Compaq ProLiant 1850R Hot Plug Disk Drive Removal and Replacement Guidelines f
Compaq ProLiant 1850R Manual
View all Compaq ProLiant 1850R manuals
Add to My Manuals
Save this manual to your list of manuals |
Compaq ProLiant 1850R manual content summary:
- Compaq ProLiant 1850R | Hot Plug Disk Drive Removal and Replacement Guidelines f - Page 1
and replacement of hard drives when using Compaq Smart Array Controllers. Compaq is fully committed to providing the ideal client/server high availability solution for customers. High availability features in Compaq Smart Array Controllers include hot-pluggable hard drives. With hot-pluggable hard - Compaq ProLiant 1850R | Hot Plug Disk Drive Removal and Replacement Guidelines f - Page 2
and Novell Directory Services are trademarks of Novell, Inc. Pentium is a registered trademark of Intel Corporation. Copyright ©1999 Compaq Computer Corporation. All rights reserved. Printed in the U.S.A. Hot-Plug Disk Drive Removal and Replacement Guidelines for Compaq Smart Array Controllers White - Compaq ProLiant 1850R | Hot Plug Disk Drive Removal and Replacement Guidelines f - Page 3
Warranty, system administrators can proactively schedule downtime for maintenance and not interrupt critical business operations that rely on these enterprise servers. In addition, with hot-pluggable drives attached to Compaq Smart Array controllers, customers can remove and replace one or - Compaq ProLiant 1850R | Hot Plug Disk Drive Removal and Replacement Guidelines f - Page 4
should not be hotplugged. For step-by-step instructions on hot-plugging your hard drive, refer to the ProLiant Setup and Installation Guide. • If fault-tolerance is currently being used to recover from errors from other drives in the array (such as media errors or signal-integrity errors), loss - Compaq ProLiant 1850R | Hot Plug Disk Drive Removal and Replacement Guidelines f - Page 5
an array controller. The drive is not configured as part of an array. -Or- If this drive is part of an array, then a powered-on controller is not accessing the drive. -Or- The drive is configured as an online spare. CAUTION: In extreme cases, when the number of errors is greater than the firmware - Compaq ProLiant 1850R | Hot Plug Disk Drive Removal and Replacement Guidelines f - Page 6
on. Also, do not turn on the server before turning on the disk enclosure. If these ordering rules are not followed, the Smart Array Controller may mark these external drives as "failed,"which could result in permanent data loss. Conclusion Compaq provides superior rapid recovery features in its
White Paper
November 1999
11DT-119A-WWEN
Prepared by Storage Products
Division
Compaq Computer Corporation
Contents
Rapid Recovery with Hot-
Plug Drives
.................................
3
Guidelines when hot-
plugging a drive
........................
3
Guidelines when Insight
Manager indicates that a
drive is degraded and should
be replaced
...............................
4
Conclusion
.................................
6
Hot-Plug Disk Drive Removal
and Replacement Guidelines for
Compaq Smart Array
Controllers
Abstract:
The purpose of this paper is to communicate to customers
the guidelines for implementing hot-plug removal and replacement
of hard drives when using Compaq Smart Array Controllers.
Compaq is fully committed to providing the ideal client/server high
availability solution for customers.
High availability features in
Compaq Smart Array Controllers include hot-pluggable hard drives.
With hot-pluggable hard drives, customers can remove and replace
one or several drives within a server while the system is online for
rapid recovery while minimizing interruption of the network.
In order to maximize high availability, Compaq has issued customer
guidelines on extending and implementing the removal and
replacement of hot-pluggable hard drives.