- Whirlpool WED4616FW | Dimension Guide - Page 1
. ■■ Additional spacing should be considered for ease of installation and servicing. ■■ Additional clearances might be required for wall, door, and moldings. ■■ Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer. ■■ For closet installation, with a door - Whirlpool WED4616FW | Dimension Guide - Page 2
branch circuit. VENTING REQUIREMENTS Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent m) 5 Rigid metal 70 ft. (21.3 m) Because Whirlpool Corporation policy includes a continuous commitment to improve our products, Instructions packed with product. Specifications
Electric Dryer
PRODUCT MODEL NUMBERS
W10562358A
05/2015
WED4800B, WED4810B, WED4850B, WED4870B, WED5000D,
WED4810E, WED4815E, WED4915E, WED4975E, WED4616F,
WED4916F
29"
(737 mm)
43
3
/
8
"
(1102 mm)
1
/
2
"
(13 mm)
29"
(737 mm)
1
1
/
2
"
(38 mm)
43
3
/
8
"
(1102 mm)
Dryer Dimensions
NOTE:
Leveling legs should be 1/2" (13 mm) (to match height
of 3.6 cu. ft. capacity washer) or 1½" (38 mm) (to match height
of 3.8 cu. ft. capacity washer).
22
3
/
4
"
(578 mm)
27
3
/
4
"
(705 mm)
Wide opening side-swing door
Wide opening hamper door
*Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
Minimum Required Spacing
A
B
C
18"*
(457 mm)
1"
(25 mm)
29"
(737 mm)
1"
(25 mm)
1"*
(25 mm)
14" max.*
(356
mm)
27
¾"
(705 mm)
48 in.
(310 cm )
2
*
2
3"*
(76 mm)
3"*
(76 mm)
24 in.
(155 cm )
2
*
2
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
Minimum spacing for recessed area or closet
installation
The dimensions shown following are for the minimum spacing
allowed.
■
Additional spacing should be considered for ease of
installation and servicing.
■
Additional clearances might be required for wall, door, and
floor moldings.
■
Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
■
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings
are acceptable.
■
Companion appliance spacing should also be considered.
*Additional spacing recommended
27
3
/
4
"
(705 mm)
13
3
/
4
"
(349 mm)