    Spec Sheet Cisco UCS B200 M2 Blade Server CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV A.1 MARCH 9, 2012
  • Cisco N20-B6625-1 | Specifications - Page 2
    20 STEP 9 CHOOSE SERVICE and SUPPORT LEVEL 21 ORDER OPTIONAL KVM CABLE 25 SUPPLEMENTAL MATERIAL 26 Motherboard 26 DIMM and CPU Layout 26 Memory Population Recommendations 27 TECHNICAL SPECIFICATIONS 29 Dimensions and Weight 29 Power Specifications 29 Cisco UCS B200 M2 Blade Server 2
  • Cisco N20-B6625-1 | Specifications - Page 3
    slot to hold an adapter card, and up to two solid-state disk (SSD) drives or hard disk drives (HDDs). Up to eight half-width blade servers can be accommodated in the Cisco UCS 5108 Blade Server Chassis. Figure 1 Cisco UCS B200 M2 Blade Server Cisco UCS B200 M2 Blade Server 3
  • Cisco N20-B6625-1 | Specifications - Page 4
    front view of the Cisco UCS B200 M2 Blade Server. Figure 2 Chassis Front View 4 5 1 2 3 6 78 9 10 11 1 Asset tag (you can remove this tag and 7 Network link status LED add your own) 2 Blade ejector handle 8 Blade health LED 3 Blade ejector handle captive screw 9 Console
  • Cisco N20-B6625-1 | Specifications - Page 5
    on page 25) Integrated in the Cisco UCS 5100 series chassis Integrated in the Cisco UCS 5100 series chassis The built-in Cisco Integrated Management Controller (CIMC) GUI or CLI interface enables you to monitor the server inventory, health, and system event logs. Cisco UCS B200 M2 Blade Server 5
  • Cisco N20-B6625-1 | Specifications - Page 6
    DRIVES, page 14 ■ STEP 5 CHOOSE A PCIe MEZZANINE CARD, page 15 ■ STEP 6 CHOOSE OPERATING SYSTEM, page 16 ■ STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT, page 19 ■ STEP 8 CHOOSE OPTIONAL VALUE-ADDED SOFTWARE, page 20 ■ STEP 9 CHOOSE SERVICE and SUPPORT LEVEL, page 21 6 Cisco UCS B200 M2 Blade Server
  • Cisco N20-B6625-1 | Specifications - Page 7
    mezzanine The N20-B6625-1-UPG B200 M2 base server: ■ Includes: - KVM cable ■ Does not include: - CPUs - Memory - Disk drives - Mezzanine adapter card NOTE: Use the steps on the following pages to configure the server with the components that you want to include. Cisco UCS B200 M2 Blade Server 7
  • Cisco N20-B6625-1 | Specifications - Page 8
    For example: Selecting lower-speed DIMMs: If you use an X5650 CPU (which can support up to 1333-MHz DIMMs) with 1066-MHz DIMMs, the DIMMs will be clocked at an E5620 (which can support up to 1066-MHz DIMMs), the DIMMS will be clocked at the lower speed of 1066 MHz. 8 Cisco UCS B200 M2 Blade Server
  • Cisco N20-B6625-1 | Specifications - Page 9
    Support (MHz)1 N20-X00001 X5570 2.93 95 8 4 6.4 GT/s N20-X00006 X5550 2.66 95 8 4 6.4 GT/s N20-X00002 E5540 2.53 80 8 4 5.86 GT/s N20-X00003 E5520 2.26 80 8 4 5.86 GT/s N20-X00004 shown in the tables, suboptimal performance will result. Cisco UCS B200 M2 Blade Server 9
  • Cisco N20-B6625-1 | Specifications - Page 10
    : 1, 2, or 4 - Operational voltage: 1.5 or 1.35 V - Registered ■ DDR3 ECC registered DIMMs (RDIMMs), supporting Intel SDDC ■ Memory is organized with three memory channels per CPU, with up to two DIMMs per channel, as shown in Figure 3. B200 M2 Memory Organization 10 Cisco UCS B200 M2 Blade Server
  • Cisco N20-B6625-1 | Specifications - Page 11
    DIMM. Memory mirroring reduces the amount of memory available to the operating system by 50 Memory Mirroring Option N01-MMIRROR Memory mirroring option Voltage Ranks /DIMM 1.35/1.5 V 1 1.35/1.5 V 2 1.35/1.5 V 2 4GB DDR3-1333-MHz UDIMM/PC3-10600/single rank/x4/1.35v Cisco UCS B200 M2 Blade
  • Cisco N20-B6625-1 | Specifications - Page 12
    in Channel B CPU 2: 2 DIMMs in Channel D 2 DIMMs in Channel E Total DIMMs 4 8 ■ Select the memory mirroring option (N01-MMIRROR) as shown in Table 5 on page 11. NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs. 12 Cisco UCS B200 M2 Blade Server
  • Cisco N20-B6625-1 | Specifications - Page 13
    system, for example, you can have two 4-GB and two 8-GB DIMMs. One 4-GB/8-GB DIMM pair would located on Channel A of CPU 1, and one 4-GB/8-GB DIMM pair would be located on Channel B of CPU 1. For more information regarding memory, see DIMM and CPU Layout on page 26. Cisco UCS B200 M2 Blade Server
  • Cisco N20-B6625-1 | Specifications - Page 14
    Mounted SSDs Product ID (PID) PID Description HDDs A03-D146GC2 A03-D300GA2 UCS-HDD300GI2F105 A03-D500GC3 A03-D600GA2 UCS-HDD900GI2F106 A03-D1TBSATA SDDs UCS-SSD100GI1F104 146 GB SAS 15K RPM SFF HDD 300 GB 6 Gb drives. You cannot mix SAS and SATA drive types. 14 Cisco UCS B200 M2 Blade Server
  • Cisco N20-B6625-1 | Specifications - Page 15
    (mandatory) You must select one card. To help ensure that your operating system is compatible with the cards you have selected, please check the Hardware Compatibility List at this URL: http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html Cisco UCS B200 M2 Blade Server 15
  • Cisco N20-B6625-1 | Specifications - Page 16
    of the operating systems listed in Table 8. Table 8 Operating Systems PID Description Required RHEL-SFS-2S-1A RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required RHEL-HA-2S-3A Svcs Reqd RHEL-SFS-2S-3A RHEL Option/Scalable File System/2 Socket/3 Yr Svcs Required RHEL-HA-2S-1A-RS
  • Cisco N20-B6625-1 | Specifications - Page 17
    Systems Support VMware vSphere 5 Enterprise Plus for 1 Processor, 4 Year Support VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year, Support VMware vCenter 5 Standard for 1 Processor, 1 Year, Support R VMware vCenter 5 Standard for 1 Processor, 2 Year, Support R Cisco UCS B200 M2 Blade
  • Cisco N20-B6625-1 | Specifications - Page 18
    Systems (continued) PID Description Product ID (PID) VMW-VC5-ST-3A VMW-VC5-ST-4A VMW-VC5-ST-5A VMware vCenter 5 Standard for 1 Processor, 3 Year, Support R VMware vCenter 5 Standard for 1 Processor, 4 Year, Support R VMware vCenter 5 Standard for 1 Processor, 5 Year, Support R 18 Cisco UCS
  • Cisco N20-B6625-1 | Specifications - Page 19
    CONFIGURING the SERVER STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT Choose the optional operating system media listed in Table 9. Table 9 OS Media Product ID (PID) RHEL-6 SLES-11 Svr 2008 R2 EN (1-8CPU, 25CAL), Media Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media Cisco UCS B200 M2 Blade Server 19
  • Cisco N20-B6625-1 | Specifications - Page 20
    10 Cores, Support Required BMC BladeLogic Advanced Edition, 4 Cores, Support Required BMC BladeLogic Advanced Edition, 6 Cores, Support Required BMC BladeLogic Advanced Edition, 8 Cores, Support Required BMC BladeLogic Advanced Edition, 10 Cores, Support Required 20 Cisco UCS B200 M2 Blade Server
  • Cisco N20-B6625-1 | Specifications - Page 21
    field support engineering for the Cisco Unified Computing System (UCS). The Mission Critical Support Service provides a designated technical account manager (TAM) who acts as a strategic resource to help ensure that the unified computing environment runs at peak efficiency. If a problem arises
  • Cisco N20-B6625-1 | Specifications - Page 22
    Yes UC Support 8X5XNBD UC Support 8X5X4 UC Support 24x7x4 UC Support 24x7x2 UC Support 8X5XNBD UC Support 8X5X4 UC Support 24x7x4 UC Support 24x7x2 Unified Computing Warranty Plus Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco
  • Cisco N20-B6625-1 | Specifications - Page 23
    14. NOTE: Cisco does not offer a certified drive destruction service as part of this service. Table 14 Drive Retention Service Options Service Description Service Program Name Service Level GSP UCS Mission Critical Support Service With Drive Retention UC CRIT DR UCS Support Service With Drive
  • Cisco N20-B6625-1 | Specifications - Page 24
    URL: http://www.cisco.com/en/US/services/ps2961/ps10312/ps10321/Cisco_UC_Warranty_Support_DS.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html 24 Cisco UCS B200 M2 Blade Server
  • Cisco N20-B6625-1 | Specifications - Page 25
    keyboard and mouse. With this cable, you can create a direct connection to the operating system and the BIOS running on the server. The KVM cable ordering information is listed in Table 15. Table monitor) 4 Two-port USB 2.0 connector (for a mouse and keyboard) Cisco UCS B200 M2 Blade Server 25
  • Cisco N20-B6625-1 | Specifications - Page 26
    3 Diagnostic button 4 CPU and heat sink 5 DIMM slots 6 Mezzanine adapter card DIMM and CPU Layout Each CPU controls three memory channels, as follows (refer to Figure 6 on page 27): ■ CPU1: Channels A, B, and C - Bank 1 by the CPU on the left (CPU2). 26 Cisco UCS B200 M2 Blade Server
  • Cisco N20-B6625-1 | Specifications - Page 27
    unless both CPUs are installed. Memory Population Recommendations Table 16 shows the preferred order for installing upgrade DIMMs, and while other configurations may work, if problems arise, moving them to the D2, E1, F1 D1, D2, E1, E2, F1 D1, D2, E1, E2, F1, F2 Cisco UCS B200 M2 Blade Server 27
  • Cisco N20-B6625-1 | Specifications - Page 28
    blade server. Doing so will cause a significant loss of performance. ■ Your selected CPU(s) can have some effect on performance. ■ DIMMs can be run in a 1 DIMM per channel or a two DIMM per channel configuration. Each of these arrangements can provide different behavior. 28 Cisco UCS B200 M2 Blade
  • Cisco N20-B6625-1 | Specifications - Page 29
    The system weight given here is an estimate for a fully configured system and will vary depending on the number of CPUs, memory DIMMs, and other optional items. Power Specifications For configuration-specific power specifications, use the Cisco UCS Power Calculator at: http://www.cisco.com/assets
  • Cisco N20-B6625-1 | Specifications - Page 30
    TECHNICAL SPECIFICATIONS 30 Cisco UCS B200 M2 Blade Server
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

C
ISCO
S
YSTEMS
P
UBLICATION
H
ISTORY
170 W
EST
T
ASMAN
D
R
.
S
AN
J
OSE
, CA, 95134
R
EV
A.1
M
ARCH
9, 2012
WWW
.
CISCO
.
COM
Spec Sheet
Cisco UCS B200 M2
Blade Server