Canon REALiS LCOS SX50 Realis Command Codes

Canon REALiS LCOS SX50 Manual

Canon REALiS LCOS SX50 manual content summary:

  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 1
    SX50 User Commands 2005.2.2 Communication Specifications Communication Flow Error List Command List Command System Chart Power Management Mode Key Spaces of 0 or more characters, Tab (09h), other separators Spaces of 1 or more characters, Tab (09h), other separators Separators between
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 2
    Contents Item 1. Overview 2. Communication Specifications 3. Communication Flow 4. Command System 5. Control Mode 6. Key/Emulation function 7. Power Management Mode 8. Command List 9. Command Descriptions REMOTE LOCAL POWER INPUT AUTOPC DOTS TRACK HPOS VPOS HPIX VPIX SEL ASPECT IMAGE BRI CONT SHARP
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 3
    1. Overview These specifications describe the methods of controlling the SX50 projector from the PC over an RS-232C connection. Virtually all operations possible with the remote control can be controlled from the PC. The following symbols are used in these specifications. Symbol Description △
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 4
    are considered single-byte characters. No procedure None None Not supported Tc Character interval: 10 ms Tr Command/response interval: 10 of SD, RD, and SG Dedicated cable PPCC-S-XS5Xc5on n接ec続tio形n態status COM PORT SERVICE PORT PC Send data SD Receive data RD Signal ground SG 専D用edケicーaフte゙ルd
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 5
    Commands Request transmissions sent from PC to SX50 Transmission format △ △ Character strings consisting of 0 or more alphanumeric characters One of CR (0Dh), LF (0Ah), CR+LF (0Dh+0Ah), Null (00h) Type Null Type
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 6
    Response Transmissions sent from SX50 to PC in response to commands from PC smission format Character strings consisting of one or more ASCII characters The first two characters are always : The first
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 7
    Cable The connection diagram for the cable connecting the PC and projector is shown below.
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 8
    3.Communication Flow Transmission sent At the sending side (PC), the transmission is sent within character intervals of Tc (character interval timeout). Transmission received At the receiving side (SX50), data able to be received within the character interval of Tc is held, and receiving of a
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 9
    4.Command System The command system for SX50 "User Commands" is shown below. Mode change Switch to Remote mode REMOTE Switch to Local mode LOCAL Setting/Control Display setting Input signal switching Input signal setting INPUT Input signal selection SEL Screen setting ASPECT Auto PC
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 10
    method Main unit keys Operation buttons Remote control keys Emulation Switching Return Standby mode Special mode (Service mode) State indicator State indicator ・Microcomputer startup ・Manual power on/off ・LOCAL command All available All available Available ※1 5 minutes elapsed from no signal
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 11
    6. Key/Emulation function The table below shows how the main unit/remote control keys and Emulation function operate in each control mode. Key/Emulation Remote control Main unit keys Remote control emulation Main unit key emulation Unlock ○ LOCAL mode Remote Main unit key control lock lock
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 12
    7.Power Management Mode During Remote mode, Power Management is not in standby regardless of the SX50 settings. If the SX50 is set to REMOTE mode during standby, it changes to the projection state. Projecting in progress Remote mode POWER OFF Commands Power Off Lamp cooling in progress 70
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 13
    8. Command List Item Command Description 1 REMOTE 2 LOCAL 3 POWER 4 INPUT 5 AUTOPC 6 DOTS 7 TRACK 8 HPOS 9 VPOS 10 HPIX 11 VPIX 12 SEL 13 ASPECT 14 IMAGE 15 BRI 16 CONT 17 SHARP 18 GAMMA 19 DGAMMA 20 PROG 21 WB 22 WBRGB 23 SAT 24 HUE 25 ACADJUST 26 6AXR 27 6AXG 28 6AXB 29 6AXC 30 6AXM 31 6AXY 32
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 14
    ※ This provides command usage examples. ※ Command type Mode Control Setting Reference Parameter types ※ This defines the environments that support the command (power supply Supported command states state, input signal state, control mode). Power Input Mode OFF ON PM D-RGB A-RGB1 A-RGB2 Comp
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 15
    10. Error List Item Code TYPE Error character string Error description Remedy 1 0001 2 0002 3 0003 e BAD_SEQUENCE e INVALID_COMMAND e INVALID_MODE Communication sequence error Command is invalid (undefined). The designated command cannot be executed in this mode. Wait until the response is
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 16
    11. Miscellaneous Use the remote control emulation function (RC command) in Local mode for the following functions. Function No display Freeze screen Digital zoom Presentation timer Spotlight function RC command parameter NOSHOW FREEZE DZOOM_P, DZOOM_M P_TIMER SPOT
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 17
    Reset setting Reference command ● Input source switching A-RGB2 INPUT ● Toggle button recording C1:DRGB C2:ARGB2 V :VIDEO ● ● ARGB manual for input signal setting ● ● Input signal select AUTO SEL ● ● Input signal select PC not selected ------------ ● ● Screen settings
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 18
    Mode switching > REMOTE < i:OK Mode viewing > GET MODE or ?MODE < g:MODE=LOCAL *Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 19
    switching > LOCAL < i:OK Mode viewing > GET MODE or ?MODE < g:MODE=LOCAL *Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 20
    =OFF Obtain settable parameters > RANGE POWER < r:POWER=I,ON,OFF *Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 21
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 22
    use the GET command of the respective parameter. Example > AUTOPC < i:OK *Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 23
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× × ○ ○ × × × × ○ × ※If a state is not supported, "INVALID_MODE", "NOT_POWER_SUPPLIED" or "INVALID_SOURCE" is returned with the Err response. ※If the required signal input is not available, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 24
    Obtain settable parameter range (Min, Max) > RANGE TRACK < r:TRACK=N,0,31 *Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 25
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× × ○ ○ × × × × ○ × ※If a state is not supported, "INVALID_MODE", "NOT_POWER_SUPPLIED" or "INVALID_SOURCE" is returned with the Err response. ※If the required signal input is not available, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 26
    Obtain settable parameter range (Min, Max) > RANGE VPIX < r:VPIS=N,0,1000 *Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 27
    > GET SEL or ?SEL < g:SEL=575p This retrieves the input signal. *Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 28
    the screen size. Obtain settable parameters > RANGE ASPECT < r:ASPECT=I,NORMAL,WIDE,AUTO *Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 29
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 30
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 31
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 32
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 33
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 34
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 35
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× × × × ○ ○ ○ × ○ × ※If a state is not supported, "INVALID_MODE", "NOT_POWER_SUPPLIED" or "INVALID_SOURCE" is returned with the Err response. ※If the required signal input is not available, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 36
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 37
    range (Min, Max) > RANGE WBRGB < r:WBRGB=N,-20,20,-20,20,-20,20 *Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 38
    Obtain settable parameter range (Min, Max) > RANGE SAT < r:SAT=N,-20,20 *Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 39
    Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× × × ○ × - - ○ ○ × - ○ ○ × ※If a state is not supported, "INVALID_MODE", "NOT_POWER_SUPPLIED" or "INVALID_SOURCE" is returned with the Err response. ※If the required signal input is not available, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 40
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 41
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 42
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 43
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 44
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ × ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 45
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 46
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 47
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 48
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 49
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 50
    Command States Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Video S-Video ×○× ○ ○ ○ ○ ○ ○ ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an "i:BUSY" reply may
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 51
    no signals are input. Obtain settable parameters > RANGE NOSIG < r:NOSIG=I,BLACK,BLUE,LOGO ※Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 52
    nothing is displayed. Obtain settable parameters > RANGE NOSHOW < r:NOSHOW=BLACK,BLUE,LOGO ※Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 53
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 54
    r:LANG=I,ENG,FRA,GER,ITA,SPA,POR,SWE,DUT,RUS,CHS,CHT,KOR,JPN ※Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 55
    the terminal setting state. Obtain settable parameters > RANGE TERMINAL < r:TERMINAL=I,IN,OUT ※Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 56
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 57
    Power supply Input OFF ON PM D-RGB A-RGB1 A-RGB2 Comp Mode Video S-Video None Remote Local ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. ※When the power supply state is in the process of switching, an
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 58
    in remote control emulation. ・ USB mouse function ・ Switching function to Special mode (Service mode) Example Setting > RC POWER < i:Ok ※Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 59
    . It simply emulates pressing of the buttons. Example Setting > MAIN MENU < i:OK ※Commands are indicated by ">", and responses are indicated by "
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 60
    Commands GET Function Retrieve data Parameter Parameter Meaning MODE MODE POWER POWER SUPPLY STATE INPUT INPUT STATE INPUT SIGNAL SETTING DOTS TOTAL NUMBER OF DOTS TRACK TRACKING HPOS HORIZONTAL POSITION VPOS VERTICAL POSITION HPIX HORIZONTAL RESOLUTION VPIX VERTICAL RESOLUTION
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 61
    Response Responses are made in the formats below for each parameter. Parameter MODE Response MODE=REMOTE | LOCAL POWER=OFF2ON | ON | ON2OFF | OFF | ON2PMM | PMM | PMM2ON POWER Response State OFF Power off OFF2ON Transitioning from power off→on ON Power on ON2PMM Transitioning from power
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 62
    SIGNALSTATUS LAMPCOUNTER ERR SIGNALSTATUS=NO_SIGNAL | DISPLAYING | SETTING Response NO_SIGNAL DISPLAYING SETTING Meaning Signal not detected Currently displaying video Signal detection and display preparation in progress LAMPCOUNTER= Lamp on time Meaning (Lamp on
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 63
    × ○ × ○ × ○ × ○ × ○ × ○ × ○ × ○ × ○ × ○ × ○ × ○ × ※If a state is not supported, "INVALID_MODE", "NOT_POWER_SUPPLIED" or "INVALID_SOURCE" is returned with the Err response. ※If the required signal input is not available, an 'INVALID_SIGNAL (*****)' or 'NO_SIGNAL' is returned
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 64
    Commands RANGE Function Setting range request Parameter Parameter POWER INPUT DOTS TRACK HPOS VPOS HPIX VPIX ASPECT IMAGE BRI CONT SHARP GAMMA DGAMMA PROG WB WBRGB SAT HUE ACADJUST 6AXR 6AXG 6AXB 6AXC 6AXM 6AXY VKS HKS AVOL MUTE BVOL IMAGEFLIP PMM PJON NOSIG NOSHOW LOGOPOS LANG LAMP TERMINAL
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 65
    Response Responses are made in the formats below for each parameter. =, Type I N ID Number Meaning The definition of varies depending on the type. 1. When the type is I (ID) :=, ,
  • Canon REALiS LCOS SX50 | Realis Command Codes - Page 66
    ○ × LANG ×○× ○ ○ ○ ○ ○ ○ ○ ○ × LAMP ×○× ○ ○ ○ ○ ○ ○ ○ ○ × TERMINAL ○ ○ ○ ○ ○ ○ ○ × KEYLOCK ○ ○ ○ ○ ○ ○ ○ × RCCH ×○× ○ ○ ○ ○ ○ ○ ○ ○ × ※If a state is not supported, "INVALID_MODE", "NOT_POWER_SUPPLIED" or "INVALID_SOURCE" is returned with the Err
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

SX50 User Commands
2005.2.2
Communication Specifications
Communication Flow
Error List
Command List
Command System Chart
Power Management Mode
Key
Spaces of
or more characters, Tab (09h), other separators
Spaces of 1 or more characters, Tab (09h), other separators
Separators between parameters
,|
[ ]
Characters in [ ] can be omitted
|
Equivalent to OR