SOP of firmware upgrade, 1 Operational condition, Operational steps - acm
UPC - 884483195961
View all Acer H243H manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Acer ACM Input Language Reset Resolution H. Freq Info V. Freq Input Type S/N OFF ON OFF VGA DVI HDMI EMEA English Russian Deutsch Français Español Italiano Dutch Finnish NO-EMEA English ᐿʕ˖ Deutsch Français Español Italiano --- --- Notes: (1) Clock default 50 is for Visa timing. Others depend on timing. (2) Depend on timing & S/N Acer -LCD-H243H OFF --- English --(2) 6. SOP of firmware upgrade (Manufacturer of Scaler is Mstar) 6.1 Operational condition: Equipment: PC, ISP card, signal cable and power cable. ESD requirements: antistatic wrists, antistatic gloves (fingers), and connecting cable Name of ISP program: ISP_Tool_v3.7.5.exe Manufacture of FW ICjPMC/SST/MX 6.2 Operational steps: 1. Connection: connect PC to PCBA with signal cable, and then keep AC and DC in open state. 10