Compaq dc5850 Broadcom NetXtreme Gigabit Ethernet Plus NIC

Compaq dc5850 - Microtower PC Manual

Compaq dc5850 manual content summary:

  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 1
    2 Product Description 2 Feature List 3 USB Cable and Headers 3 Supported Platforms 4 BIOS Requirements 4 Selecting a Management Controller 5 F10 Setup Differences 5 F10 Setup - HP Compaq dc5850 Business PC 5 F10 Setup - HP Compaq dc7900 Business PC 6 Limitations 8 Drivers 8 Manageability
  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 2
    , the Broadcom NetXtreme Gigabit Ethernet Plus also features desktop and mobile Architecture for System Hardware (DASH) support. More details on DASH and manageability in the Manageability white paper located at www.hp.com. Product Description The Broadcom NetXtreme Gigabit Ethernet Plus network
  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 3
    supporting Desktop and mobile Architecture for System Hardware (DASH) or Alert Standard Format (ASF) v2.0 • Centralized Power Management Unit (CPMU) • Serial NVRAM interface with Flash auto-sensing • PCIe CLKREQ support • DASH 1.0 and 1.1 support with additional HP value-add management features USB
  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 4
    USB cable. This feature will be offered on supported systems in a future update. Supported Platforms The Broadcom NetXtreme Gigabit Ethernet Plus is available for the following 2008 platforms: • HP Compaq dc5850 Business PC • HP Compaq dc5800 Business PC • HP Compaq dc7800 Business PC • HP Compaq
  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 5
    dc5850 and 7900, the on-board network adapter is by default the primary management controller. For systems supporting the full management capabilities, the user will have to manually between the HP Compaq dc5850 and 7900 Business PCs. F10 Setup - HP Compaq dc5850 Business PC The current Management
  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 6
    is rebooted, the Management Mode will change to DASH. Figure 3 Management Mode (DASH highlighted) in the HP Compaq dc5850 Business PC F10 Setup - HP Compaq dc7900 Business PC The current Management Controller: F10 Setup > Advanced > Manageability Devices. By default, the embedded Intel Ethernet
  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 7
    Figure 4 Management Controller in the HP Compaq dc7900 Business PC The current Management Mode: F10 Setup > File > System Information. The HP Compaq dc7900 Business PC is an Intel Q45-based system which has an integrated Management Engine (ME) within the GMCH for management control. The ME firmware
  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 8
    highlighted) in the HP Compaq dc7900 Business PC Limitations The Broadcom NetXtreme Gigabit Ethernet Plus functions very similarly between a dc7900 and a dc5850. However, there is one important difference iregarding remote wake and Power-On Password behavior. A remote shutdown into a sleep state, S3
  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 9
    Manageability features such as DASH and ASF are disabled by default on the Broadcom NetXtreme Gigabit Ethernet following steps will enable DASH with BMCC: 1. Download the Broadcom NetXtreme Gigabit Drivers for Multiple Operating Systems Softpaq from www.hp.com. 2. Install the Softpaq. 3. Open
  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 10
    Figure 6 Broadcom NetXtreme Gigabit Ethernet Plus network adapter - Information tab 3. Go to the Configuration tab. 4. Expand the OOB Management list to determine if DASH is enabled or disabled. By default DASH is disabled. Figure 7 OOB Management list 5. Enable DASH and click the Apply button. 10
  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 11
    7) Set SNMP Connectivity Name. In addition, make sure the Secure RMCP Support for ASF 2.0 is enabled. Setting Up Initial Administrator Account for DASH use of the Broadcom NetXtreme Gigabit Drivers for Multiple Operating Systems Softpaq. This is available at www.hp.com. Execute the Softpaq, and
  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 12
    Figure 9 Management Firmware Configuration options 3. Enter U for User Account Management. 4. Enter 2 for User Accounts. 5. Enter 1 for Administrator Account. Figure 10 Management options 6. Enter 2 to change Offline from True to False. 12
  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 13
    7. Enter 4=xxx where xxx is the password to set a password. The password by default is blank. Figure 11 Management options 8. Enter 0 twice to get back to the main page. 9. Enter Q to Save and Exit. Figure 12 Save
  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 14
    the Administrator account has been enabled and a password is set with bmcc.exe. The WebGUI is accessible from the following web browsers: • Microsoft includes: • Hardware inventory for processor and memory • Remote system power on, power off, or reset • Determining network settings • Setting up
  • Compaq dc5850 | Broadcom NetXtreme Gigabit Ethernet Plus NIC - Page 15
    was set with bmcc. The password is blank by default, but can be changed during DASH account setup with bmcc. © 2008 Hewlett-Packard Development Company, L.P. The information in this document is subject to change without notice. The only warranties for HP products and services are set forth in the
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

1
Broadcom NetXtreme Gigabit Ethernet Plus NIC
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Feature List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
USB Cable and Headers
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Supported Platforms
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
BIOS Requirements
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Selecting a Management Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
F10 Setup Differences
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
F10 Setup - HP Compaq dc5850 Business PC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
F10 Setup - HP Compaq dc7900 Business PC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Limitations
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Manageability Feature Enabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
DASH Enabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
ASF Enabling
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Setting Up Initial Administrator Account for DASH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
WebGUI
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Connecting with the WebGUI:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14