Yamaha RXV465 Owner's Manual - Page 23

Natural, EQ - av

Page 23 highlights

INTRODUCTION PREPARATION BASIC OPERATION Optimizing the speaker setting for your listening room (YPAO) 4 To select a sound character for adjustment, press nCursor k to select "EQ" and then press nCursor l / h. If this unit does not work when you press nCursor, press lSETUP once and then operate this unit. EQ;;;;;Natural This unit has a parametric equalizer that adjusts the output levels for each frequency range. The equalizer is adjusted to produce a cohesive sound field based on automatically measured speaker characteristics. In "EQ," you can select the following parametric equalizer characteristics suitable for the desired sound characteristics. Natural This adjusts all speakers to achieve natural sound. Select this if sounds in the high frequency range seem too strong when "EQ" is set to "Flat." Flat This adjusts each speaker to obtain the same characteristics. Select this if your speakers have similar qualities. Front This adjusts each speaker to obtain the same characteristics as the front left and right speakers. Select this if your front left and right speakers have significantly better qualities than the other speakers. 5 Press nCursor n to select "Start" and then press nENTER to start the setup procedure. A countdown starts and a measurement starts in 10 seconds. A loud test tone is output during measurement. Notes • During the automatic setup procedure, do not perform any operation on this unit. • Press nCursor k to cancel the automatic setup procedure. Measurement takes about 3 minutes. To obtain precise results, stay where you will not disturb the measurement, such as to the side of or behind the speakers or outside the room. Notes • When "E-xx" (xx indicates the number) appears during Auto Setup, it means that measurement is canceled due to an error. For details, see "When an error message is displayed during measurement" (page 20). • When an error occurs during measurement, "W-xx" (xx indicates the number) appears. For details, see "When a warning message is displayed after measurement" (page 20). 6 Press nENTER to confirm the settings. The speaker characteristics are adjusted according to measurement results. >Set Cancel 7 To cancel the operation, press nCursor l / h to select "Cancel" and press nENTER. When "Disconnect MIC" appears, remove the optimizer microphone. Auto Setup is complete. The optimizer microphone is sensitive to heat. Store it in a cool place and away from direct sunlight after measurement. Do not leave it in a place where it will be subjected to high temperatures such on an AV component. y • If you do not want to apply the measurement results, select "Cancel." • Perform "Auto Setup" again if you change the number or positions of speakers. • If you press nENTER before removing the optimizer microphone, "1 Auto Setup" of "Speaker Setup" in the setup menu (see page 39) is displayed. When measurement is successfully completed, "YPAO Complete" appears on the front panel display. YPAO Complete ADVANCED OPERATION ADDITIONAL INFORMATION APPENDIX English 19 En

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

19
En
Optimizing the speaker setting for your listening room (YPAO)
English
INTRODUCTION
ADDITIONAL
INFORMATION
APPENDIX
PREPARATION
BASIC
OPERATION
ADVANCED
OPERATION
4
To select a sound character for adjustment,
press
n
Cursor
k
to select “EQ” and then
press
n
Cursor
l
/
h
.
If this unit does not work when you press
n
Cursor
,
press
l
SETUP
once and then operate this unit.
This unit has a parametric equalizer that adjusts the
output levels for each frequency range. The equalizer
is adjusted to produce a cohesive sound field based on
automatically measured speaker characteristics.
In “EQ,” you can select the following parametric
equalizer characteristics suitable for the desired
sound characteristics.
Natural
This adjusts all speakers to achieve natural sound.
Select this if sounds in the high frequency range seem
too strong when “EQ” is set to “Flat.”
Flat
This adjusts each speaker to obtain the same
characteristics. Select this if your speakers have
similar qualities.
Front
This adjusts each speaker to obtain the same
characteristics as the front left and right speakers.
Select this if your front left and right speakers have
significantly better qualities than the other speakers.
5
Press
n
Cursor
n
to select “Start” and then
press
n
ENTER
to start the setup procedure.
A countdown starts and a measurement starts in 10
seconds. A loud test tone is output during
measurement.
Notes
During the automatic setup procedure, do not perform any
operation on this unit.
Press
n
Cursor
k
to cancel the automatic setup procedure.
When measurement is successfully completed,
“YPAO Complete” appears on the front panel display.
Notes
When “E-xx” (xx indicates the number) appears during Auto
Setup, it means that measurement is canceled due to an error. For
details, see “When an error message is displayed during
measurement” (page 20).
When an error occurs during measurement, “W-xx” (xx indicates
the number) appears. For details, see “When a warning message is
displayed after measurement” (page 20).
6
Press
n
ENTER
to confirm the settings.
The speaker characteristics are adjusted according to
measurement results.
7
To cancel the operation, press
n
Cursor
l
/
h
to select “Cancel” and press
n
ENTER
.
When “Disconnect MIC” appears, remove the
optimizer microphone. Auto Setup is complete.
y
If you do not want to apply the measurement results, select “Cancel.”
Perform “Auto Setup” again if you change the number or positions of
speakers.
If you press
n
ENTER
before removing the optimizer microphone,
“1 Auto Setup” of “Speaker Setup” in the setup menu (see page 39) is
displayed.
Measurement takes about 3 minutes. To obtain precise
results, stay where you will not disturb the
measurement, such as to the side of or behind the
speakers or outside the room.
EQ
;;;;;
Natural
YPAO±Complete
The optimizer microphone is sensitive to heat. Store it
in a cool place and away from direct sunlight after
measurement. Do not leave it in a place where it will be
subjected to high temperatures such on an AV
component.
±>Set±±Cancel