Tripp Lite SMX1500XLRT2U Owner's Manual for 230V 2U Rackmount UPS Systems 9331 - Page 11

TEST Icon, RUNTIME Icon, MIN Icon, VWA Icon, K Icon

Page 11 highlights

Basic Operation continued INPUT Icon: Indicates that the 3-digit value displayed is the Input Voltage. OUTPUT Icon: Indicates that the 3-digit value displayed is the Output Voltage. LOAD Icon: Displayed in two modes: 1. Displayed in conjunction with the % icon and 3-digit value to indicate the load percentage. 2. Displayed in conjunction with KWH/Day and 3-digit value to indicate daily power consumption. 3. Both the LOAD icon and Warning icon will flash to indicate an overload. BATT Icon: Displayed in two modes: 1. BATT icon (displayed in conjunction with % icon and 3-digit value) indicates the Battery Capacity %. 2. BATT icon is shown with TEST icon to indicate self-test mode or control mode. % Icon: Indicates units of %. TEST Icon: Displayed in conjunction with BATT icon to indicate that the UPS is performing a self-test. RUNTIME Icon: Displayed in conjunction with the MIN icon and 3-digit value to indicate Runtime in minutes. MIN Icon: Indicates units of minutes. 1. Displayed in conjunction with RUNTIME icon and 3-digit value to indicate battery runtime in minutes. 2. Displayed in conjunction with the 3-digit value (reporting "LCD") to indicate the minimum brightness. VWA Icon: This is a multipurpose icon which indicates units of Volts, VA, Watts, or Amps (V, VA, W, or A will be shown). K Icon: Displayed in conjunction with the W to indicate Kilowatts. It is also used in conjunction with the WH and /DAY icons to indicate Kilowatt Hours per Day. H and /DAY Icons: Displayed in conjunction with "K" and "W" icons to indicate Kilowatt Hours per day (KWH/DAY). Sensitivity Icon: Displayed to set the AC input line sensitivity setting. Sensitivity settings available are 100% (Normal = Full Counter clockwise POT), 50% (half delay), and 25% (full delay = full Clockwise POT). SCROLL Icon: When enabled, the display will automatically cycle through each DISPLAY mode of the LCD once per two-second interval. If a button is pressed while Scroll Mode is enabled, the scroll function will pause for 10 seconds to allow the user to manually make menu selections before resuming scroll. 11 12-10-345-93-3184.indb 11 12/14/2012 11:32:06 AM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

11
Basic Operation
continued
INPUT Icon:
Indicates that the 3-digit value displayed is the Input Voltage.
OUTPUT Icon:
Indicates that the 3-digit value displayed is the Output Voltage.
LOAD Icon:
Displayed in two modes:
1. Displayed in conjunction with the % icon and 3-digit value to indicate the
load percentage.
2. Displayed in conjunction with KWH/Day and 3-digit value to indicate daily
power consumption.
3. Both the LOAD icon and Warning icon will flash to indicate an overload.
BATT Icon:
Displayed in two modes:
1. BATT icon (displayed in conjunction with % icon and 3-digit value) indicates
the Battery Capacity %.
2. BATT icon is shown with TEST icon to indicate self-test mode or control
mode.
% Icon:
Indicates units of %.
TEST Icon:
Displayed in conjunction with BATT icon to indicate that the UPS is
performing a self-test.
RUNTIME Icon:
Displayed in conjunction with the MIN icon and 3-digit value to
indicate Runtime in minutes.
MIN Icon:
Indicates units of minutes.
1. Displayed in conjunction with RUNTIME icon and 3-digit value to indicate
battery runtime in minutes.
2. Displayed in conjunction with the 3-digit value (reporting “LCD”) to indicate
the minimum brightness.
VWA Icon:
This is a multipurpose icon which indicates units of Volts, VA, Watts,
or Amps (V, VA, W, or A will be shown).
K Icon:
Displayed in conjunction with the W to indicate Kilowatts. It is also
used in conjunction with the WH and /DAY icons to indicate Kilowatt Hours per
Day.
H and /DAY Icons:
Displayed in conjunction with “K” and “W” icons to indicate
Kilowatt Hours per day (KWH/DAY).
Sensitivity Icon:
Displayed to set the AC input line sensitivity setting.
Sensitivity settings available are 100% (Normal = Full Counter clockwise POT),
50% (half delay), and 25% (full delay = full Clockwise POT).
SCROLL Icon:
When enabled, the display will automatically cycle through each
DISPLAY mode of the LCD once per two-second interval. If a button is pressed
while Scroll Mode is enabled, the scroll function will pause for 10 seconds to
allow the user to manually make menu selections before resuming scroll.
12-10-345-93-3184.indb
11
12/14/2012
11:32:06 AM