BenQ RM8601K RS232&LAN Command List

BenQ RM8601K Manual

BenQ RM8601K manual content summary:

  • BenQ RM8601K | RS232&LAN Command List - Page 1
    RM5501K/RM6501K/RM7501K/RM8601K RS232/LAN Protocol Installation Guide 1
  • BenQ RM8601K | RS232&LAN Command List - Page 2
    Table of Contents Introduction ...3 Wire arrangement...3 RS232 pin assignment ...3 Communication setting ...4 Command message reference ...4 Connections and communication settings 4 RS232 serial port with a straight cable ...4 RS232 via LAN...5 RS232 via HDBaseT...5 Protocol Command Description 5
  • BenQ RM8601K | RS232&LAN Command List - Page 3
    Introduction This document describes the hardware interface spec and software protocols of RS232 interface communication between Commercial Display and PC or other control unit with RS232 protocol. This set protocol allow users to assign the ID in the command to control the specify ID monitor. The
  • BenQ RM8601K | RS232&LAN Command List - Page 4
    Communication setting Baud rate select: 38400bps (fixed)/ Data bits: 8 bits (fixed) Parity: None (fixed)/ Stop Bits: 1(fixed) Command message reference PC sends to Monitor command packet followed by "CR". Every time PC sends control command to the Monitor, the Monitor shall response as follows: 1.
  • BenQ RM8601K | RS232&LAN Command List - Page 5
    RS232 via LAN RJ45 port on a display PC or laptop LAN cable Find the Wired LAN IP address of the connected display from the OSD menu and make sure the display and the computer are within the same network. IP Procotol Port: 4660 RS232 via HDBaseT HDBaseT compatible device RJ45 port on a display
  • BenQ RM8601K | RS232&LAN Command List - Page 6
    Set-function listing The PC can control the LCD Monitor for specific actions. The Set-Function command allows you to control the LCD monitor behavior in a remote sit through the RS232 port. The Set-Function packet format consists of 11 bytes. Set-function description Item Length TV ID Command Type
  • BenQ RM8601K | RS232&LAN Command List - Page 7
    Hex 0x38 0x30 0x32 0x73 0x24 0x30 0x37 0x36 0x0D Reply (Hex Format) Name Hex Length 0x34 ID 0x30 0x31 Command type 0x2B CR 0x0D Example 2: Set Brightness as 176 for TV-02 and this command is NOT valid. Send (Hex Format) Name Length Command ID type Command Value1 Value2 Value3 CR
  • BenQ RM8601K | RS232&LAN Command List - Page 8
    Hex 0x34 0x30 0x31 0x2B 0x0D Example 4: Set Tint as 75 for TV-03 and this command is NOT valid. Send (Hex Format) Name Length Command ID type Command Value1 Value2 Value3 Hex 0x38 0x30 0x33 0x73 0x27 0x30 0x37 0x35 CR 0x0D Reply (Hex Format) Name Length Hex 0x34 ID 0x30 0x31
  • BenQ RM8601K | RS232&LAN Command List - Page 9
    Aspect Ratio 8 002: HDMI2 021 : HDMI3 022 : HDMI4 101 : android 102 : OPS s 31 Language 8 s 32 Volume 8 200 Volume - s 35 300 Volume + 9 002: HDMI2 021 : HDMI3 022 : HDMI4 101 : android 102 : OPS 000: Default 001: 16:9 002: 4:3 003: Auto 004 : Panorama Mode 005 : Just Scan 006 :
  • BenQ RM8601K | RS232&LAN Command List - Page 10
    Mute 8 s Remote control 8 s Button&IR Control 8 s All Reset 8 s Monitor ID default : 01 (30 31) 36 002: turn (State change) 002: turn (State change) 40 010 : Remote Up 011 : Remote Down 012 : Remote Left 013 : Remote Right 014 : Remote OK 020 : Remote OSD Menu 021 : Remote
  • BenQ RM8601K | RS232&LAN Command List - Page 11
    Name Length Byte count 1 Byte Bytes 1 order ID 2 Byte 2~3 Command type Command Value1 Value2 Value3 CR 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 4 5 6 7 8 9 Reply: (Command Type="r" or "-") If the Command is valid, Command Type ="r" Name Byte count Length ID 1 Byte 2 Byte
  • BenQ RM8601K | RS232&LAN Command List - Page 12
    Hex 0x38 0x30 0x35 0x72 0x62 0x30 0x36 0x37 0x0D Example 3: Get Tint from TV-0007 and this command is valid. The Tint value is 32. Send (Hex Format) Name Length Command ID type Command Value1 Value2 Value3 CR Hex 0x38 0x30 0x37 0x67 0X65 0x30 0x30 0x30 0x0D Reply (Hex Format)
  • BenQ RM8601K | RS232&LAN Command List - Page 13
    Hex 0x34 0x30 0x31 0x2D 0x0D Example 5: Get backlight sensor from TV-0007 and this command is valid. The lux value is 1786 (ASCII code). Send (Hex Format) Name Length ID Command type Command Value1 Value2 Value3 Value4 CR Hex 0x39 0x30 0x37 0x67 0X6F 0x30 0x30 0x30 0x30 0x0D Reply (Hex
  • BenQ RM8601K | RS232&LAN Command List - Page 14
    The value is +075 degree (ASCII code). NOTE: Positive degree is "+"ASCII code and negative degree is "-"ASCII code. Send (Hex Format) Name Length ID Command type Command Value1 Value2 Value3 Value4 CR Hex 0x39 0x30 0x37 0x67 0X71 0x30 0x30 0x30 0x30 0x0D Reply (Hex Format) Name Length ID
  • BenQ RM8601K | RS232&LAN Command List - Page 15
    PC Get-function command to LCD Monitor Get Function Model Info Len ID 20 Cmd Cmd Code Type (Hex) g 20 RS232 Value Range (ASCII Bytes) LAN (1) Input value: Byte1 - Byte2 - Byte3...Byte15 Byte2~Byte11=0x00 Byte1=0x01: Get Customer Name Byte1=0x02: Get Customer Model Name Byte1=0x04: Get Scaler
  • BenQ RM8601K | RS232&LAN Command List - Page 16
    Aspect Ratio 8 Language 8 Network Setting 14 Off g 77 g 78 g E1 000: Default 001: 16:9 002: 4:3 003: Auto 004 : Panorama Mode 005 : Just Scan 006 : 14:9 007 : PC Mode 000: English 001: Français 002: Español 003: 繁中 004: 简中 005: Português 006: German 007: Dutch 008: Polish 009: Russia
  • BenQ RM8601K | RS232&LAN Command List - Page 17
    . Byte2~Byte15 should be hex value format (1) If Byte1=0x00(IP Setup Mode) at Input value, the return value should be Byte1=0x00 Byte2=0x00: Manual 0x01: DHCP Byte3~9 are reserved, should be 0x00. (2) If Byte1=0x01(IP Address) at Input value, the return value should be Ex: IP address=169
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

1
RM5501K/RM6501K/RM7501K/RM8601K
RS232/LAN Protocol
Installation Guide