of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See spacing should be considered for ease of installation and servicing. ■■ Additional clearances might be required for wall, spacing should be considered on all sides of the dryer to reduce noise transfer. ■■ For closet installation, - Whirlpool WGD7800XL | Dimension Guide - Page 2
larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1. ELECTRICAL REQUIREMENTS A 120-volt, 60 Hz, AC-only, 15
Gas Dryer
PRODUCT MODEL NUMBERS
W10388777
06/2011
WGD7300X, WGD7400X,
WGD7600X, WGD7800X
NOTE:
Most installations require a
minimum of 5" (127 mm) clearance
behind dryer for exhaust vent with
elbow. See “Venting Requirements”.
Dryer with extended back:
Dryer with flat back
:
Back view:
Bottom view:
Recommended Installation Spacing:
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with tested spacing of 0" (0 mm) clearance
on sides and rear.
■
Additional spacing should be considered for ease of installation and servicing.
■
Additional clearances might be required for wall, door, and floor moldings.
■
Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
■
For closet installation, with a door, minimum ventilation openings in the top and bottom of the
door are required. Louvered doors with equivalent ventilitation openings are acceptable.
■
Companion appliance spacing should also be considered.