Campbell Scientific IRGASON Open Path Eddy Covariance System with IRGASON or E
Campbell Scientific IRGASON Manual
View all Campbell Scientific IRGASON manuals
Add to My Manuals
Save this manual to your list of manuals |
Campbell Scientific IRGASON manual content summary:
- Campbell Scientific IRGASON | Open Path Eddy Covariance System with IRGASON or E - Page 1
Open Path Eddy Covariance System With IRGASON or EC150/CSAT3A Quick Deploy Guide March 2014 - Campbell Scientific IRGASON | Open Path Eddy Covariance System with IRGASON or E - Page 2
1. Setup tripod and mount enclosures. EC100 Electronics Datalogger Enclosure - Campbell Scientific IRGASON | Open Path Eddy Covariance System with IRGASON or E - Page 3
2. Ground tripod and enclosures. Grounding Rod Ground Lug - Campbell Scientific IRGASON | Open Path Eddy Covariance System with IRGASON or E - Page 4
3. Setup tripod or mast with CM20X Crossarm. Crossarm‐To‐Pole Bracket CM20X Crossarm - Campbell Scientific IRGASON | Open Path Eddy Covariance System with IRGASON or E - Page 5
4. Mount the IRGASON or EC150/CSAT3A and point into the prevailing wind. IRGASON Mounting Bracket IRGASON Leveling Bubble Leveling Bubble CSAT3A CSAT3A Mounting Bracket OR EC150 CM20X Crossarm IRGASON Boom Adapter CSAT3A Boom Adapter - Campbell Scientific IRGASON | Open Path Eddy Covariance System with IRGASON or E - Page 6
5. Mount the radiation shield and IRGASON or EC150/CSAT3A Temperature Probe. Radiation Shield CM20X Crossarm IRGASON or EC150/CSAT3A Temperature Probe - Campbell Scientific IRGASON | Open Path Eddy Covariance System with IRGASON or E - Page 7
6. Connect gas analyzer, sonic anemometer, and temperature probe cables to EC100 Electronics. Gas Analyzer Cable Temperature Probe Cable Sonic Anemometer Cable - Campbell Scientific IRGASON | Open Path Eddy Covariance System with IRGASON or E - Page 8
7. Connect system wiring and insert CompactFlash (CF) card. Insert CF card Datalogger Enclosure EC100 Power and SDM Cables - Campbell Scientific IRGASON | Open Path Eddy Covariance System with IRGASON or E - Page 9
Power Cable (can connect here or directly to +12 Vdc power supply) SDM Cable Power Cable SDM Cable If datalogger has rechargeable base, connect cable from +17‐28 Vdc or +18 Vac power supply here Otherwise connect cable from +12 Vdc power supply here - Campbell Scientific IRGASON | Open Path Eddy Covariance System with IRGASON or E - Page 10
steps from left to right, top to bottom). Press to activate the display. Press to display the System Control Menu. Campbell Scientific CR3000 Datalogger 01/01/2012, 14:00:08.4 CPU: OPEC_basic_vx_x.cr3 Running. Select "Sonic Azmth". System Control Sonic Azmth :0.00000 Change Press - Campbell Scientific IRGASON | Open Path Eddy Covariance System with IRGASON or E - Page 11
(the angle in degrees between true north and the direction the IRGASON or EC150/CSAT3A points), and press . Modify Value NUM Sonic Azmth Current Value: 0.00000 New Value: 150 Press to exit. Campbell Scientific CR3000 Datalogger 01/01/2012, 14:00:08.4 CPU: OPEC_basic_vx_x.cr3 - Campbell Scientific IRGASON | Open Path Eddy Covariance System with IRGASON or E - Page 12
Please visit www.campbellsci.com to obtain contact information for your local US or International representative.
Open Path Eddy Covariance System
With IRGASON or EC150/CSAT3A
Quick Deploy Guide
March 2014