Yamaha QY700 Owner's Manual - Page 271

Source segment, Spot clock, Destination phrase, Event, Argument range

Page 271 highlights

7. Pattern Jobs 2. Source segment • The two boxes to the right of the M select the source segment. 0101 1101 Measure: beat 001:1,...,256:16 3. Spot clock • The Spot Clock value selects the interval of each measure from which data are to be extracted. • The interval is set by clock cycles, where each measure starts at cycle 0000. There are 480 cycles per quarter note. • For example, assume that the meter is set to 4/4. In this case, if you want to extract data only from the first half of each measure, you would set the range to 0000~0959. If you wanted to copy only those events that fall exactly on the fourth beat, you would set the range to 1440~1440. 0000 4/4 0480 0960 1440 1919 0000 0240 0480 0720 0960 1200 1439 6/8 6. Argument range • The lowest two boxes on the screen select the argument range. The QY700 will extract only those events whose argument falls within the specified range. • If you are extracting note events, for example, you can use this setting to limit extraction to all note events within a certain pitch range (for example, C3 to C4). If extracting program-change events, you can limit extraction to events with a certain range of program numbers. • Note that the EXC event type does not accept an argumentrange value. • The values listed below show the maximum ranges. In all cases you can set a smaller range. Note that the first value of the range must be less than or equal to the second value. 0101 1101 C-2,...,G8 -8192,...,+8191 000,...,127 Maximum range for note events. Maximum range for pitchbend events. Maximum range for all event types other than note and pitchbend. 0101 1101 0000,...,3840 4. Destination phrase • The second Phrase value selects the destination phrase (user phrase). 0101 1101 Off, 01,...,99 Off 01,...,99 No destination. (Erase only.) Selects destination phrase. 5. Event • The third pair of boxes (at the center of the screen) selects the event type to be extracted. 0101 1101 Note, PC, PB, CC (000,...,127, All), CAT, PAT, EXC Note Note events (C-2,...,G8, All) PC Program change PB Pitch bend CC(000,...,127,All) Control change (Any single control- change message type 000 to 127, or all control-change messages) CAT Channel aftertouch PAT Polyphonic aftertouch EXC System exclusive 270 Chapter 5. PATTERN MODE

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334

270
Chapter 5. PATTERN MODE
7. Pattern Jobs
2. Source segment
The two boxes to the right of the M select the source seg-
ment.
0101
1101
Measure: beat
001:1,...,256:16
3. Spot clock
The Spot Clock value selects the interval of each measure
from which data are to be extracted.
The interval is set by clock cycles, where each measure starts
at cycle 0000. There are 480 cycles per quarter note.
For example, assume that the meter is set to 4/4. In this
case, if you want to extract data only from the first half of
each measure, you would set the range to 0000~0959. If
you wanted to copy only those events that fall exactly on
the fourth beat, you would set the range to 1440~1440.
0101
1101
0000,...,3840
4. Destination phrase
The second Phrase value selects the destination phrase (user
phrase).
0101
1101
Off, 01,...,99
Off
No destination. (Erase only.)
01,...,99
Selects destination phrase.
5. Event
The third pair of boxes (at the center of the screen) selects
the event type to be extracted.
0101
1101
Note, PC, PB, CC (000,...,127, All), CAT, PAT, EXC
Note
Note events (C-2,...,G8, All)
PC
Program change
PB
Pitch bend
CC(000,...,127,All)
Control change (Any single control-
change message type 000 to 127, or
all control-change messages)
CAT
Channel aftertouch
PAT
Polyphonic aftertouch
EXC
System exclusive
6. Argument range
The lowest two boxes on the screen select the argument
range. The QY700 will extract only those events whose ar-
gument falls within the specified range.
If you are extracting note events, for example, you can use
this setting to limit extraction to all note events within a
certain pitch range (for example, C3 to C4). If extracting
program-change events, you can limit extraction to events
with a certain range of program numbers.
Note that the EXC event type does not accept an argument-
range value.
The values listed below show the maximum ranges. In all
cases you can set a smaller range. Note that the first value
of the range must be less than or equal to the second value.
0101
1101
C-2,...,G8
Maximum range for note events.
-8192,...,+8191
Maximum range for pitchbend events.
000,...,127
Maximum range for all event types
other than note and pitchbend.
0000
0480
0960
1440
1919
4/4
0000
0480
0240
0960
0720
1200
1439
6/8