Weber Genesis 5000 LP Owner Manual

Weber Genesis 5000 LP Manual

Weber Genesis 5000 LP manual content summary:

  • Weber Genesis 5000 LP | Owner Manual - Page 1
    other appliance. WARNING: Do not try to light this appliance without reading "Lighting" instructions section of this manual. THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY. FOR YOUR SAFETY If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open flame. 3. Open lid. 4. If odor
  • Weber Genesis 5000 LP | Owner Manual - Page 2
    before using. See instructions in this manual for correct procedures. s Do not operate the Weber Gas Barbecue if there is a gas leak present. s Do not use a flame to check for gas leaks. s Combustible materials should never be within 24 inches of the top, bottom, back or sides of your Weber
  • Weber Genesis 5000 LP | Owner Manual - Page 3
    of this Weber Gas Barbecue that it and operated in accordance with the printed instructions accompanying it. Weber may require reasonable proof prove defective under normal use and service and which on examination shall indicate set out in this owner's manual. Deterioration or damage due to
  • Weber Genesis 5000 LP | Owner Manual - Page 4
    , and Warm-Up are U.S. trademarks of Weber-Stephen Products Co., 200 East Daniels Road, Palatine, IL 60067-6266. Spirit 500, 700, and Genesis 1000-5500 Gas Barbecues are covered under one or more of the following patent nos.: U.S. patent #4,677,964; #4,727,853; #4,777,927; #4,829,978; #4,860,724
  • Weber Genesis 5000 LP | Owner Manual - Page 5
    Instructions 6 Assembly 7-28 Operating Instructions Lighting 29-30 Cooking 31 Storage and/or Nonuse 31 Cleaning 31 Steam-N-Chips Smoker 32 Troubleshooting & Maintenance Annual Maintenance 33 General Maintenance 34-36 Troubleshooting with Gas System automatically shuts off gas to the burners
  • Weber Genesis 5000 LP | Owner Manual - Page 6
    Gas Barbecue with you if you move. Liquid Propane (LP) gas supply is easy to use and gives you more cooking control than charcoal fuel. s These instructions not use combustible materials within 24 inches of the top, bottom, back or sides of the grill. s The entire cooking box gets hot when in use.
  • Weber Genesis 5000 LP | Owner Manual - Page 7
    ) Hose Supplies needed You will need a soap and water solution to check for gas leaks. (See Step "Check for gas leaks"). Note - The hardware size of nuts, bolts and screws is given. . Call the Weber Customer Service Center toll free 1-800-446-1071 to receive immediate assistance. Have your owner
  • Weber Genesis 5000 LP | Owner Manual - Page 8
    Work table Left frame Two swing tables Wheel frame Brace panel Left end panel (#1) 1 Panels and doors are identified with removable stickers. Please leave on during assembly. Five long Flavorizer Bars ER Two wheels WE B ER WE B 2 Three back panels (#2) Frame connector 3 Right end panel
  • Weber Genesis 5000 LP | Owner Manual - Page 9
    Seven short Flavorizer Bars Catch pan holder Catch pan Two drip pans Thermometer Right hand slide bar assembly Assembly consists of: Right hand slide bar Support rod Slide Left hand slide bar assembly Assembly consists of: Left hand slide bar
  • Weber Genesis 5000 LP | Owner Manual - Page 10
    assembly Burner grate Side burner knob Two side burner locks Check contents of hardware packs Four 10-24 x 1 3/4 inch machine screws (actual size) Twenty three 1/4 inch nylon washers (actual size) Four 10-24
  • Weber Genesis 5000 LP | Owner Manual - Page 11
    block of wood (or other protected surface). Tap on one hubcap. Put one wheel on the axle, WEBER side toward the hubcap. Slide the axle through the frame. Add the other wheel, WEBER side out. Tap on the hubcap. Figure 1. ER WE B ER WE B Step 3 Assemble frame You will need: left frame
  • Weber Genesis 5000 LP | Owner Manual - Page 12
    with bushings, one frame connector without bushings, four 1/4-20 x 2 inch bolts, four nylon washers and a 7/16 inch wrench. Hold the frame connector, bushing side down, between the caster and wheel frame, above the front panel. Add nylon washers to the bolts, put the bolts through the frame and
  • Weber Genesis 5000 LP | Owner Manual - Page 13
    Step 6 Insert casters You will need: frame assembly and two casters. Push the casters firmly into the caster inserts in the ends of the caster legs. Figure 5. Step 8 Install left end panel You will need: frame assembly and left end panel. (Number 1) Place the bottom of the left end panel on the
  • Weber Genesis 5000 LP | Owner Manual - Page 14
    lock. The "U" shape cut out of the lock slips down over the bolt. Tighten with a wrench. Figure 10. Loosen the right front 1/4 x 20 bolt. The side burner lock fits between the front panel and the frame. The "U" shape cut out slips up over the bolt. Tighten with a wrench. Figure 8 With all
  • Weber Genesis 5000 LP | Owner Manual - Page 15
    brace. Figure 11. Burner tubes Frame brace Figure 11 Your Weber Gas Barbecue burner assembly has been factory assembled, pressure and flame tested. at the left rear and left front of the cooking box? The screws are only guides. Do not tighten. Figure 13 (b). c) Are the wing nuts under the burner
  • Weber Genesis 5000 LP | Owner Manual - Page 16
    installations. Refer to ANSI Z223.1 latest edition for complete specifications. Note: The LP gas supply at the barbecue must be regulated to 10.5 inches of water column pressure. s A manual shut-off valve must be installed outdoors, immediately ahead of the quick disconnect. ƽCAUTION: If young
  • Weber Genesis 5000 LP | Owner Manual - Page 17
    fitting to keep it from becoming loose. If the side burner fitting should loosen, tighten before attaching side burner hose. Side burner fitting Step 14 Connect flexible hose to manifold You will need: the 12 foot gas supply hose and a 3/4 inch wrench. Thread fitting end of hose onto manifold
  • Weber Genesis 5000 LP | Owner Manual - Page 18
    17 Install brace panel You will need: brace panel. Slide the side burner back. Insert the tabs into the slots in the frame brace at the wheel legs. (Make sure the side burner hose is to the front of the barbecue.) Figure 20 (a). Slide up
  • Weber Genesis 5000 LP | Owner Manual - Page 19
    1/4-20 wing nut and a 7/16 inch wrench. Set the right end panel over the brace panel. Make sure the gas supply hose is on the outside of the panel. Put the washer on the 1/4-20 x 1 1/2 inch bolt and the brace panel. Put on wing nut and tighten. Figure 22. Side burner hose Figure 22 Figure 21 19
  • Weber Genesis 5000 LP | Owner Manual - Page 20
    two accessory trays between the two frame connectors. Figure 23. Figure 23 Step 20 Install igniter Note - The igniter wires are already attached to the Gas Catcher Ignition Chamber and the igniter. This was done to factory test the ignition system. The igniter lock nut is on the igniter. Insert the
  • Weber Genesis 5000 LP | Owner Manual - Page 21
    bracket is in any way cracked or damaged, do not use swing table. Call our Customer Service Center to order a new part. ƽWARNING: The load limit for the swing table is 30 pounds. (b) (c) Support rod (a) Figure 25 Hinge rod (a) (b) View from rear of barbecue (c) Figure 26 Slot in frame (view
  • Weber Genesis 5000 LP | Owner Manual - Page 22
    screws, right hand slide bar assembly, swing table, four nylon washers, screwdriver and pliers. Allow the slide bar to hang down. Push the support rod into the lower support bracket. Figure 29 (a). Swing the rod up so you can slide the rod all the way inside the locking tab. Figure 29 (b). The
  • Weber Genesis 5000 LP | Owner Manual - Page 23
    is in any way cracked or damaged, do not use swing table. Call our Customer Service Center to order a new part. ƽWARNING: The load limit for the swing table is View from rear of barbecue Hinge rod To lower table: Pull support rod up to disengage slide lock and lower table. To raise table, lift
  • Weber Genesis 5000 LP | Owner Manual - Page 24
    leaks before using your Weber Genesis Gas Barbecue. Shipping and handling may have loosened or damaged a gas fitting. ƽWARNING: Perform these leak connections should be rinsed with water after checking for leaks. Make sure side burner is OFF. Remove valve control knob and screws. Remove porcelain top
  • Weber Genesis 5000 LP | Owner Manual - Page 25
    with soap and water solution. If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact your dealer. c) Side burner hose to side burner connection. Figure 36 (c). d) Valves to manifold connections. Figure 36 (d). e) Hose to quick disconnect connection
  • Weber Genesis 5000 LP | Owner Manual - Page 26
    The wide cooking grate goes to the right, narrow grate goes to the left side of the cooking box. Set the cooking grates onto the ledges in the cooking box pan and one drip pan. Finger grip on front edge of bottom tray Front side of catch pan holder Figure 40 Hook the ends of the catch pan holder
  • Weber Genesis 5000 LP | Owner Manual - Page 27
    and FlameCheck button. Figure 44 (b). Hole in frame brace (a) Step 29 Secure side burner Pull the right hand swing table up. Stand to the right side of the barbecue. Slightly pull back both side burner locks. Slide the side burner toward the control panel. The locks will snap into the slots in the
  • Weber Genesis 5000 LP | Owner Manual - Page 28
    the lid and the other end into the slot in the left end of the lid. Figure 47 (a). Set the work table onto the left side rails. Figure 47 (b). Place porcelain serving tray on the work table. Figure 47 (c). Set the warming rack into the slots at the rear of the
  • Weber Genesis 5000 LP | Owner Manual - Page 29
    instructions are on the control panel. ƽ DANGER ƽ Failure to open lid while igniting the barbecue, or not waiting 5 minutes to allow the gas from WeberStephen Products Co., Customer Service Center or authorized dealer. Crossover Ignition System 1 2 6 745 8 3 3) Turn gas supply valve on. 4) Push
  • Weber Genesis 5000 LP | Owner Manual - Page 30
    lighting the barbecue. 5) Push down and hold the FlameCheck button down. 1 Manual Lighting 8) After the FRONT burner is lit you can turn on the other Failure to open lid while igniting the side burner, or not waiting 5 minutes to allow gas to clear if the side burner does not light, may result in
  • Weber Genesis 5000 LP | Owner Manual - Page 31
    at medium). See your Weber cookbook for detailed cooking instructions. If burners go out during cooking, open lid, Storage and/or Nonuse s When storing the Weber Gas Barbecue, make sure that the inside shut off valve retailer or the Weber-Stephen Customer Service Center. Outside surfaces - Use a
  • Weber Genesis 5000 LP | Owner Manual - Page 32
    of ash to allow proper air flow. Accomplish this by lightly tapping the sides of the smoker and stirring the ashes so that they sift through the used to enhance any of the meat, poultry and fish recipes in the gas barbecue cookbook. Cook with the lid down according to the times indicated in charts
  • Weber Genesis 5000 LP | Owner Manual - Page 33
    Order from WeberStephen Products Co., Customer Service Center or authorized dealer. s Inspect this manual. s Check all gas fittings for leaks. ƽ DANGER ƽ Do not use an open flame to check for gas leaks manifold connection. Figure 5 (a). b) Manifold to side burner hose connection. Figure 5 (b). (e)
  • Weber Genesis 5000 LP | Owner Manual - Page 34
    the venturi section of the burner tubes. This blocks the normal gas flow, and can cause the gas to flow back out of the air shutter. Figure 6. This the burner cleaning procedures. Main Burner Cleaning Procedure Turn off the gas supply. Remove the manifold. (See Section "Replacing the main burners
  • Weber Genesis 5000 LP | Owner Manual - Page 35
    must be OFF and cool. b) Turn gas OFF at the source. c) Remove control panel: take off screws Figure 12 g) Slide the burner assembly out from under the guide screw and washer in the corners of the cooking box. Figure 13. Guide screw h) Lift and twist the burner assembly slightly, to separate the
  • Weber Genesis 5000 LP | Owner Manual - Page 36
    probe senses the heat from the Front burner, and activates the FlameCheck valve. The valve allows the gas to flow into the Front burner. If the Front burner should go out for any reason, the the Crossover Ignition System still fails to light, see Section "Manual Lighting", and contact your dealer. 36
  • Weber Genesis 5000 LP | Owner Manual - Page 37
    TROUBLESHOOTING Problem Check Burners burn with a yellow or orange flame, in Inspect Weber Spider Stopper conjunction with the smell of gas. Guards for possible obstructions. (Blockage of holes.) Cure Clean Weber Spider Stopper Guards. (See Section "Annual Maintenance".) Burner does not
  • Weber Genesis 5000 LP | Owner Manual - Page 38
    ƽWARNING: Before attempting any troubleshooting steps, all gas controls and supply valves should be in the OFF position. Problem Side burner does not light. Check Is gas supply off? Is the Front burner on? Cure Turn supply on. Light front burner. Flame is low in HIGH position. Is
  • Weber Genesis 5000 LP | Owner Manual - Page 39
    39
  • Weber Genesis 5000 LP | Owner Manual - Page 40
    1 2 3 4-6 7 8 9 10 11 12 13 14 15 16 17 18 19-20 21 22-24 25 26 27 28 29 30 31 32 ® ® 2 2 2 1 3 LH RH RH E BE R W E BE R W 33 34 35 36 47 23 37 38 39 40 41 42 43 43 44 45 19 46 24 40 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67-70 17 18 71
  • Weber Genesis 5000 LP | Owner Manual - Page 41
    38 Front panel 39 Frame connector 40 Wheel frame Contact: Weber-Stephen Products Co. Customer Service Center 250 South Hicks Road Palatine, IL 60067-6241 (800) 446-1071 41 1/4-20 hex nut 42 1/4-20 wing nut 43 Side burner locks (2) 44 Brace panel 45 Right end panel 46 1/4-20 x 1 1/2 inch bolt 47
  • Weber Genesis 5000 LP | Owner Manual - Page 42
    products, an occasional error may occur. Our knowledgeable Customer Service staff is prepared to help you with any problems with parts or assembly. Call our toll free number 1-800-446-1071. For quicker service, please have your owner's manual available for reference. We also welcome any comments or
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Serial Number
Please use this number in registering your warranty
and any correspondence with the factory.
®
62715
6/96
Owner's Manual
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
NOTICE TO INSTALLER:
These
instructions must be left with the owner
and the owner should keep them for
future use.
WARNING:
Follow all leak check
procedures carefully in this manual prior
to barbecue operation. Do this even if
barbecue was dealer assembled.
WARNING:
Do not try to light this
appliance without reading "Lighting"
instructions section of this manual.
THIS GAS APPLIANCE IS DESIGNED FOR
OUTDOOR USE ONLY.
FOR YOUR SAFETY
If you smell gas:
1.
Shut off gas to the appliance.
2.
Extinguish any open flame.
3.
Open lid.
4.
If odor continues, immediately call
your gas supplier.
GENESIS
®
5000 Series
Propane Fixed Piping System
GAS
BARBECUE