    Installation Instructions Integrated Ventilation System For use with models: IVS1, IVSR1, IVS2, IVSR2 Part No. 65278 Rev. H
  • Dacor IVS1 | Installation Instructions - Page 2
    Need Help... If you have questions or problems with installation, contact your Dacor ® dealer or the Dacor Customer Service Team. For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line. Whenever you call, have the model and serial number of the appliance ready. The
  • Dacor IVS1 | Installation Instructions - Page 3
    instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. • Always contact the Dacor Customer Service Team about problems burners, ovens and range hoods. Do not store
  • Dacor IVS1 | Installation Instructions - Page 4
    the filter(s) and all grease-laden surfaces often to prevent grease fires and maintain performance. • If the cooktop and range hood are near a window, use an appropriate window treatment. Avoid long drapes or other window coverings that could blow over the cooktop and ventilation system, resulting
  • Dacor IVS1 | Installation Instructions - Page 5
    pressure The Dacor Integrated Ventilation System (IVS) is designed for installation inside custom hood canopies. Proper installation of the IVS requires proper selection of the custom canopy materials and proper construction. Carefully and closely follow all instructions and warnings concerning
  • Dacor IVS1 | Installation Instructions - Page 6
    models IVSR1 and IVSR2, DO NOT install more than one external blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw by the hood. Install only the in-line or remote blower models specified in these instructions. Duct System
  • Dacor IVS1 | Installation Instructions - Page 7
    Use sheet metal screws as required to support the duct weight. • Do not use flexible metal duct. • Do not use duct work that is smaller in cross-sectional area than 8-inch round duct. Additional Requirements for Models IVSR1 and IVSR2: Models IVSR1 and IVSR2 are not equipped with an internal blower
  • Dacor IVS1 | Installation Instructions - Page 8
    on the top of the IVS from opening. 1. Models IVSR1 and IVSR2 only: Install the remote or in-line blower (see page 5 for specifications) according to the blower installation instructions. 2. Install the duct work starting from the hood working toward the outside vent. Observe the specifications on
  • Dacor IVS1 | Installation Instructions - Page 9
    screws and wrapped with duct tape? See page 6. ‰‰ Is the range hood wired and grounded according to these instructions and in accordance with all applicable electric codes? See pages 4 and 6. ‰‰ Are the filters properly installed according to the use and care manual? ‰‰ Has proper operation been
  • Dacor IVS1 | Installation Instructions - Page 10
    Wiring Diagrams GROUND NEUTRAL LINE WH BLK LAMP DIMMER BLK BLK HALOGEN LIGHTS (2) WH BLK FAN MOTOR M WH FAN SWITCH IVS1, IVSR1 GROUND NEUTRAL LINE WH BLK LAMP DIMMER WH BLK BLK BLK HALOGEN LIGHTS (3) WH BLK FAN MOTORS M M IVS2, IVSR2 FAN SWITCH 8
  • Dacor IVS1 | Installation Instructions - Page 11
  • Dacor IVS1 | Installation Instructions - Page 12
    Dacor ● 600 Anton Blvd. Suite 1000 Costa Mesa, CA 92626 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.Dacor.com