Acer AC701 AC701 Monitor Service Guide - Page 3
E. Geometric Distortion
![]() |
View all Acer AC701 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
E. GEOMETRIC DISTORTION E-1 Raster Rotation Signal No.1 to 6 | a - b | ≤ 2.0 mm E-2 Pincushion Signal No.1 to 6 Top Bottom Leftside Rightside : d1 ≤ 2.0 mm : b1 ≤ 2.0 mm : a1 ≤ 1.5 mm : c1 ≤ 1.5 mm E-3 Barrel Signal No.1 to 6 Top Bottom Leftside Rightside : d2 ≤ 2.0 mm : b2 ≤ 2.0 mm : a2 ≤ 1.0 mm : c2 ≤ 1.0 mm E-4 Trapezoid Signal No.1 to 6 Top Bottom Leftside Rightside : d ≤ 2.5 mm : b ≤ 2.5 mm : a ≤ 2.5 mm : c ≤ 2.5 mm E-5 . Parallelogram Signal No.1 to 6 a ≤ 0.5 degree E-6 Overall Distortion Signal No.6 only Top Bottom Leftside Rightside : d ≤ 2.5 mm : b ≤ 2.5 mm : a ≤ 2.5 mm : c ≤ 2.5 mm a Bezel a1 a2 b d1 c1 b1 d2 c2 b2 d b a c a a 3 d b c