24 OPERATING INSTRUCTIONS 1) Open the lid. 2) Make sure all burner control knobs are turned off. (Push control knob in and turn clockwise to ensure that it is in the "OFF" position.) ƽ WARNING: The burner control knobs must be in the "OFF" position before turning on the liquid propane cylinder tank valve. If they are not in the "OFF" position, when you turn on the LP cylinder valve, the "excess gas flow control" feature will activate, limiting the flow of gas from the LP cylinder. If this should occur, turn off the LP cylinder valve and burner control knobs. Then start over. ƽ DANGER When the "excess gas flow control" feature is activated, a small amount of gas is still flowing to the burners. After turning off the cylinder and burner control knobs, wait at least 5 minutes for the gas to clear before attempting to light the grill. Failure to do so may result in an explosive flare-up, which can cause serious bodily injury or death. 3) Turn the cylinder on by turning the cylinder valve counterclockwise. ƽ WARNING: Do not lean over the open barbecue. 4) Ignite each adjacent Sear Station™ main burner. Push the control knob in and turn to "START/HI" until you hear the igniter snap - continue to hold control knob in for two seconds. This action will spark the igniter, the burner lighting tube and then main burner. 5) Check that the burner is lit by looking through the cooking grates. You should see a flame. If burner does not light on first try, push control knob in and turn to OFF. Repeat lighting procedure a second time. To ignite the Sear Station™ burner continue with Step 6. Sear Burner Lighting: Ignition by an adjacent ignited Main Burner. 6) Turn Sear Station™ burner control knob to the ON position. 7) Verify burner ignition by visual inspection of a flame. ƽ WARNING: If ignition does not occur in 5 seconds, turn burner control OFF, wait 5 minutes, and repeat steps 6 & 7, or see Match Lighting instructions. ƽ WARNING: If the burner still does not light, turn the burner control knob to "OFF" and wait 5 minutes to let the gas clear before you try again or try to light with a match. Note: See Maintenance for burner removal and cleaning procedure. TO EXTINGUISH Push in and turn each burner control knob clockwise to "OFF" position. Turn gas supply off at the source. ARRÊTÉ OFF APAGADO EN MARCHE ON ENCENDIDO B B. OFF A A. ON SEAR STATION™ BURNER LIGHTING 1 5 7 2 4 6 3 *The grill illustrated may have slight differences than the model purchased. 2 6 EN MARCHE ON ENCENDIDO WWW.WEBER.COM®

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

24
WWW.WEBER.COM
®
1
3
5
4
2
6
7
ARRÊTÉ
APAGADO
OFF
EN MARCHE
ENCENDIDO
ON
B
A
B.
A.
OFF
ON
SEAR STATION
BURNER LIGHTING
*The grill illustrated may have slight
differences than the model purchased.
2
6
EN MARCHE
ENCENDIDO
ON
1)
Open the lid.
2)
Make sure all burner control knobs are turned off. (Push control knob in and turn
clockwise to ensure that it is in the “OFF” position.)
±
WARNING: The burner control knobs must be in the “OFF”
position before turning on the liquid propane cylinder tank
valve. If they are not in the “OFF” position, when you turn on
the LP cylinder valve, the "excess gas flow control" feature
will activate, limiting the flow of gas from the LP cylinder. If
this should occur, turn off the LP cylinder valve and burner
control knobs. Then start over.
±
DANGER
When the "excess gas flow control" feature is activated,
a small amount of gas is still flowing to the burners. After
turning off the cylinder and burner control knobs, wait at
least 5 minutes for the gas to clear before attempting to light
the grill. Failure to do so may result in an explosive flare-up,
which can cause serious bodily injury or death.
3)
Turn the cylinder on by turning the cylinder valve counterclockwise.
±
WARNING: Do not lean over the open barbecue.
4)
Ignite each adjacent Sear Station
main burner. Push the control knob in and turn
to “START/HI” until you hear the igniter snap - continue to hold control knob in for
two seconds. This action will spark the igniter, the burner lighting tube and then
main burner.
5)
Check that the burner is lit by looking through the cooking grates. You should see
a flame. If burner does not light on first try, push control knob in and turn to OFF.
Repeat lighting procedure a second time.
To ignite the Sear Station
burner continue with Step 6.
Sear Burner Lighting:
Ignition by an adjacent ignited Main Burner.
6)
Turn Sear Station
burner control knob to the ON position.
7)
Verify burner ignition by visual inspection of a flame.
±
WARNING: If ignition does not occur in 5 seconds, turn
burner control OFF, wait 5 minutes, and repeat steps 6 & 7, or
see Match Lighting instructions.
±
WARNING: If the burner still does not light, turn the burner
control knob to “OFF” and wait 5 minutes to let the gas clear
before you try again or try to light with a match.
Note: See Maintenance for burner removal and cleaning
procedure.
TO EXTINGUISH
Push in and turn each burner control knob clockwise to “OFF” position. Turn gas supply
off at the source.
OPERATING INSTRUCTIONS