    ® 30" and 36" (76.2 cm and 91.4 cm) Wall-Mount Canopy Range Hood PRODUCT MODEL NUMBERS GXW6530DX GXW6536DX ELECTRICAL REQUIREMENTS • A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required. VENTING REQUIREMENTS This canopy hood is factory set for venting through the roof or wall
  • Whirlpool GXW6530DXS | Dimension Guide - Page 2
    (recirculating) Installations * NOTE: The range hood chimneys are adjustable and designed to meet varying ceiling or soffit heights depending on the distance "X" between the bottom of the range hood and the cooking surface. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number
  • 1
  • 2

PRODUCT MODEL NUMBERS
GXW6530DX
GXW6536DX
ELECTRICAL REQUIREMENTS
• A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
VENTING REQUIREMENTS
This canopy hood is factory set for venting through the roof or wall.
A 6" (15.2 cm) round vent system is needed for installation (not included). The
hood exhaust opening is 6" (15.2 cm) round.
NOTE:
Flexible vent is not recommended. Flexible vent creates back pressure and
air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall. To vent through a
wall, a 90° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood
can be used in the non-vented (recirculating) version, fitting a charcoal filter and
the deflector. Fumes and vapors are recycled through the top grille.
30" and 36" (76.2 cm and 91.4 cm) Wall-Mount
Canopy Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10292167C
10/26/10
®
A
A
B
B
B
A
Roof Venting
Wall Venting
Non-vented
(recirculating)
A. Roof cap
B. 6" (15.2 cm)
round vent
A. Wall cap
B. 6" (15.2 cm)
round vent
A. Deflector
B. 6" (15.2 cm)
round vent
20"
(50.8 cm)
30" (76.2 cm) or
36" (91.4 cm)
13
³⁄₁₆
"
(33.5 cm)
10
⁷⁄₈
"
(27.6 cm)
Page 1 of 2
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
Vent Piece
Round
45° elbow
2.5 ft (0.8 m)
90° elbow
5.0 ft (1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
PRODUCT DIMENSIONS
Example vent system
The following example falls within the maximum recommended vent
length of 35 ft (10.7 m).
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
Length of system
= 13.0 ft (3.9 m)
90
elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
*For non-vented (recirculating) installations
**For vented installations
17
³⁄₁₆
" (43.7 cm)
**27
¹⁄₈
" (68.9 cm) min.
**41
¹⁄₈
" (104.5 cm) max.
*27
¹⁄₈
" (68.9 cm) min.
*45
¹⁄₂
" (115.6 cm) max.