Acer X163W X163W LCD Monitor Service Guide - Page 6

Electrical and Optical Characteristics and Performance - specs

Page 6 highlights

Acer 2.3 Electrostatic Discharge Requirements Acer -LCD-X163W Item Condition Spec Contact discharge : 4KV Contact discharge : 8KV ● Electrostatic Discharge IEC61000-4-2(EN55024) Air discharge : 8KV Air discharge : 15KV ● 2.4 Reliability MTBF Items Condition Spec Ú 40,000 Hours CCFL Life time Luminance becomes 50% Ú 40,000 Hours(min) Note1. Display an all WHITE field at mid Brightness and Contrast settings. Note Excluding the LCD, CCFL Note1 3. Electrical and Optical Characteristics and Performance 3.1 Main Power Supply Items AC Input Voltage Range AC Input Current AC Frequency Range Inrush Current Regulator Efficiency Ripple and Noise DC Output Voltage and Current Power consumption Protection Power management Condition Universal input full range 100Vac 240Vac 100Vac 240Vac 100Vac,cold star,25°C 240Vac,cold star,25°C DC output full loading +14.2V output +5V output VCC14.2V(13.5~16.3V) VCC5.2V(4.95~5.45V) without Audio Spec 100~240VAC /50~60Hz 0.8A(max) 0.4A(max) 50Hz - 60Hz 40A (max) 60A(max) ≥75%