service will not be extended if: (1) the product is repaired, modified or altered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the product is defaced or missing. ASUS PROVIDES THIS MANUAL ESC4000 G2 GPU server system 7 15060-09V10000 - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 2
: RS720-X7/ RS8, RS720-E7/RS12, RS720E7/RS12-E) 42" cable extender ** U se these screws (4) when installing LSI® steel CVPM clip directly on ASUS servers. (Supported servers: RS920-E7/ RS8, RS926Q-E7/RS8) If any of the above items is damaged or missing, contact your retailer. Cache Vault - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 3
bundled screws (2). 4. Install the Cache Vault Power Module to the LSI® steel CVPM clip. Standard installation of Cache Vault power module Some specific ASUS server systms have a specific space for installing Cache Valut Power module, allowing you the use of all your system's expansion slots. For - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 4
card is already installed in a server system, uninstall it from the system, and install the Cache Vault Flash Module to the PIKE 2208 card as instructed above. For details, refer to user manual that came with your server system. Cache Vault Accessory Kit - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 5
2208 card, and installing the Cache Vault Power Module on the steel CVPM clip and holder, install these two assemblies to the specific ASUS server systems as instructed below. Installing the kit on RS720-X7/RS8, RS720-E7/RS12, RS720-E7/ RS12-E server systems 1. Locate the two screw holes on the - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 6
place it on a flat, stable surface. Locate the three screws. For more details on how to uninstall the riser card bracket, refer to the user manual that came with your server system. Cache Vault Accessory Kit - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 7
2208 card. PIKE 2208 card For more details on how to uninstall the riser card bracket, refer to the user manual that came with your server system. Installing the kit on ESC4000 G2 GPU server system 1. Align the two screws on the side of the steel CVPM holder installed with the Cache Vault - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 8
bracket. For more details on how to uninstall the riser card bracket, refer to the user manual that came with your server system. 4. Place the bracket into the server system and secure to the system according to the instructions in the server system's user manual. Cache Vault Accessory Kit - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 9
:// support.asus.com 0800-093-456 聯絡。 1 2 目錄 2 安裝 Cache Vault PIKE 3 安裝 Cache Vault CVPM 3 Cache Vault 3 安裝 Cache Vault PIKE 2208 4 Cache Vault 5 安裝至 RS720-X7/RS8、RS720-E7/RS12、RS720-E7/RS12-E 5 安裝至 TS700-X7/PS4、TS700-E7/RS8 5 安裝至 RS920-E7/RS8、RS926-E7/RS8 6 安裝至 ESC4000 G2 - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 10
LSI® MegaRAID® Cache Vault Accessory Kit 組件 Cache Vault 1):Cache Vault 快閃記 Cache Vault (Cache Vault Flash Module 3 顆) (Cache Vault Power Module) (CVFM02) (CVPM02) 24 24"Cable extender) LSI® CVPM 鐵件夾 螺絲(2):LSI® CVPM 鐵件夾 (Steel CVPM clip/holder 3 顆螺 絲、3 華碩 CVPM 螺絲(3 2 顆 - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 11
安裝 Cache Vault PIKE 控制卡 Cache Vault PIKE 2208 Cache Vault 安裝 Cache Vault CVPM 1 CVPM 2. 取出 LSI® CVPM Cache Vault 3. 翻轉 LSI® CVPM 2)。 4 Cache Vault LSI® CVPM Cache Vault Cache Vault 1 3 3 Cache Vault Accessory Kit 11 - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 12
2 Cache Vault 裝入 2U 裝入 5U 安裝 Cache Vault PIKE 2208 控制卡 1. 取出 PIKE 2208 2 Cache Vault 3. 將 Cache Vault PIKE 2208 1 若您的 PIKE 2208 Cache Vault 12 Cache Vault Accessory Kit - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 13
Cache Vault Cache Vault PIKE 2208 Cache Vault 安裝至 RS720-X7/RS8、RS720-E7/RS12、RS720-E7/ RS12-E 伺服器 1 2 Cache Vault 42 3 Cache Vault 4. 接著將 PIKE 2208 安裝至 TS700-X7/PS4、TS700-E7/RS8 伺服器 1 Cache Vault Accessory Kit 13 - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 14
2 Cache Vault 3 3 4 Cache Vault PIKE 2208 Cache Vault Cache Vault 5 安裝至 RS920-E7/RS8、RS926-E7/RS8 伺服器 1 14 Cache Vault Accessory Kit - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 15
2. 取出 LSI® CVPM 4 3 Cache Vault 42 4 Cache Vault 5. 將 PIKE 2208 PIKE 2208 PIKE 2208 安裝至 ESC4000 G2 GPU 伺服器 1 Cache Vault 3 Cache Vault Accessory Kit 15 - Asus ESC4000 FDR G2 | Cache Vault Accessory Kit Quick Start Guide - Page 16
2 3 4 5 PIKE 2208卡上的 Cache Vault 6 PIKE 2208 7 16 Cache Vault Accessory Kit
15060-09V10000
Cache Vault Accessory Kit
Quick Start Guide
First Edition (V1) T7843
November 2012
Copyright © 2012 ASUSTeK COMPUTER INC. All Rights Reserved.
No part of this manual, including the products and software described in it, may be reproduced,
transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any
means, except documentation kept by the purchaser for backup purposes, without the express written
permission of ASUSTeK COMPUTER INC. (“ASUS”).
Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless
such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the
product is defaced or missing.
ASUS PROVIDES THIS MANUAL “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS
OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ASUS, ITS
DIRECTORS, OFFICERS, EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT, SPECIAL,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF PROFITS,
LOSS OF BUSINESS, LOSS OF USE OR DATA, INTERRUPTION OF BUSINESS AND THE LIKE),
EVEN IF ASUS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY
DEFECT OR ERROR IN THIS MANUAL OR PRODUCT.
SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR
INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE,
AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ASUS. ASUS ASSUMES NO
RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR INACCURACIES THAT MAY APPEAR IN THIS
MANUAL, INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT.
Products and corporate names appearing in this manual may or may not be registered trademarks or
copyrights of their respective companies, and are used only for identification or explanation and to the
owners’ benefit, without intent to infringe.
Contents
Package contents
..................................................................................
2
Installing the Cache Vault Kit on the holder and the PIKE card
.......
3
Installing the Cache Vault Power Module on the steel clip and holder
.....
3
Standard installation of Cache Vault power module
.................................
3
Installing the Cache Vault Flash Module on the PIKE 2208 card
.............
4
Installing the Cache Vault Kit on specific ASUS server systems
.....
5
Installing the kit on RS720-X7/RS8, RS720-E7/RS12, RS720-E7/RS12-E
server systems
.........................................................................................
5
Installing the kit on TS700-X7/PS4, TS700-E7/RS8 server systems
.......
5
Installing the kit on RS920-E7/RS8, RS926-E7/RS8 server systems
......
6
Installing the kit on ESC4000 G2 GPU server system
.............................
7