    Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com F20470I EN (082012) Professional & Outdoor Hoods
  • Viking VBCV60381 | Installation Instructions - Page 2
    leave these instructions with the servicing or cleaning. Viking hoods are equipped with variable speed control blowers. These units will not function with a single speed ventilator. All Viking Range ventilator kits are designed specifically for use with Viking Range hoods. Use of any non-Viking Range
  • Viking VBCV60381 | Installation Instructions - Page 3
    IMPORTANT-Please Read and Follow! WARNING To reduce the risk of injury to persons in the event of a rangetop grease fire, observe the following. (Based on "Kitchen Firesafety Tips," published by NFPA.) 1. SMOTHER FLAMES with a close fitted lid, cookie sheet, or metal tray, then turn off the burner.
  • Viking VBCV60381 | Installation Instructions - Page 4
    Clearance Dimensions (VWH 10"H. Wall Hoods w/Standard Ventilator) 6 Interior Ventilator Dimensions (VWH 10"H. Wall Hoods w/Standard Ventilator) Top View 460 CFM Interior Ventilator Installation 7
  • Viking VBCV60381 | Installation Instructions - Page 5
    cm) 4 4 2 VINV1200* DEV1200*/ 1500** DIL1200 10" (25.4 cm) 11.5 8.9/9.2 10.7 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct
  • Viking VBCV60381 | Installation Instructions - Page 6
    Interior Ventilator Dimensions (VWH 18"H. Wall Hoods) Top View Exterior Ventilator Dimensions (VWH 18"H. Wall Hoods) Top View 300 or 600 CFM Interior Ventilator Installation for all Wall Hoods Top View 1200 CFM Interior Ventilator Installation for all Wall Hoods 10 900 or 1200 CFM Exterior or In-
  • Viking VBCV60381 | Installation Instructions - Page 7
    or exterior-power ventilator should be used with all T-Series models and when indoor models are installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 covered with locally-supplied stainless steel. Viking also recommends using a backsplash. 13
  • Viking VBCV60381 | Installation Instructions - Page 8
    11.9 8.5/9.2 In-Line-Maximum amps 6.0/7.9 6.0/7.9 6.0/7.9 10.3 10.3 10.7 10.7 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with
  • Viking VBCV60381 | Installation Instructions - Page 9
    Interior Ventilator Dimensions (VCWH Chimney Wall Hoods) Top View 300 or 600 CFM Interior Ventilator Installation for 30", 36", & 42" models Top View 1200 CFM Interior Ventilator Installation for 48", 54", 60", & 66" models 16 Exterior Ventilator Dimensions (VCWH Chimney Wall Hoods) Top View 900 or
  • Viking VBCV60381 | Installation Instructions - Page 10
    28" (71.1 cm) 3 3 VINV1200* DEV1200*/1500** DIL1200 10" (25.4 cm) 7.3 4.3/5.1 6.1 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer
  • Viking VBCV60381 | Installation Instructions - Page 11
    Interior Ventilator Dimensions (DCWH Classic Chimney Hoods) Top View 300 or 600 CFM Interior Ventilator Installation for 30", 36", & 42"Hoods Top View 1200 CFM Interior Ventilator Installation for 48" Hoods 20 Exterior Ventilator Dimensions (DCWH Classic Chimney Hoods) Top View 900 or 1200 CFM
  • Viking VBCV60381 | Installation Instructions - Page 12
    -Maximum amps 4.6 7.4/4.7 4.7/6.5 10" (25.4 cm) 4.6 8.9 7.4/4.7/5.5 5.6/6.4 3.9/5.7 7.4 9.3 6.4/7.4 7.4 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM
  • Viking VBCV60381 | Installation Instructions - Page 13
    Interior Ventilator Dimensions (VCIH Chimney Island Hoods) Top View 600 CFM Interior Ventilator Installation for all Chimney Island Hoods Top View 1200 CFM Interior Ventilator Installation for all Chimney Island Hoods 24 Exterior Ventilator Dimensions (VCIH Chimney Island Hoods) Top View 900 or
  • Viking VBCV60381 | Installation Instructions - Page 14
    11.9 8.9/9.2 In-Line-Maximum amps 6.0/7.9 6.0/7.9 6.0/7.9 10.3 10.3 10.7 10.7 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with
  • Viking VBCV60381 | Installation Instructions - Page 15
    Clearance Dimensions (VBCV Wall Custom Ventilator System) 28 Built-In Wall Custom Ventilator System Dimensions (VBCV Models) For 900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation For 300, 600 or 1200 CFM Interior Ventilator Installation 900 or 1200 CFM Exterior or In-Line
  • Viking VBCV60381 | Installation Instructions - Page 16
    for hoods includes recommended ventilator kit rating; all products must be hard wired direct with 2-wire with ground. Plan where the duct work will be located. measurements for various heights of ceilings, soffits, cabinets, or ranges/rangetops. Check Framing NOTE: Because of the weight of the
  • Viking VBCV60381 | Installation Instructions - Page 17
    . If you have any questions, contact the manufacturer. • Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device
  • Viking VBCV60381 | Installation Instructions - Page 18
    . If you have any questions, contact the manufacturer. • Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device
  • Viking VBCV60381 | Installation Instructions - Page 19
    Installation (VWH 18"H. Wall & VCWH Chimney Wall Hoods) Connect black to black, white to white, and the green/bare wire under the green screw. NOTE: Housing wiring must be properly installed for wiring to be correct when wiring unit. Replace electrical box cover. Make connection to breaker box.
  • Viking VBCV60381 | Installation Instructions - Page 20
    Duct Cover Option (VCWH Chimney Wall Hoods) Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip. Slide filter front over front lip. Push filter rear up, then slide back over rear lip. Duct Cover Option (VWH 18"H. Wall Hoods) Measure distance from ceiling to
  • Viking VBCV60381 | Installation Instructions - Page 21
    rear up, then slide back over rear lip. Attach duct cover to ceiling. The ceiling bracket can be hidden by using a locally supplied trim. Additional support option. Drill holes in all four corners for threaded rod and run rods from hood to ceiling. 40 Slide spacer front over front lip. Push
  • Viking VBCV60381 | Installation Instructions - Page 22
    Installation (DCWH Classic Chimney Wall Hoods) Measure down 1-13/16 (4.6 cm) from desired height of hood and secure 1-1/2" x 3/4" wood strip (not included) to wall using screws provided. Use additional mounting screws to secure hood to wood strip. Slide filter front over front lip. Push filter
  • Viking VBCV60381 | Installation Instructions - Page 23
    & Parts Only authorized replacement parts may be used in performing service on the appliance. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician. Record the following information indicated
  • Viking VBCV60381 | Installation Instructions - Page 24
    46 47
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

F20470I EN
(082012)
Viking Installation Guide
Professional &
Outdoor Hoods
Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-VIKING1 (845-4641)
or visit the Viking Web site at
vikingrange.com