Whirlpool WGD7800XL Dimension Guide

Whirlpool WGD7800XL Manual

Whirlpool WGD7800XL manual content summary:

  • Whirlpool WGD7800XL | Dimension Guide - Page 1
    of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See spacing should be considered for ease of installation and servicing. ■■ Additional clearances might be required for wall, spacing should be considered on all sides of the dryer to reduce noise transfer. ■■ For closet installation,
  • Whirlpool WGD7800XL | Dimension Guide - Page 2
    larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1. ELECTRICAL REQUIREMENTS A 120-volt, 60 Hz, AC-only, 15
  • 1
  • 2

Gas Dryer
PRODUCT MODEL NUMBERS
W10388777
06/2011
WGD7300X, WGD7400X,
WGD7600X, WGD7800X
NOTE:
Most installations require a
minimum of 5" (127 mm) clearance
behind dryer for exhaust vent with
elbow. See “Venting Requirements”.
Dryer with extended back:
Dryer with flat back
:
Back view:
Bottom view:
Recommended Installation Spacing:
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with tested spacing of 0" (0 mm) clearance
on sides and rear.
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door, and floor moldings.
Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the
door are required. Louvered doors with equivalent ventilitation openings are acceptable.
Companion appliance spacing should also be considered.