Tripp Lite 5P750R Eaton 5P UPS Installation and User Manual
Tripp Lite 5P750R Manual
View all Tripp Lite 5P750R manuals
Add to My Manuals
Save this manual to your list of manuals |
Tripp Lite 5P750R manual content summary:
- Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 1
Copyright © 2012 EATON All rights reserved. Service and support: Call your local service representative 620-00082-01-us (en) Installation and user manual Tower models 5P 750 5P 1000 5P 1500 5P 850G 5P 1550G 1U Rack models 5P 550 R 5P 750 R 5P 1000 R 5P 1500 R 5P 850G R 5P 1550G R ENGLISH - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 2
Page 2 620-00082-01-us (en) - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 3
ENGLISH IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. The 5P models that are covered in this manual are intended for installation in an environment within 0 to - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 4
below must be observed: - servicing of batteries should be performed or supervised by personnel knowledgeable about betteries and the required precautions. - when replacing batteries, replace with the same type and number of batteries or battery packs. - do not dispose of batteries in a fire. The - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 5
20 4.2 Starting the UPS on Battery 20 4.3 UPS Shutdown...20 4.4 Operation on Battery Power 20 4.5 Return of AC Input Power 21 4.6 UPS remote control functions 21 5. Maintenance 22 5.1 Troubleshooting...22 5.2 Battery-module replacement 23 6. Appendices 25 6.1 Technical specifications - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 6
, please read the booklet presenting the safety instructions. Then follow the instructions in this manual. To discover the entire range of EATON service life, the product must be transported to a processing center for electrical and electronic waste. Battery The product contains lead-acid batteries - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 7
ENGLISH 2.1 Standard installations Tower models D H Description 5P 750 5P 1000 5P 1500 5P 850G 5P 1550G W Weights (lb/kg) 22.7 / 10.3 24.4 / 11.05 35.3 / 16.01 21.9 / 9.9 35.2 / 15.9 Dimensions (inch/mm) D x W x H 13.6 x 5.9 x 9.1 / 345 x 150 x 233 13.6 x 5.9 x 9.1 / 345 x 150 x 233 17.5 x 5.9 - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 8
2. Presentation 2.2 Tower rear panels 5P 750 / 5P 1000 6a 5 3 2 6b 1 8 4 7 9 5P 1500 6a 5 3 2 6b 1 4 9 7 8 5P 850G 6a 5 3 2 6b 1 7 4 8 5P 1550G 6a 5 3 2 6b 1 4 8 7 Page 8 (1) USB communication port (2) RS232 communication port (3) Slot for optional - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 9
ENGLISH 2.3 Rack rear panels 5P 550 R / 5P 750 R / 5P 1000 R 8 7 2149 5 6a 6b 3 5P 1500 R 387 2149 5 6a 6b 2. Presentation (1) USB communication port (2) RS232 communication port (3) Slot for optional communication card (4) Connector for ROO (remote ON/OFF) or RPO (Remote Power OFF) - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 10
table shows the indicator status and description: Indicator Status Description On Green The UPS is operating normally. On Yellow On Red The UPS is on battery mode. The UPS has an active alarm or fault. See troubleshooting on page 18 for additional information. Page 10 620-00082-01-us (en) - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 11
provided by the UPS Note: If other indicator appears, see troubleshooting on page 18 for additional information. Operation status Standby mode UPS is powering and protecting the equipment. In AVR mode No beep On Battery Battery LED is on 1 beep every 10 seconds End of backup time 1 beep every - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 12
overrule user settings for load segments. Start battery test Starts a manual battery test Reset fault state Clears active faults settings are in all supported languages. Modify LCD screen brightness and contrast to adapt to room light conditions. [Enabled] [Disabled on battery] [Always disabled] - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 13
to equipment connected to Group 1 and/or Group 2 outlets. This feature allows the shedding of non-critical loads in order to conserve battery power for critical loads connected to the Primary group. [10 %] [15 %] [20 %] ... [100 %] [105 %] [105 %] Sets critical percentage of load where alarm - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 14
3. Installation 3.1 Unpacking and contents check Tower models 1 8 4 2 3 5 Rack models 9 1 2 6 3 7 8 4 5 (1) 5P UPS (2) Quick start and safety instructions (3) User manual and IPSS (Intelligent Power Software Suite) CD-ROM (4) RS232 communication cable (5) USB communication cable (6) 1U Rack - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 15
. This is normal and does not damage the UPS or present any safety concern. A - C onnect the battery module (never pull on the wires). A B B - A ttach the left-hand side of the front panel by sliding it then by locking the push button. C - A ttach - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 16
3. Installation 3.4 Installation of tower models 3.5 Installation of rack model for 2 post (option) Follow steps 1 to 5 for 2 post mounting. 1 1 2 2 3 3 5 4 5 Use optional 1U 2 post rail kit. Page 16 620-00082-01-us (en) - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 17
ENGLISH 3.6 Installation of rack models (550 R) Follow steps 1 to 3 for rack mounting. 1 2 3 3. Installation 2 3 3.7 Installation of rack models Follow steps 1 to 4 for module mounting on the rails. 1 1 2 3 2 3 4 4 The rails and necessary hardware are supplied by EATON. 620-00082-01-us ( - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 18
3. Installation 3.8 Installation of rack model for wall mounting 1 2 1 1 2 2 Page 18 620-00082-01-us (en) - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 19
Characteristics of the optocouplers communication port (optional) • Pins 1, 3, 4, 5, 6, 10: not used • Pin 2: common (user) • Pin 7: low battery • Pin 8: operation on battery power • Pin 9: UPS ON, equipment supplied n.o.: normally open contact When a signal is activated, the contact is closed - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 20
your equipment. 2. Check the UPS front panel display for active alarms or notices besides the "Battery mode" notice and notices that indicate missing utility power. Resolve any active alarms before continuing. See "Troubleshooting" on page 22. Check the UPS status from the front panel to view the - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 21
on the connected equipment because automatic UPS shutdown is imminent. End of battery backup time • LCD displays "End of backup time". • All to disconnect all the equipment connected to the UPS. Restarting the UPS requires manual intervention. • ROO: Remote ON/OFF allows remote action of button to - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 22
UPS continues to operate, but may shutdown if the load increases. The alarm resets when the condition becomes inactive. Contact your service representative for battery replacement. Event UPS fault An UPS event occurs Example: Remote Power OFF, the RPO contact has been activated to shutdown the UPS - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 23
wires). C C - R emove the plastique protection cover in front of the battery (one screw). D D - P ull the plastic tab to remove the battery block and replace it. Mounting the new battery module Carry out the above instructions in reverse order. • To ensure safety and high performance, use only - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 24
the wires). C D - R emove the metal protection cover in front of the battery (two screws). D E - P ull the plastic tab to remove the battery block and replace it. E Mounting the new battery module Carry out the above instructions in reverse order. • To ensure safety and high performance, use only - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 25
Power capacity @ 125 V Output Power @ 100 V AC Input power • Rated input voltage • Input voltage range • Input frequency range Output on battery power • Voltage • Frequency Battery (sealed lead acid, maintenance free) • Standard 5P 550 R 550 VA 420 W 550 VA 420 W 458 VA 350 W 5P 750 5P 750 - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 26
Power capacity @ 208 V Output Power @ 200 V AC Input power • Rated input voltage • Input voltage range • Input frequency range Output on battery power • Voltage • Frequency Battery (sealed lead acid, maintenance free) • Standard 5P 850G 5P 850G R 850 VA 600 W 765 VA 540 W 765 VA 540 W 5P 1550G - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 27
ENGLISH 6. Appendices 6.2 Glossary Backup time Time during which the load can be supplied by the UPS operating on battery power. Battery test Internal UPS test to check battery status. Cold start Deep discharge Load The devices connected to the UPS can be started even if AC input power is - Tripp Lite 5P750R | Eaton 5P UPS Installation and User Manual - Page 28
Page 28 620-00082-01-us (en)
ENGLISH
Tower models
5P 750
5P 1000
5P 1500
5P 850G
5P 1550G
Copyright © 2012
EATON
All rights reserved.
Service and support:
Call your local service representative
620-00082-01-us (en)
1U Rack models
5P 550 R
5P 750 R
5P 1000 R
5P 1500 R
5P 850G R
5P 1550G R
Installation
and user manual