Issue Description CPR #2005-08-18-SIEM06-01 Initial Folder configuration issues. Poor copy quality for line and normal mode copies Problem Resolution Default fold settings were being reset after power cycle of the controller. Fold settings are now maintained across power cycles. Intermitantly the folder was not properly recognized by the controller resulting in reprinted pages and delays in printing. The folder configuration routine was enhanced to handle additional error cases to properly recognize the folder. Certain halftone images would be distorted when making normal or line mode copies. The copy path for both line and normal mode was enhanced to improve image quality for 100% copies. 9.5 The following Customer issues were resolved in 10.2 b 141 Issue Description Problem Resolution 721 short sheet reprint problem On the 721 at an end-of-roll condition short pages are not always reprinted. We have improved the short sheet detection algorithm for the 721 to properly reprint short or smeared pages. Stamps Disappear when inserted in a set and submitted thru DST. SPAR#62833131 The AccXES controller only looked for the "HPRTLNATIVEMODE" command at the start of a job. This PJL command is now handled on a file by file basis instead of on a job basis. Synergix scanner N5T controller hang up randomly with 5000011 error code. SPAR# 573361022 Invalid data was received from the scanner during scan-to-net mode that caused the AccXES controller to hang. The AccXES controller was modified to process the valid data only. File loses partial blue fine grid lines when submitted thru AccXES. The controller was not processing the complex fine lines correctly. The fine-line handling algorithm was enhanced for this type of document. SPAR# 171975778 Reduced or enlarged files scaled to A2 are not oriented correctly. SPAR# 411076598 The orientation algorithm on for copy documents did not handle scaled documents correctly. The copy mode orientation algorithm was corrected. New text strings displayed as "???" in non-English languages New strings were left out of The new strings were replaced the non-English language files by translated strings. 620mm Roll not supported for 6030 / 6050 printers Support was added for the 620mm roll on 6030/6050 Page 28

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

Issue Description
Problem
Resolution
CPR #2005-08-18-SIEM06-01
Default fold settings were
being reset after power cycle
of the controller.
Fold settings are now
maintained across power
cycles.
Initial Folder configuration
issues.
Intermitantly the folder was
not properly recognized by the
controller resulting in reprinted
pages and delays in printing.
The folder configuration
routine was enhanced to
handle additional error cases
to properly recognize the
folder.
Poor copy quality for line and
normal mode copies
Certain halftone images would
be distorted when making
normal or line mode copies.
The copy path for both line
and normal mode was
enhanced to improve image
quality for 100% copies.
9.5 The following Customer issues were resolved
in 10.2 b 141
Issue Description
Problem
Resolution
721 short sheet reprint
problem
On the 721 at an end-of-roll
condition short pages are not
always reprinted.
We have improved the short
sheet detection algorithm for
the 721 to properly reprint
short or smeared pages.
Stamps Disappear when
inserted in a set and submitted
thru DST.
SPAR#62833131
The AccXES controller only
looked for the
“HPRTLNATIVEMODE”
command at the start of a job.
This PJL command is now
handled on a file by file basis
instead of on a job basis.
Synergix scanner N5T
controller hang up randomly
with 5000011 error code.
SPAR# 573361022
Invalid data was received from
the scanner during scan-to-net
mode that caused the AccXES
controller to hang.
The AccXES controller was
modified to process the valid
data only.
File loses partial blue fine grid
lines when submitted thru
AccXES.
SPAR# 171975778
The controller was not
processing the complex fine
lines correctly.
The fine-line handling
algorithm was enhanced for
this type of document.
Reduced or enlarged files
scaled to A2 are not oriented
correctly.
SPAR# 411076598
The orientation algorithm on
for copy documents did not
handle scaled documents
correctly.
The copy mode orientation
algorithm was corrected.
New text strings displayed as
“???” in non-English
languages
New strings were left out of
the non-English language files
The new strings were replaced
by translated strings.
620mm Roll not supported for
6030 / 6050 printers
Support was added for the
620mm roll on 6030/6050
Page 28