Replacing the lamp Turn the power off and disconnect the projector from the power outlet. • To reduce the risk of electrical shock, always turn the projector off and disconnect the power cord before changing the lamp. • To reduce the risk of severe burns, allow the projector to cool for at least 45 - ViewSonic Pro9510L - 1024 x 768 Resolution 6 200 ANSI Lumens 1.3 - 2.21:1 Throw - Page 3
timer after new lamp is installed. • After powering on the projector, open the OSD menu. Go to ADVANCED > Advanced > Lamp Hour Reset, "Please see user manual " message shown on screen when you press Enter button. Then press buttons to reset the lamp hour to "0". CAUTION • Do not reset if the lamp - ViewSonic Pro9510L - 1024 x 768 Resolution 6 200 ANSI Lumens 1.3 - 2.21:1 Throw - Page 4