Whirlpool WGD71HEBW Dimension Guide

Whirlpool WGD71HEBW Manual

Whirlpool WGD71HEBW manual content summary:

  • Whirlpool WGD71HEBW | Dimension Guide - Page 1
    closet installation All dimensions show recommended and minimum spacing allowed. ■■ Additional spacing should be considered for ease of installation and servicing. ■■ Additional clearances might be required for wall, door, floor moldings, dryer venting, and gas line. ■■ Additional spacing should be
  • Whirlpool WGD71HEBW | Dimension Guide - Page 2
    to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the will improve venting regardless of length. Because Whirlpool Corporation policy includes a continuous commitment to Installation Instructions packed with product. Specifications subject
  • 1
  • 2

Gas Dryer
PRODUCT MODEL NUMBERS
W10573707B
10/2013
WGD70HEB, WGD71HEB, WGD80HEB, WGD86HEB,
WGD88HEA, WGD94HEA, WGD96HEA, WGD98HEB
27"
(686 mm)
38
3
/
4
" Min.
(984 mm)
39" Max.
(990 mm)
Back view:
6
1
/
4
"
(159 mm)
29
7
/
8
"*
(759 mm)
3
1
/
2
"*
(89 mm)
5
3
/
4
"*
(146 mm)
6
1
/
8
"*
(156 mm)
14
3
/
8
"
(365 mm)
25
3
/
4
"
(654 mm)
3
/
4
"*
(18 mm)
NOTE:
Most installations require a minimum of 5" (127 mm)
clearance behind dryer for exhaust vent with elbow. See “Venting
Requirements.”
Side view:
Front view:
* Approx. measurement
DRYER DIMENSIONS
Gas
* Approx. measurement
Water inlet
(Steam Models Only)
Vent
18" min.
(457 mm)
1"
(25 mm)
5"
(127 mm)
24 in.
2
min.
(155 cm
2
)
48 in.
2
min.
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
1"
(25 mm)
Recommended installation clearances (dryer only):
*
*
0" (0 mm) spacing is allowed.
*
Installation spacing for recessed area
or closet installation
All dimensions show recommended and minimum spacing allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, floor moldings, dryer venting, and gas line.
Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door
are required. Louvered doors with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.