Whirlpool WED7500VW Dimension Guide

Whirlpool WED7500VW Manual

Whirlpool WED7500VW manual content summary:

  • Whirlpool WED7500VW | Dimension Guide - Page 1
    or confined area B. Recessed area C. Closet door with vents 3" (7.6 cm) Recessed or closet installation - Stacked with stack kit (Accessory) 12" (30.5 cm) DRYER 3" (7.6 cm) 48 in.2 (310 cm2) 3" (7.6 cm) EXHAUST VENTING Vent material • Use a heavy metal vent. Do not use plastic or metal foil
  • 1

PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
CUSTOM UNDERCOUNTER, RECESSED AREA AND
CLOSET INSTALLATION
EXHAUST VENTING
WED7500V
Electrical:
A four-wire or three-wire, single phase,
120/240-volt, 60 Hz, AC-only, electrical supply (or
120/208-volt electrical supply, if specified on the
serial/rating plate) is required on a separate 30 amp
circuit, fused on both sides of the line. A time-delay
fuse or circuit breaker is recommended.
Exhaust venting:
Exhaust your dryer to the
outside. 4" (10.2 cm) diameter vent is required.
Heavy metal exhaust vent must be used. Do not use
plastic or metal foil vent. Exhaust outlet hood must
be at least 12" (30.5 cm) from the ground or any
object that may be in the path of the exhaust.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only.
For complete details, see Installation
Instructions packed with product.
Specifications subject to change without notice.
Ref. W10189310
04-02-08
33 ¼"
(84.45 cm)
23
³⁄₈
"
(59.37 cm)
39"
(99.1 cm)
23 ¼"
(60.3 cm)
*
Vent material
• Use a heavy metal vent. Do not use plastic or metal foil vent.
• 4" (10.2 cm) heavy metal exhaust vent and clamps must be used.
Rigid metal vent
• For best drying performance, rigid metal
vents are recommended.
• Rigid metal vent is recommended to
avoid crushing and kinking.
Flexible metal vent
• Flexible metal vents are acceptable only if accessible for cleaning.
• Flexible metal vent must be fully extended and supported when the dryer is in its
final location.
• Remove excess flexible metal vent to avoid sagging and kinking that may result
in reduced airflow and poor performance.
• An exhaust hood should cap the vent to keep rodents and insects from entering
the home.
• Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may
be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).
• Do not use an exhaust hood with a magnetic latch.
* Most installations require a
minimum 5-1/2" (14.0 cm)
clearance behind the dryer for
the exhaust vent with elbows.
Electric Dryer
®
A. Side view - closet or confined area
B. Recessed area
C. Closet door with vents
B
A
3"
(7.6cm)
14"
(35.6cm)
18"(45.7cm)
0"
(0 cm)
0"
(0 cm)
48 in.
2
(310 cm
2
)
24 in.
2
(155 cm
2
)
3"
(7.6 cm)
3"
(7.6 cm)
C
1" (2.5 cm)
0"
(0 cm)
0"
(0 cm)
0"
(0 cm)
33
¹⁄₄
" min.
(84.45 cm)
23
³⁄₈
"
(59.37 cm)
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
DRYER
WASHER
(30.5 cm)
12"
0" (0 cm)
0" (0 cm)
A
B
C
1" (2.5 cm)
48 in.
2
(310 cm
2
)
24 in.
2
(155 cm
2
)
3"
(7.6 cm)
3"
(7.6 cm)
3" (7.6 cm)
Custom undercounter installation - Dryer only
Recessed or closet installation - Dryer only
Recessed or closet installation - Stacked with stack kit (Accessory)
4" (10.2 cm) heavy metal exhaust vent
4"
10.2 cm
Exhaust
Recommended hood styles are shown here.
The angled hood style (shown here) is acceptable.
A. Louvered hood style
B. Box hood style
4"
(10.2 cm)
4"
(10.2 cm)
B
A
4"
(10.2 cm)
2½"
(6.4 cm)