Viking RDSCE230 Installation Instructions

Viking RDSCE230 Manual

Viking RDSCE230 manual content summary:

  • Viking RDSCE230 | Installation Instructions - Page 1
    Installation Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Website at vikingrange.com UL C UL F20942A EN (060712) Freestanding 30" Electric Range
  • Viking RDSCE230 | Installation Instructions - Page 2
    24 Service & Registration 25 2 IMPORTANT-Read and Follow! • Before beginning, please read these instructions completely and of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the
  • Viking RDSCE230 | Installation Instructions - Page 3
    of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture. • Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below. If the use of a GFI
  • Viking RDSCE230 | Installation Instructions - Page 4
    rating Left front Left rear Center Right front Right rear Oven interior width Oven interior height Oven interior depth Oven volume Approximate shipping weight RDSCE230-5B 29-7/8" (75.9 cm) To top of glass frame 35-7/8" (91.1 cm) min. to 37" (94.0 cm) max. Legs adjust 1-1/8" (2.9 cm) To end of side
  • Viking RDSCE230 | Installation Instructions - Page 5
    bottom of the hood being WoodO/Cveormlapyosite 66" (167.6 cm) to 72" (182.9 cm) above the floor. Refer to the range hood installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood. Note: Minimum clearance for back wall is 0" with
  • Viking RDSCE230 | Installation Instructions - Page 6
    of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture. Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below. If the use of a GFI
  • Viking RDSCE230 | Installation Instructions - Page 7
    . If you notice the cooling fan is not operating or you observe unusual or excessive noise coming from the cooling fan, contact a Viking Authorized Service Center before continuing operation. Failure to do so can result in damage to the oven or surrounding cabinets. Moving, Handling, and Unpacking
  • Viking RDSCE230 | Installation Instructions - Page 8
    and internal mounting hardware. 14 Electrical Connection (3-wire) Note: If you have a 4-wire connection, see following section for 4-wire connection instructions. WARNING Electrical shock hazard. To avoid risk or electrical shock, personal injury or death; grounding product to the frame of the
  • Viking RDSCE230 | Installation Instructions - Page 9
    Electrical Connection (3-wire) (cont.) Bare Wire Connection Eyelet Connection 4 1 1 To make a bare wire connection, use holes on the left side of the terminal block. To connect eyelet style wires, use holes on right side of terminal. 5 1 1 2 Attach line #1 (black) and line #2 (red) leads to
  • Viking RDSCE230 | Installation Instructions - Page 10
    Electrical Connection (4-wire) (cont.) Bare Wire Connection Eyelet Connection 4 1 1 To make a bare wire connection, use holes on the left side of the terminal block. To connect eyelet style wires, use holes on right side of terminal. 5 Feed supply cord up through hole in bottom of range back
  • Viking RDSCE230 | Installation Instructions - Page 11
    Leveling/Adjustments/Alignment (cont.) 7 Set the high corner of range so that the top of side trim is 3/8" (0.95 cm) above countertop. Level range to high corner. Anti-tip Device Installation WARNING TIPPING HAZARD • THIS RANGE CAN TIP. • A CHILD OR ADULT CAN TIP THE RANGE AND BE KILLED. • FAILURE
  • Viking RDSCE230 | Installation Instructions - Page 12
    Floor Mount Anti-tip Installation (cont.) 3 4 1 2 x2 Remove two screws from back of range. 5 1 2 Attach bracket to back of range using two screws. Final Installation Note: Refer to range electrical requirements section for proper installation information. Slide range into place and check
  • Viking RDSCE230 | Installation Instructions - Page 13
    under the control panel. Record the following information indicated below. You will need it if service is ever required. Model number Serial number Date of purchase Date installed Dealer's name Address These installation instructions should remain with the unit for future reference. 25
  • Viking RDSCE230 | Installation Instructions - Page 14
    26 27
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

Installation
Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information, call 1-888-VIKING1 (845-4641)
or visit the Viking Website at vikingrange.com
F20942A EN
(060712)
U
L
C
U
L
Freestanding 30” Electric Range