Whirlpool WED5100SQ Dimensions

Whirlpool WED5100SQ Manual

Whirlpool WED5100SQ manual content summary:

  • Whirlpool WED5100SQ | Dimensions - Page 1
    fused on both sides of the line. Use 10 gauge solid copper wire. A time-delay fuse or circuit breaker is recommended. Exhaust venting: Exhaust your dryer to length chart. Determine the number of elbows you will need. Because Whirlpool Corporation policy includes a continuous commitment to improve
  • 1

PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
GEW9878P
LEB6000P
LEB6200P
LEB6300P
LEC5000P
LEC9000P
LEN1000P
LEN2000P
LEQ8000J
LEQ9030P
LEQ9508P
LEQ9858P
LER3624P
LER4600P
LER4610P
LER4634P
LER5636P
LER5644P
LER6620P
LER6636P
LER6646P
LER7648P
LER8620P
LER8648P
WED5100S
WED5200T
WED5300S
WED5310S
WED5500S
WED5520S
WED5530S
WED5540S
WED5550S
WED5600S
WED5700S
WED5790S
WED5800S
WED5800V
WED5810S
WED5820S
WED5830S
WED5840S
WED5850S
WED5900S
Electrical:
A four-wire or three-wire, single phase,
120/240-volt, 60-Hz, AC-only, electrical supply (or
120/208-volt electrical supply, if specified on the
serial/rating plate) is required on a separate 30 amp
circuit, fused on both sides of the line. Use 10
gauge solid copper wire. A time-delay fuse or circuit
breaker is recommended.
Exhaust venting:
Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only.
For complete details, see Installation
Instructions packed with product.
Specifications subject to change without notice.
Ref. 8577188
10-16-08
A. Small opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
43
³⁄₈
"
(110cm)
*26"
(66cm)
29"
(73.66cm)
A
15¼"
(38.74cm)
43
³⁄₈
"
(110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
B
22¾"
(57.8cm)
43
³⁄₈
"
(110cm)
13¾"
(34.9cm)
*27¾"
(70.5cm)
29"
(73.66cm)
D
43
³⁄₈
"
(110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
C
22¾"
(57.8cm)
A
B
C
18"
(45.7 cm)
0"*
(0 cm)
29"
(73.66 cm)
0"*
(0 cm)
0"*
(0 cm)
14" max.
(35.6cm)
27¾"
(70.5 cm)
5½"
(14 cm)
48 in.
(310 cm
)
2
2
24 in.
(155 cm
)
2
2
3"
(7.6 cm)
3"
(7.6 cm)
*Additional spacing recommended
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
For closet installation with a
door, minimum ventilation
openings in the top and bottom
of the door are required.
Louvered doors with equivalent
air openings are acceptable.
Electric Dryer
* Most installations require a
minimum 5
¹⁄₂
" (14 cm)
clearance behind the dryer for
the exhaust vent with elbow.
NOTE:
Side and bottom exhaust installations have a 90
°
turn
inside the dryer. To determine maximum exhaust length, add one
90
°
turn to the chart.
Number of
90
°
turns
or elbows
Type of
vent
Box or
Louvered
hoods
Angled
hoods
0
Rigid
metal
Flexible metal
64 ft (20 m)
36 ft (11 m)
58 ft (17.7 m)
28 ft (8.5 m)
1
Rigid
metal
Flexible metal
54 ft (16.5 m)
31 ft (9.4 m)
48 ft (14.6 m)
23 ft (7 m)
2
Rigid
metal
Flexible metal
44 ft (13.4 m)
27 ft (8.2 m)
38 ft (11.6 m)
19 ft (5.8 m)
3
Rigid
metal
Flexible metal
35 ft (10.7 m)
25 ft (7.6 m)
29 ft (8.8 m)
17 ft (5.2 m)
4
Rigid
metal
Flexible metal
27 ft (8.2 m)
23 ft (7 m)
21 ft (6.4 m)
15 ft (4.6 m)
Select the route that will provide the straightest and most direct path
outdoors.
Plan the installation to use the fewest number of elbows and turns.
Avoid making 90° turns.
Do not use vent runs longer than specified in vent length chart.
Determine the number of elbows you will need.
A. Louvered hood style
B. Box hood style
4"
(10.2 cm)
4"
(10.2 cm)
A
B
4"
(10.2 cm)
2.5"
(6.4 cm)
Recommended hood styles
Angled hood style is
acceptable.
®