RF Input Indication of input level : 75 terminate value No. PARAMETER MIN TYP 1 Video Output Level 0.6 0.9 2 Video S/N 40 45 3 Noise limiting --- 38 4 Video amplitude 2 MHz --- 0.0 at discrete 3 MHz --- -0.5 frequencies 4.43 MHz --- -1.0 MAX UNIT 1.2 Vp-p --- dB 45 dbuV -1.5 dB -2.5 dB -4.0 dB NOTE 5 Sound carriers rejection 5.5/6M 42 hz 6.5 40 MHz --- dB --- dB 6 Audio S/N 50 63 7 Frequency Range for PAL 55.25 8 Audio sensitivity --- dB 801.2 MHZ 5 40 dBuV VGA Input Separate Sync: Level: Polarity: Impedance: Low = 0 to 0.8V High = 2.0 to 5 V Positive or Negative 1 k ohm or higher R.G.B. Input Signal: (comply with VESA) Level: 0 to 700mv Positive Rise/Fall time: < 5ns Overshoot: < 10% of maximum transition. Impedance: 75 ± 5% Current Sink and Source When low level is asserted, the maximum current sink from any single monitor sync input node to the driver is 2.0mA. When high level is asserted, the maximum current source from the driver to any single monitor sync input node is 500uA.