ENGISH Installation and user manual 5P750RC 5P1000RC 5P1500RC Copyright © 2015 EATON All rights reserved. 5P 750VA -1.5 KVA EU_EN Page 1 - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 2
the risk of electric shock symbol. Important instructions that must always be followed. Do not discard the UPS or the UPS batteries in the trash. This product contains sealed lead acid batteries and must be disposed as it's explain in this manual. For more information, contact your local recycling - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 3
below must be observed: - servicing of batteries should be performed or supervised by personnel knowledgeable about batteries and the required precautions. - when replacing batteries, replace with the same type and number of batteries or battery packs. - do not dispose of batteries in a fire. The - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 4
operation 17 4.2 Starting the UPS on Battery 17 4.3 UPS Shutdown 17 4.4 Operation on Battery Power 17 4.5 Return of AC Input Power 18 4.6 UPS remote control functions 18 5. Maintenance 19 5.1 Troubleshooting 19 5.2 Battery-module replacement 20 6. Appendices 21 6.1 Technical specifications - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 5
, please read the booklet presenting the safety instructions. Then follow the indications in this manual. To discover the entire range of EATON service life, the product must be transported to a processing center for electrical and electronic waste. Battery The product contains lead-acid batteries - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 6
2. Presentation 2.1 Standard installations Rack model D H W Description 5P750RC 5P1000RC 5P1500RC Weights (kg/lb) 14.1/31.1 15.0/33.1 18.4/45.5 Dimensions (mm/inch) D xW x H 370*440*86.2 / 14.6*17.3*3.4 370*440*86.2 / 14.6*17.3*3.4 370*440*86.2 / 14.6*17.3*3.4 5P 750VA-1.5 KVA US_EN Page 6 - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 7
2.2 Rear panel 5P750RC & 5P1000RC & 5P1500RC ① ② ③ ④ ⑥ ⑦⑧ ⑤ 1) Attached 1.8 m input power cord for AC power source 2) Slot for optional communication card 3) Primary group : Outlets for connection of critical equipment 4) Group 1: programmable outlets for connection of equipment 5) Group 2: - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 8
shows the indicator status and description: Indicator Green Status Description On The UPS is operating normally Orange Red On The UPS is on Battery mode. On The UPS has an active alarm or fault. See trouble- shooting in section 5.1 for additional information. 5P 750VA-1.5 KVA US_EN Page 8 - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 9
provided by the UPS Note: If other indicator appears, see troubleshooting on section 5.1 for additional information. Operation status Standby mode Cause the equipment. In AVR mode 1 beep every 10 seconds On Battery The UPS is operating normally but the utility voltage is outside normal - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 10
Starts a manual battery test Clears battery configuration Displays the faults stored Clears faults UPS Type / Part Number / Serial Number / Firmware release / Com card supported languages. Modify LCD screen brightness and contrast to adapt to room light conditions . [Enabled] [Disabled on battery - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 11
is reached. [0 s] Every week(in constant charge, otherwise following ABM battery test method) 20 % 0% Battery charge mode [ABM cycling] [Constant charge] ABM cycling External battery [Auto detection] [Manual EBM set.] [Manual battery set.] Deep discharge protection [Yes] [No] If set to Yes - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 12
3. Installation 3.1 Unpacking and contents check ⑨ ⑩ ⑫ ⑬ ⑪ (9) 5P UPS (10) Rail and wall mounting kits (11) Quick start, safety instructions and environmental document (12) RS232 communication cable (13) USB communication cable Packing materials must be disposed of in compliance with all local - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 13
. . ○B ○A A. Remove the center panel B. Remove the left-hand side of the front panel C. Connect the battery module (never pull on the wires) ○C ○D D. Attach the left-hand side of the front panel by sliding it then by locking the push button E. Attach - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 14
3.3 Rack installation Follow steps 14 to 16 for model mounting on the rails. Use provided screws on step 15 of installation. Using a longer screw could present a safety risk. ⑭ ⑮ ⑮ ⑯ ⑯ ③ The rails and necessary hardware are supplied by EATON. 5P 750VA-1.5 KVA US_EN Page 14 - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 15
3.4 Wall mounting of rack model Use provided screws on step 17 of installation. Using a longer screw could present a safety risk. ⑰ ⑱ ⑱ ⑰ 5P 750VA-1.5 KVA US_EN Page 15 - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 16
the slot cover (2) secured by screws; 2. Insert the communication card in the slot 3. Secure the card cover with the 2 screws. • Pins 1, 3, 4, 5, 6, 10: not used • Pin 2: common (user) • Pin 7: low battery • Pin 8: operation on battery power • Pin 9: UPS ON, equipment supplied n.o.: normally open - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 17
. 2. Check the UPS front panel display for active alarms or notices besides the "Battery mode" notice and notices that indicate missing utility power. Resolve any active alarms before continuing. See "Troubleshooting" in section 5.1. Check the UPS status from the front panel to view the active - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 18
on the connected equipment because automatic UPS shutdown is imminent. End of battery backup time • LCD displays "End of backup time". • All to disconnect all the equipment connected to the UPS. Restarting the UPS requires manual intervention. • ROO: Remote ON/OFF allows remote action of button to - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 19
may shutdown if the load increases. The alarm resets when the condition becomes inactive. End of battery life The end of the battery life is reached. Contact your service representative for battery replacement. Event UPS fault An UPS event occurs Example: Remote Power OFF, the RPO contact has - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 20
by separating the two connectors ○C D. Remove the metal protection ○D cover in front of the battery (one screw) E. Remove the battery module and replace it ○E Mounting the new battery module Carry out the above instructions in reverse order. • To ensure safety and high performance, use only - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 21
to 151 V (1) 47 to 70 Hz (50 Hz system), 56.5 to 70 Hz (60 Hz system) (2) Output on battery power 120 V (-10/+6 %) (3) 50/60 Hz ±0.1 Hz 2 x 12 V 7.2 Ah 0 to 40 °C 2 x product is designed for IT power distribution system. 5P1500RC 1440 VA 1100 W 1080 VA 825 W 1440 VA 1100 W 3 x 12 - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 22
Programmable Outlets UPS UPS ON/OFF controlled by software Time during which the load can be supplied by the UPS operating on battery power. Internal UPS test to check battery status. The devices connected to the UPS can be started even if AC input power is not available. The UPS operates on - Tripp Lite 5P750RC | Eaton 5P750RC 5P1000RC and 5P1500RC UPS Installation and Us - Page 23
www.eaton.com/Powerquality 5P 7E50aVAto-1n.5 5KVPA US_EN Page 23