735.4328 | THERMADOR.COM 155
  • Thermador PH42GS | Design Guide - Ventilation - Page 29
    information in this design guide provides key features, product dimensions, cutouts and installation specifications. Before installing a Thermador Chimney Wall Hood, be sure to verify the cutout dimensions and electrical connections. Also, always consult with the installation manual packed with the
  • Thermador PH42GS | Design Guide - Ventilation - Page 30
    ") to over 10' (or 120"). Before selecting your hood, check your available installation space and any extra space that may remain after proper installation of your hood and cooktop or range. This extra space can be filled using Thermador's Stainless Steel Duct Cover or Chimney Extension Accessories
  • Thermador PH42GS | Design Guide - Ventilation - Page 31
    - 8" Round duct size - Telescopic chimney - adjustable at installation - Blowers sold separately - Choose from Inline, Remote or Integrated controls - Halogen lighting spotlights your best recipes SPECIFICATIONS Available Hood Widths Blower Duct Size at Discharge Ducting Direction Ceiling Heights
  • Thermador PH42GS | Design Guide - Ventilation - Page 32
    non-professional gas, electric, or induction cooktop, consult the appliance's installation manual. Thermador Chimney Wall Hoods must be mounted on a wall. These hoods are designed to be used for vertical discharge. The HMCN_FS hood offers the flexibility to choose a blower from our lineup to fit
  • Thermador PH42GS | Design Guide - Ventilation - Page 33
    Vertical ducting direction - Telescopic chimney - adjustable at installation - Hood includes filters, lights, backdraft damper and transition Design buttons - Halogen lighting spotlights your best recipes SPECIFICATIONS Available Hood Widths Blower Duct Size at Discharge Ducting Direction Ceiling
  • Thermador PH42GS | Design Guide - Ventilation - Page 34
    above a cooktop can vary. To obtain the necessary installation height above a Thermador nonprofessional gas, electric, or induction cooktop, consult the appliance's installation manual. Thermador Chimney Wall Hoods must be mounted on a wall. These hoods are designed to be used for vertical discharge
  • Thermador PH42GS | Design Guide - Ventilation - Page 35
    - adjustable at installation - Hood includes filters, backdraft damper and transition Design - Brushed stainless steel finish - Welded, polished seams for a flawless design - Premium electronic touch controls - Halogen lighting spotlights your best recipes THERMADOR EXCLUSIVE ACCESSORIES Chimney
  • Thermador PH42GS | Design Guide - Ventilation - Page 36
    above a cooktop can vary. To obtain the necessary installation height above a Thermador nonprofessional gas, electric, or induction cooktop, consult the appliance's installation manual. Thermador Chimney Wall Hoods must be mounted on a wall. These hoods are designed to be used for vertical discharge
  • Thermador PH42GS | Design Guide - Ventilation - Page 37
    164 MODELS SHOWN: HMIB40HS ISLAND HOOD AND CIT365KB INDUCTION COOKTOP
  • Thermador PH42GS | Design Guide - Ventilation - Page 38
    VENTILATION - ISLAND HOODS VENTILATION ISLAND HOODS Thermador Island Hoods put the finishing touches on your cooking system, with excellent overall efficiency in drawing away smoke, moisture and heat. The adjustable chimney height is perfect over island cooktop or range installations. Dishwasher-
  • Thermador PH42GS | Design Guide - Ventilation - Page 39
    The information in this design guide provides key features, product dimensions and installation specifications. Before installing a Thermador Island Hood, be sure to verify the dimensions and electrical connections. Also, always consult with the installation manual packed with the product for
  • Thermador PH42GS | Design Guide - Ventilation - Page 40
    several inches. Kitchen ceiling heights can vary between 7'6" (or 90") to over 10' (or 120"). Before selecting a Thermador Hood, check the available installation space and any extra space that may remain after proper installation of a hood and cooktop or range. This extra space can be filled using
  • Thermador PH42GS | Design Guide - Ventilation - Page 41
    into any kitchen - Halogen lighting spotlights your best recipes - Brushed stainless steel finish - Stainless steel control buttons SPECIFICATIONS Available Hood Widths Blower Duct Size at Discharge Ducting Direction Ceiling Heights Dishwasher-safe Filters Halogen Lighting 12 Volt, 20 Watt Max
  • Thermador PH42GS | Design Guide - Ventilation - Page 42
    height above a cooktop can vary. To obtain the necessary installation height above a Thermador Cooktop or Range, consult the appliance's installation manual. Thermador Island Hoods are suspended from the ceiling. These hoods are designed to be used for vertical discharge. A blower must be
  • Thermador PH42GS | Design Guide - Ventilation - Page 43
    kitchen - Halogen lighting spotlights your best recipes - Stainless steel control buttons ACCESSORIES Island Hood Recirculation Kit RECIRISL - Stainless steel finish - Perfect for hard to duct installations - Use with 600 CFM blowers only 170 Replacement Charcoal Filters CHFILISL For use with
  • Thermador PH42GS | Design Guide - Ventilation - Page 44
    height above a cooktop can vary. To obtain the necessary installation height above a Thermador Cooktop or Range, consult the appliance's installation manual. Thermador Island Hoods are suspended from the ceiling. These hoods are designed to be used for vertical discharge. A 600 CFM blower
  • Thermador PH42GS | Design Guide - Ventilation - Page 45
    your best recipes - Brushed stainless steel finish - Premium electronic touch controls ACCESSORIES Island Hood Recirculation Kit RECIRISL - Stainless steel finish - Perfect for hard to duct installations - Use with 600 CFM blowers only 172 Replacement Charcoal Filters CHFILISL For use with
  • Thermador PH42GS | Design Guide - Ventilation - Page 46
    height above a cooktop can vary. To obtain the necessary installation height above a Thermador Cooktop or Range, consult the appliance's installation manual. Thermador Island Hoods are suspended from the ceiling. These hoods are designed to be used for vertical discharge. A 600 CFM blower
  • Thermador PH42GS | Design Guide - Ventilation - Page 47
    174 MODELS SHOWN: VCI248DS PROFESSIONAL SERIES CUSTOM INSERT
  • Thermador PH42GS | Design Guide - Ventilation - Page 48
    VENTILATION - CUSTOM INSERTS VENTILATION CUSTOM INSERTS Use Thermador Custom Hood Inserts within custom hood applications to create a seamless design with wall or island applications. These inserts efficiently and quietly remove odor and steam with easy-to-access controls. Inserts
  • Thermador PH42GS | Design Guide - Ventilation - Page 49
    36-inch and 48-inch widths. The Masterpiece® Series Custom Hood Inserts are available in 21-inch (for 30-inch wide installations) and 29-inch (for 36-inch wide installations). ELECTRICAL SPECIFICATIONS Be sure your Thermador Custom Insert is properly installed and grounded by a qualified technician
  • Thermador PH42GS | Design Guide - Ventilation - Page 50
    The information in this design guide provides key features, product dimensions and installation specifications. Before installing a Thermador Custom Hood Insert, be sure to verify the dimensions and electrical connections. Also, always consult with the installation manual packed with the product for
  • Thermador PH42GS | Design Guide - Ventilation - Page 51
    Liners LINER236 36" wide LINER248 48" wide LINER254 54" wide - Stainless steel custom hood liners to protect the exterior base of custom insert - Custom hood liner completes custom insert installation 178 Remote Control Panel VCI2REMKS - S tainless steel finish - C able-connected to blower and
  • Thermador PH42GS | Design Guide - Ventilation - Page 52
    30" to 36" and can vary from product to product and by manufacturer. Refer to the installation manual of the rangetop or range prior to the design and installation of the custom hood insert. These hoods are designed to be used for vertical discharge. A blower must be purchased separately. BLOWER
  • Thermador PH42GS | Design Guide - Ventilation - Page 53
    Liners LINER236 36" wide LINER248 48" wide LINER254 54" wide - Stainless steel custom hood liners to protect the exterior base of custom insert - Custom hood liner completes custom insert installation 180 Remote Control Panel VCI2REMKS - S tainless steel finish - C able-connected to blower and
  • Thermador PH42GS | Design Guide - Ventilation - Page 54
    48"/54") VCIB36JP / VCIB48JP / VCIB54JP INSTALLATION OPTIONS Thermador Custom Hood Inserts within custom hood applications create a seamless design with wall or island applications. Thermador Professional Series Custom Hood Inserts may be installed above a Thermador Professional Cooktop or Range to
  • Thermador PH42GS | Design Guide - Ventilation - Page 55
    to protect the exterior base of custom insert - Custom hood liner completes custom insert installation Remote Control Panel VCI2REMFS - S tainless steel finish - C able-connected to blower and hood controls - C able length 30 ft. Baffle Filters BAFFLT30 30" wide BAFFLT36 36" wide BAFFLT48
  • Thermador PH42GS | Design Guide - Ventilation - Page 56
    to the installation manual of the rangetop or range prior to the design and installation of the custom hood insert. These hoods are designed to pages 134-135 for further details. *Please visit thermador.com for tips & hints on installation of VTI1010D as an integrated solution REMOTE (Mounted to
  • Thermador PH42GS | Design Guide - Ventilation - Page 57
    184 MODELS SHOWN: UCVM36FS 36-INCH DOWNDRAFT WITH CIT365KM INDUCTION COOKTOP
  • Thermador PH42GS | Design Guide - Ventilation - Page 58
    VENTILATION - DOWNDRAFT VENTILATION DOWNDRAFT If you prefer a concealed look, choose a Thermador Downdraft Ventilation Unit, which offers space efficiency when a hood is not preferred. The full-face filter combines a filter with a splatter shield in one easy-to-remove, dishwasher-safe element.
  • Thermador PH42GS | Design Guide - Ventilation - Page 59
    in this design guide provides key features, product dimensions, cutouts and installation specifications. Before installing a Thermador Downdraft Hood, be sure to verify the cutout dimensions and electrical connections. Also, always consult with the installation manual packed with the product
  • Thermador PH42GS | Design Guide - Ventilation - Page 60
    important factor in determining CFM needs for a hood. Professional Gas Rangetops generally should have 1 CFM proper ducting. Use a qualified and trained installer. Local building codes may require the your area. If using a 10" duct, Thermador recommends not exceeding 150 feet of duct. Transitions
  • Thermador PH42GS | Design Guide - Ventilation - Page 61
    UCVM36FS - 36-Inch SPECIFICATIONS Available Hood Widths Blower Duct Size at Discharge only with Thermador Downdraft and Integrated Blower - Replacement filters are ordered as a service item - 15 1/8" CV2T10 Improves overall performance when installing with Thermador's 1,000 CFM Inline or Remote
  • Thermador PH42GS | Design Guide - Ventilation - Page 62
    VENTILATION - DOWNDRAFT INSTALLATION OPTIONS The Thermador Downdraft Hood System is available in 30-inch or 36-inch widths. It is intended for installation with Thermador non-professional gas, electric or induction cooktops only. A Recirculation Kit (RECIRC36DF) can be purchased separately and used
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

MODELS SHOWN: HPIN48HS ISLAND HOOD, PRD486GDHU PRO HARMONY
®
RANGE
AND T24IW800SP FREEDOM
®
WINE PRESERVATION COLUMN
128