Uniformity, Maximum Luminance in 9 Points 1- 9, Minimum Luminance in 9 points 1- 9
View all Acer B223PWL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
14 1.5.3 Contrast ratio is measured by TOPCON SR-3 1.5.4 Definition of Response time measured by Westar TRD-100A The output signals of photo detector are measured when the input signals are changed from "Full Black" to "Full White" (rising time, TrR), and from "Full White" to "Full Black" (falling time, TrF), respectively. The response time is interval between the 10% and 90% (1 frame at 60 Hz) of amplitudes. 1.5.5 Color chromaticity and coordinates (CIE) is measured by TOPCON SR-3. 1.5.6 Central luminance is measured by TOPCON SR-3v. 1.5.7 Luminance uniformity of these 9 points is defined as below and measured by TOPCON SR-3 Uniformity Maximum Luminance in 9 Points (1- 9) Minimum Luminance in 9 points (1- 9) 1.6 Environmental Requirements: Operating Storage Temperature: 0°C - +40°C -20°C - +60°C Humidity: 15% - 90% 15% - 90% Altitude: 12,000 feet (3,658m) 40,000 feet (12,192m)