Whirlpool WGD87HEDW Dimension Guide

Whirlpool WGD87HEDW Manual

Whirlpool WGD87HEDW manual content summary:

  • Whirlpool WGD87HEDW | Dimension Guide - Page 1
    Gas Dryer PRODUCT MODEL NUMBERS WGD72HED, WGD81HED, WGD8740D, WGD87HED, WGD95HED, WGD97HED Front view: Side view: 27" (686 mm) 383/4" Min. (984 mm) 39" Max. (990 mm) Bottom view: Back view: 61/4" (159 mm) Recommended Installation Spacing: 53/4"* (146 mm) Vent Water inlet (Steam Models
  • Whirlpool WGD87HEDW | Dimension Guide - Page 2
    larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1. ELECTRICAL REQUIREMENTS A 120-volt, 60 Hz, AC-only, 15
  • 1
  • 2

Gas Dryer
PRODUCT MODEL NUMBERS
Front view:
Side view:
Back view:
Recommended Installation Spacing:
W10676163A
04/2014
WGD72HED, WGD81HED, WGD8740D, WGD87HED, WGD95HED, WGD97HED
Bottom view:
27"
(686 mm)
38
3
/
4
" Min.
(984 mm)
39" Max.
(990 mm)
6
1
/
4
"
(159 mm)
29
7
/
8
"*
(759 mm)
3
1
/
2
"*
(89 mm)
5
3
/
4
"*
(146 mm)
6
1
/
8
"*
(156 mm)
14
3
/
8
"
(365 mm)
25
3
/
4
"
(654 mm)
3
/
4
"*
(18 mm)
NOTE:
Most installations require a minimum of 5" (127 mm)
clearance behind dryer for exhaust vent with elbow. See
“Venting Requirements.”
18" min.
(457 mm)
1"
(25 mm)
5"
(127 mm)
24 in.
2
min.
(155 cm
2
)
48 in.
2
min.
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
1"
(25 mm)
Installation spacing for recessed area or closet installation
All dimensions show recommended and minimum spacing allowed.
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door, floor moldings, dryer venting, and gas line.
Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are
required. Louvered doors with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
Gas
Water inlet
(Steam Models Only)
Vent