Whirlpool WGD7990XG Dimension Guide
Whirlpool WGD7990XG Manual
View all Whirlpool WGD7990XG manuals
Add to My Manuals
Save this manual to your list of manuals |
Whirlpool WGD7990XG manual content summary:
- Whirlpool WGD7990XG | Dimension Guide - Page 1
spacing for recessed area or closet installation The dimensions shown below are for the recommended spacing for this dryer. ■■ Additional spacing should be considered for ease of installation and servicing. ■■ Additional clearances might be required for wall, door, and floor moldings, and - Whirlpool WGD7990XG | Dimension Guide - Page 2
larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1. ELECTRICAL REQUIREMENTS A 120-volt, 60 Hz, AC-only, 15
Gas Dryer
PRODUCT MODEL NUMBERS
Front view:
Side view:
Back view:
Recommended Installation Spacing:
Installation spacing for recessed area or closet installation
The dimensions shown below are for the recommended spacing for this dryer.
■
Additional spacing should be considered for ease of installation and servicing.
■
Additional clearances might be required for wall, door, and floor moldings, and dryer venting.
■
Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer.
■
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are acceptable.
■
Companion appliance spacing should also be considered.
W10372564
06/2011
WGD7990X
27"
(686 mm)
42
3
/
8
"
(899 mm)
1
/
"
30
7
/
8
"
(783 mm)
54
3
/
8
"
(1381 mm)
23
1
/
2
"
(597 mm)
Door open view:
24 in.
2
(155 cm
2
)
48 in.
2
(310 cm
2
)
1"
(25 mm)
1"
(25 mm)
5"
(102 mm)
3"
(76 mm)
34" recommended
(864 mm)
18" min.
(457 mm)
3"
(76 mm)
NOTE:
Most installations require a minimum 5" (102 mm)
clearance behind the dryer for the exhaust vent with elbow.
See “Venting Requirements”.