Acer AL702 AL702 Monitor Service Guide - Page 20

No power

Page 20 highlights

9. No power on 9.1 No power on (I) Check output voltage +5V, +15V is right or not. OK NG It is not power board problem. Check power switch is turn on or not. NG OK Turn switch on. Check power cord ( P801), Signal cable (P302),P802, P803, CN102, CN103 is connected right or not. NG OK Connect it right. Check C805 is about DC 140V-330V or not. NG OK Check F801, D801, P801 and repair them. Check C807 is over 10V or not. NG OK Check R805, R803, I801 and repair them. Check pin 6 of I801 have same pulse or not. NG OK Check peripheral components of I801 and repair them. Check pin 1 of T802 have same pulse or not. NG OK Check Q803, R813, R814, D806 , R812 and repair them. Check peak voltage of R811 triangle pulse is up to 1 volt or not. NG OK Check D804, R807 and repair them. Check D809, D810, C816, C821, T802 have same short circuit, or the output +5V, +15V is over load. OK NG Check feedback circuit around I802, I803 and the other components and repair them. Repair them. Trouble Sh ooting A LC502 Page 11