Acer AL1911 AL1911 Service Guide - Page 36
Mechanical Requirements
View all Acer AL1911 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
8. MECHANICAL REQUIREMENTS 8.1 Vibration and Shock All testing shall be done in each of three mutually perpendicular axes, referenced to the position of the system as it is in front of the user (i.e., front-to back, side-to-side, and top-tobottom). 8.1.1 Non-Operating The unit should suffer minimal visible cosmetic damage or damage that presents a safety hazard, or impairs the setup and operation of the system after testing. Sinusoidal Vibration: 0.75 G zero-to-peak, 10 to 500Hz, 0.5 octave / minute sweep rate. This requires one sweep, 10 to 500 to 10Hz, along each of the three axes. Random Vibration: 0.008 G2/Hz, 10 to 500 Hz, nominal 2 GRMS. The test shall be for one hour for each of the three axes. Half Sine Wave Shock: 120 G peak, half sine pulse, 2 ms pulse duration. Testing shall consist of one shock in each direction in each axis, for a total of 6 shock inputs. Square Wave Shock: 40 G peak acceleration, 160 inches / second velocity change. There shall be one shock in each direction in each axis, for a total of 6 shock inputs. 8.2 Package Drop Specification Listed below are standards of drop heights for monitor product Product Weight height Specs