Dacor DYF42SB Planning Guide
Dacor DYF42SB Manual
View all Dacor DYF42SB manuals
Add to My Manuals
Save this manual to your list of manuals |
Dacor DYF42SB manual content summary:
- Dacor DYF42SB | Planning Guide - Page 1
-019 DYF42SBIWS Discovery® 42" Wide, Built-In Refrigerator with Dispenser Revised 01/31/17 Page 1/4 PLANNING GUIDE WARNING • Observe governing codes and ordinances. Contact your local building department for details as needed. • Install this refrigerator per the directions in this document. Water - Dacor DYF42SB | Planning Guide - Page 2
be easily accessible for service/emergencies. • The water line connects the house's cold-water line with the refrigerator's water-line connector. (The line should be long enough to reach the front of the refrigerator.) • Dacor recommends placing a mat under the refrigerator during preparation to - Dacor DYF42SB | Planning Guide - Page 3
DYF42SBIWS Discovery® 42" Wide, Built-In Refrigerator with Dispenser Revised 01/31/17 Page 3/4 PLANNING GUIDE WARNING • Observe governing codes and ordinances. Contact your local building department for details as needed. • Install this refrigerator notice. www.dacor.com Ph. 800.793.0093 11.15 - Dacor DYF42SB | Planning Guide - Page 4
Document # PG11-019 DYF42SBIWS Discovery® 42" Wide, Built-In Refrigerator with Dispenser Revised 01/31/17 Page 4/4 PLANNING GUIDE HEIGHT AND DEPTH MEASUREMENTS Callout Measured .0 57.2 33.7 122.9 125.4 All specifications subject to change without notice. www.dacor.com Ph. 800.793.0093 11.16
All specifications subject to change without notice.
www.dacor.com
Ph. 800.793.0093
PLANNING
GUIDE
11.13
Water-Supply Requirements
• To function properly, the water dispenser and icemaker
need a cold-water pressure of 30 – 120 psi (207 – 827
kPa). A licensed plumber can answer questions about
water pressure.
• Install a shut-off valve between the refrigerator and water
supply. Use 1/4” copper tubing with compression nut and
sleeve. After connecting the tubing, check for leaks.
• Do not use a piecing type or 3/16” (5 mm) saddle valve
which will reduce water flow and clog more easily.
• The plumbing for the water line can come through the floor
flush with or from the back wall. The preferred location is
in a cabinet beside the refrigerator, preferably on the right.
Reverse-Osmosis Water System
Discovery
®
42” Wide, Built-In
Refrigerator with Dispenser
Document # PG11-019
Revised 01/31/17
Page 1/4
WARNING
• Observe governing codes and ordinances. Contact your local
building department for details as needed.
• Install this refrigerator per the directions in this document.
Electrical Requirements
• You must be able to plug the refrigerator power cord
directly into a grounded, non-GFCI electrical outlet. (Do
not use an extension cord, power strip, or 2-prong adaptor
to connect the refrigerator to its power source.)
• Do not use an outlet that can be turned off by a switch.
• A 115 V, 60 Hz AC only 15- or 20-Amp fused, grounded
electrical supply is required. Dacor recommends connect-
ing the refrigerator to its own dedicated circuit.
• The circuit must be protected by an proper-size fuse or a
circuit breaker.
Location Requirements
The refrigerator is designed for flush installation in a recess
between cabinets.
• The refrigerator should be at least 12” (30 cm) from heat
sources (e.g., ranges, cooktops, ovens, heaters) and away
from direct sunlight/humidity.
• Leave at least 1/2” (1.3 cm) of ventilation space around
the refrigerator.
• Do not install the refrigerator on a rug, carpeting, or any
kind of matting.
• Ensure the floor under the refrigerator is flat, level, and
strong enough to support 600 lbs (272 kg) without sag-
ging; do not install the refrigerator on a raised platform or
sub-flooring.
• Do not install the refrigerator in any kind of space where
the ambient temperature would be less than 50°F (10ºC).
IMPORTANT–Reverse Osmosis
• Water pressure
from
the household cold-water supply
to
a
reverse-osmosis system must be 40–60 psi (276–414 kPa).
• Pressure
from
a reverse-osmosis system
to
the refrigerator
inlet valve must be 30–120 psi (207–827 kPa).
DYF42SBIWS
IMPORTANT
Install copper tubing only in geographic regions where interior
temperatures remain above freezing (32°F/0°C).