Uniden BC72XLT English Owners Manual - Page 22
Reg. Alk. Batt./ni-mh, Batt., Ni-mh Batt., Reg. Alk. Batt./ni-mh Batt., Reg. Alk. Batt., Reg. Alk.
UPC - 050633650394
View all Uniden BC72XLT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
BC72 Paper OM.fm Page 22 Monday, October 25, 2004 3:11 PM WARNING! Do not connect either adapter to the scanner if nonrechargeable batteries (such as alkaline batteries) are installed in the scanner and REG. ALK. BATT./NI-MH BATT. is set to NI-MH BATT., or if you are unsure of the switch's position. Non-rechargeable batteries will get hot and can even burst if you try to recharge them. Before you use Ni-MH or Ni-Cd batteries for the first time, charge them for 14 hours to bring them to a full charge. Discharged batteries take about 14 hours to fully recharge. Notes: • The scanner might test rechargeable batteries when you install them. TSt CHArg and appear. If the batteries are good, TSt disappears and the scanner charges the batteries. Otherwise, no bAtt appears and the scanner does not charge the batteries. • Ni-MH batteries last longer and deliver more power if you occasionally let them fully discharge. To do this, simply use the scanner until it beeps every 15 seconds and flashes. • To prevent damage to Ni-MH batteries, never charge them in an area where the temperature is above 113°F (45°C) or below 40°F (4°C). • If you connect an external power source to the scanner with REG. ALK. BATT./NI-MH BATT. set to REG. ALK. BATT., CHArg and appear but the scanner does NOT charge the batteries. Make sure that you use the correct batteries and set REG. ALK. BATT./ NI-MH BATT. to the correct position when you connect an external power source. Setting Up Your Scanner 22