- Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 1
Eaton Tripp Lite SmartOnline Series Rack / Tower Advanced User's Guide SU5000RT SU6000RT BP180RT p/n: 614-40204 Revision 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 2
. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 3
TO OPERATOR'S MANUAL - Refer to your operator's manual for additional information, such as important operating and maintenance instructions. This symbol indicates To avoid accidents, observe the following directives: - Servicing of batteries should be performed or supervised by personnel - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 4
Product Safety • To connect the UPS, instructions and operation described in the manual must be followed in the indicated order. • CAUTION - To reduce the risk of fire, the unit connects only to a circuit provided with 20 or 30 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 5
of Operation ...27 6.1 Online Mode ...27 6.2 Battery Mode ...27 6.3 Low Battery Warning...27 6.4 Bypass Mode ...27 6.5 Standby Mode ...27 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 v - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 6
the Equipment ...29 7.3 Replacing the Batteries ...29 7.4 Recycling The Used Equipment ...31 8 Troubleshooting ...33 8.1 Typical Alarms and Faults ...33 8.2 Silencing the Alarm ...34 8.3 Service and Support ...35 9 Specifications ...37 9.1 Model Specifications ...37 vi Eaton Tripp Lite SmartOnline - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 7
utmost care. Please take the time to read the safety instructions and the advanced user guide to take full advantage of the many features of your of Life Eaton will process products at the end of their service life in compliance with local regulations. Eaton works with companies in charge of - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 8
all local regulations concerning waste. At the end of its service life, the product must be transported to a processing center it, and power quality can be erratic. These power problems have the potential to corrupt critical data, destroy unsaved work SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 9
Description Extended battery module 5K transformer module SmartOnline maintenance bypass module Two-post rail kit Network card Relay card Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 3 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 10
battery modules (to the UPS or to the other battery modules) Connectors for communicating with an additional battery module 4 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 11
date has passed and the batteries were never recharged, do not use the UPS. Contact your service representative. 3.2 Unpacking the Cabinet Unpacking the UPS in a low-temperature environment may cause condensation gas, and corrosion. Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 5 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 12
for Input 4 LXE communication card (optional) standard on network bundle models 5 RS232 communication cable 6 USB communication cable 7 89 2 STATUS CONFIG RESET 4 7 Safety instructions 8 Quick start guide 9 LXE card user guide 10 LXE card data cable 6 Eaton Tripp Lite SmartOnline Series User - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 13
, attached with battery detection cable 2 Stabilizer bracket (4 screws included) 3 Rack kit for 19-inch enclosures 4 EBM Installation manual (Quickstart) 2 3 1 4 NOTE 1 NOTE 2 NOTE 3 Discard the EBM user's guide if you are installing the EBM with a new UPS at the same time. Use the UPS user - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 14
Installation 3.5 Rack Installation NOTE It is remove the UPS internal battery pack before attempting to install the UPS in a rack. See Figure 13 for instructions on how to remove the battery pack. Follow steps 1 to 5 to mount the UPS onto the rails. NOTE Eaton supplies the rack mounting rails - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 15
. Do not make unauthorized changes to the UPS; otherwise, damage may occur to your equipment and void your warranty. Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 9 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 16
Size 4-16 mm2 (12-6 AWG) 6 mm2 (10 AWG) 105° C 10 mm2 (8 AWG) 75°C 10 lb in / 1.13 Nm 10 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 17
relief. 3. Connect the battery detection cable(s) to the UPS connector and the EBM(s). Figure 7. SmartOnline Rack / Tower EBM Connections Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 11 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 18
ground wire first. If you ordered additional equipment, refer to the specific user manual to check the terminal blocks connection of the UPS with this accessory. 1 Insert UPS accessories, refer to their specific user manuals to check the connection to the UPS. OUTPUT N(L2) L1 12 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 19
on Battery Mode. On The UPS is on Bypass Mode. On The UPS has an active alarm or fault. Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 13 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 20
on Battery Mode. The UPS is powering the equipment with the battery power. Prepare your equipment for shutdown. 14 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 21
BATTERY VOLTAGE screen tracks the charge level of your connected battery bank in terms of voltage and charge percentage. Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 15 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 22
. The clear event log command is used to clear the event log. Used to reset the power usage. 16 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 23
for all menus, status and alarms. The UPS fault, event log data and settings are in all supported languages. Enables or disables the audible alarm. Sets the UPS output voltage. The UPS must be in standby is OFF. If Enabled, LCD and Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 17 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 24
. Sets events or faults that actuate the output signal through the external contact connector or RS232 communications port. 18 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 25
command returns the UPS to Online Mode. The BATTERY TEST command is used to initiate the UPS battery test. Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 19 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 26
LEVEL BAT LOW TIME REMOTE ON/OFF REMOTE PWR OFF INPUT DB9-4 OUTPUT RELAY OUTPUT DB9-1 OUTPUT DB9-7 20 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 Display Information or Menu function The RESET FAULT ST command is used to reset all faults. But some faults may not - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 27
on bypass Pin 2: load not protected Pin 3: not low battery Pin 6: on bypass Pin 7: low battery Pin 8: load protected Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 21 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 28
installed in the RPO port on the UPS even if the RPO function is not utilized. RPO Connections: 22 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 29
WEBCARDLXE network card, which provides monitoring and control using an SNMP network management platform, web browser, SSH, or Telnet. Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 23 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 30
Software suite can automatically shut down your computer system to protect your data before the UPS shutdown occurs. 24 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 31
Operation NOTE If you ordered a transformer module or other accessory, refer to the specific user manual of that accessory to check the startup sequence of the UPS with the accessory. To start ) to switch off the utility power. Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 25 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 32
UPS Shutdown 26 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 33
protected if the Bypass Standby setting is enabled. The battery recharges when necessary and the communication ports are powered. Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 27 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 34
the most recent event listed first. Press the esc button twice to return to the UPS home menu. 28 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 35
disconnected and the UPS is turned off. The batteries are rated for a 3-5 year service life. The length of service life varies, depending on the frequency of use and ambient temperature (product life divided by supply circuit). Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 29 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 36
connectors. A ribbon cable connects the LCD control panel to the UPS. Do not pull or disconnect the cable. 30 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 37
slide the pack out slowly onto a flat and stable surface. Use two hands to support the battery pack. See 7.4 Recycling The Used Equipment for proper disposal. 6. Verify that as important operating and maintenance instructions. This symbol indiTchaitsessythmabtoyloiundsihcoautelds nthoat Guide - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 38
Recycling The Used Equipment 32 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 39
Troubleshooting 8.1 Typical Alarms and Faults The Eaton Tripp Lite Series UPS alerts you to whenever potential operating problems short circuit. Use the following troubleshooting chart to determine the UPS alarm your service service representative. The batteries need charging or service - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 40
airflow around the UPS is not restricted. Restart the UPS. If the condition persists, contact your service representative. The input source is not connected correctly. Check the input connections. The Remote Power silencing. 34 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 41
service representative Please have the following information ready when you call Eaton Support: • Model number • Serial number • Version number (if available) • Date of failure or problem • Symptoms of failure or problem from Eaton Support or your Support for the dealer or distributor - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 42
Service and Support 36 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 43
Dimensions (inch/mm) DxWxH 28.4 x 17.3 x 5.1 / 722 x 440 x 130 28.4 x 17.3 x 5.1 / 722 x 440 x 130 25.4 x 17.3 x 5.1 / 645 x 440 x 130 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 37 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 44
-linear load Online mode: 0 ms (no break) High-Efficiency mode: 10 ms maximum (due to loss of utility) 38 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 45
batteries -25 to 55°C (-13 to 130°F) without batteries -25 to 55°C (-13 to 130°F) 0 to 96% no condensing Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 39 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 46
180Vdc BP180RT: 180Vdc Sealed, maintenance-free, valve-regulated, lead-acid, with minimum 3-year float service life at 25 °C (77 °F). Lifetime is reduced above 25° C (77° F) Advanced jumper (normally open or normally closed) 40 Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 47
Model Specifications Eaton Tripp Lite SmartOnline Series User Guide 614-40204-Rev 01 41 - Tripp Lite SU6000RTMB | Eaton Tripp Lite SmartOnline Series Rack / Tower Advance - Page 48
614-4020401 614-40204 01
p/n:614-40204
Revision01
SU5000RT
SU6000RT
BP180RT
Rack/TowerAdvancedUser’sGuide
Eaton Tripp Lite SmartOnline Series