Whirlpool WFW9050XW Dimension Guide

Whirlpool WFW9050XW Manual

Whirlpool WFW9050XW manual content summary:

  • Whirlpool WFW9050XW | Dimension Guide - Page 1
    Front-Loading Automatic Washer PRODUCT MODEL NUMBERS WFW9050X Electrical: A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is recommended that a separate circuit serving only this appliance be provided. Drain
  • 1

Front-Loading Automatic Washer
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
WFW9050X
Electrical:
A 120 volt, 60 Hz., AC only, 15- or 20-amp,
fused electrical supply is required. A time-delay fuse
or circuit breaker is recommended. It is recommended
that a separate circuit serving only this appliance
be provided.
Custom undercounter installation-washer only
Washer dimensions
Because Whirlpool Corporation policy includes a continuous commitment to improve
Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specifications without notice.
Instructions packed with product. Specifications subject to change without notice.
Ref. W10307859B
6/2010
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required.
Louvered doors with equivalent air ventilation openings are acceptable.
For cabinet installation, with a door, the minimum ventilation openings in the top are required.
Drain System Options
Standpipe drain system - wall or floor (views A & B)
The standpipe drain requires a minimum diameter
standpipe of 2" (50 mm). The minimum carry-away
capacity can be no less than 17 gal. (64 L) per minute.
The top of the standpipe must be at least 30" (762 mm)
high and no higher than 96" (2.4 m) from the bottom
of the washer.
Laundry tub drain system (view C)
The laundry tub needs a minimum 20 gal. (76 L)
capacity. The top of the laundry tub must be
at least 30" (762 mm) above the floor.
Floor drain system (view D)
The floor drain system requires a siphon break that
may be purchased separately. See “Tools and Parts.”
The siphon break must be a minimum of 28" (710 mm)
from the bottom of the washer. Additional hoses might
be needed.
30
" min.
(762 mm)
A
B
30
" min.
(762 mm)
28
" min.
(710 mm)
C
D
5
0
1
/
4
"
(1276 mm)
27
"
(686 mm)
36
"
(914 mm)
30
1
/
2
"
(775 mm)
27
"
(686 mm)
1
"
(25 mm)
1
"
(25 mm)
2
" (50 mm)
36
" min.
(914 mm)
3
"
(76 mm)
48
"
(1220 mm)
3
"
(76 mm)
48 in.
2
(310 cm
2
)
24 in.
2
(155 cm
2
)
1
"
(25 mm)
4
"
(102 mm)
30
1
/
2
"
(775 mm)
A
B
38
" min.
(965 mm)
1
"
(25 mm)
27
"
(686 mm)
A
B
1
"
(25 mm)
1
"
(25 mm)
4
"
(102 mm)
30
1
/
2
"
(775 mm)
3"
(76 mm)
3"
(76 mm)
48 in.
2
*
(310 cm
2
)
24 in.
2
*
(155 cm
2
)
1
"***
(25 mm)
1
" (25 mm)
27
"
(686 mm)
1
"***
(25 mm)
5
1
/
4
"**
(133 mm)
12
" (305 mm)
72
"
(1829 mm)
1
"
(25 mm)
(178 mm)
7
"
(178 mm)
7
"
(229 mm)
9
"
(102 mm)
4
"
(25 mm)
1
"
(686 mm)
27
"
(800 mm)
31
1
/2
"
A. Side view - closet or confined area
B. Closet door with vents
A. Recessed area
B. Side view - closet or confined area
* Min. top and bottom air openings for closet door.
* External exhaust elbow requires additional space.
*** Wall, door, and floor molding may require additional spacing.