    -019 DYF42SBIWS Discovery® 42" Wide, Built-In Refrigerator with Dispenser Revised 01/31/17 Page 1/4 PLANNING GUIDE WARNING • Observe governing codes and ordinances. Contact your local building department for details as needed. • Install this refrigerator per the directions in this document. Water
  • Dacor DYF42SB | Planning Guide - Page 2
    be easily accessible for service/emergencies. • The water line connects the house's cold-water line with the refrigerator's water-line connector. (The line should be long enough to reach the front of the refrigerator.) • Dacor recommends placing a mat under the refrigerator during preparation to
  • Dacor DYF42SB | Planning Guide - Page 3
    DYF42SBIWS Discovery® 42" Wide, Built-In Refrigerator with Dispenser Revised 01/31/17 Page 3/4 PLANNING GUIDE WARNING • Observe governing codes and ordinances. Contact your local building department for details as needed. • Install this refrigerator notice. www.dacor.com Ph. 800.793.0093 11.15
  • Dacor DYF42SB | Planning Guide - Page 4
    Document # PG11-019 DYF42SBIWS Discovery® 42" Wide, Built-In Refrigerator with Dispenser Revised 01/31/17 Page 4/4 PLANNING GUIDE HEIGHT AND DEPTH MEASUREMENTS Callout Measured .0 57.2 33.7 122.9 125.4 All specifications subject to change without notice. www.dacor.com Ph. 800.793.0093 11.16
  • 1
  • 2
  • 3
  • 4

All specifications subject to change without notice.
www.dacor.com
Ph. 800.793.0093
PLANNING
GUIDE
11.13
Water-Supply Requirements
• To function properly, the water dispenser and icemaker
need a cold-water pressure of 30 – 120 psi (207 – 827
kPa). A licensed plumber can answer questions about
water pressure.
• Install a shut-off valve between the refrigerator and water
supply. Use 1/4” copper tubing with compression nut and
sleeve. After connecting the tubing, check for leaks.
• Do not use a piecing type or 3/16” (5 mm) saddle valve
which will reduce water flow and clog more easily.
• The plumbing for the water line can come through the floor
flush with or from the back wall. The preferred location is
in a cabinet beside the refrigerator, preferably on the right.
Reverse-Osmosis Water System
Discovery
®
42” Wide, Built-In
Refrigerator with Dispenser
Document # PG11-019
Revised 01/31/17
Page 1/4
WARNING
• Observe governing codes and ordinances. Contact your local
building department for details as needed.
• Install this refrigerator per the directions in this document.
Electrical Requirements
• You must be able to plug the refrigerator power cord
directly into a grounded, non-GFCI electrical outlet. (Do
not use an extension cord, power strip, or 2-prong adaptor
to connect the refrigerator to its power source.)
• Do not use an outlet that can be turned off by a switch.
• A 115 V, 60 Hz AC only 15- or 20-Amp fused, grounded
electrical supply is required. Dacor recommends connect-
ing the refrigerator to its own dedicated circuit.
• The circuit must be protected by an proper-size fuse or a
circuit breaker.
Location Requirements
The refrigerator is designed for flush installation in a recess
between cabinets.
• The refrigerator should be at least 12” (30 cm) from heat
sources (e.g., ranges, cooktops, ovens, heaters) and away
from direct sunlight/humidity.
• Leave at least 1/2” (1.3 cm) of ventilation space around
the refrigerator.
• Do not install the refrigerator on a rug, carpeting, or any
kind of matting.
• Ensure the floor under the refrigerator is flat, level, and
strong enough to support 600 lbs (272 kg) without sag-
ging; do not install the refrigerator on a raised platform or
sub-flooring.
• Do not install the refrigerator in any kind of space where
the ambient temperature would be less than 50°F (10ºC).
IMPORTANT–Reverse Osmosis
• Water pressure
from
the household cold-water supply
to
a
reverse-osmosis system must be 40–60 psi (276–414 kPa).
• Pressure
from
a reverse-osmosis system
to
the refrigerator
inlet valve must be 30–120 psi (207–827 kPa).
DYF42SBIWS
IMPORTANT
Install copper tubing only in geographic regions where interior
temperatures remain above freezing (32°F/0°C).