Dacor RV46 Installation Guide

Dacor RV46 Manual

Dacor RV46 manual content summary:

  • Dacor RV46 | Installation Guide - Page 1
    Downdraft Raised Vent Models: RV30, RV36, RV46 Instructions Includes installation instructions for optional cabinet blower (Dacor model CABP3) Part No. 85515 Rev. H Use these downdraft raised vents only with approved Dacor ® cooktops. See the installation instructions for the particular cooktop
  • Dacor RV46 | Installation Guide - Page 2
    supply requirements. Dacor Customer Service RV30 = 30-inch wide raised vent RV36 = 36-inch wide raised vent RV46 = 46-inch wide raised vent Phone: (800) 793-0093 (U.S.A. and Canada) Monday - Friday 6:00 A.M.to 5:00 P.M.Pacific Time Web site: www.Dacor.com Dacor Distinctive Service (repairs under
  • Dacor RV46 | Installation Guide - Page 3
    and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. • Always contact the Dacor Customer Service Team about problems and conditions that you
  • Dacor RV46 | Installation Guide - Page 4
    Contact the Dacor Customer Service Team for examination, repair or adjustment. • Do not leave children or pets alone or unattended in the area around the cooktop when it is in use. Never allow children to sit or stand on an appliance. Do not let children play with the cooktop or the raised vent. Do
  • Dacor RV46 | Installation Guide - Page 5
    " (864 mm) 4 5/811(117 mm) ] _ 97/8 (251mm) with CABP3 1 blower installed A Ib i B Product data label / / / Adjustable .... anchor legs Front View Model Number RV30 RV36 RV46 A - Top Cap Width 30" (762 mm) 36" (914 mm) 46" (1168 mm) B - Chassis Width 27 3/8" (695 mm) 33 3/8" (848 mm) 43
  • Dacor RV46 | Installation Guide - Page 6
    a fire or safety hazard. • Install the raised vent, blower and cooktop so that they can be removed if service is required. • Refer to the cooktop installation instructions for the minimum cutout dimensions specific to the particular raised vent model being installed. The raised vent is equipped with
  • Dacor RV46 | Installation Guide - Page 7
    cooktop, the vent system and the electrical and gas supplies for the cooktop and vent must be provided for inspection and service, Any drawers or shelves placed below the cooktop and in front of the vent must be easy to remove for access to the cooktop, vent and utilities, • For installation with
  • Dacor RV46 | Installation Guide - Page 8
    General System Layout (Continued) / Cooktop Cabinet back Raised vent Raised vent configured for bottom exhaust Wiring, from raised vent to in-line blower 3 1/4" X 10" to round transition / Duct work Outside wall Floor Wall cap on outside wall Duct work ILHSF series in-line blower
  • Dacor RV46 | Installation Guide - Page 9
    raised vent. You must install one of the Dacor blower models listed below for proper operation. For ILHSF or REMP series blowers, see the blower installation instructions. For model CABP3, see the instructions later in this manual sheet metal screws as required to support the duct weight. • To
  • Dacor RV46 | Installation Guide - Page 10
    Raised vent_C L center line I 11 5/8" :oX, ou oo .... kI cooktop I Front Exhaust Dimensions CABP3 Blower - Right Exhaust Countertop -,,, Raised vent ucXt 10 Front Exhaust Dimensions CABP3 Blower- Left Exhaust Model RV30 RV36 RV46 A B 2" (51 mm) 6" (152 mm) 5" (127 mm) 9" (229 mm) C 12"
  • Dacor RV46 | Installation Guide - Page 11
    as short as possible and never exceed the maximums stated at the right. The maximum straight duct length for the raised vent system depends on the model of blower used with the vent system and the number of elbows and transitions used. The Equivalent Number of Feet for each elbow and transition (see
  • Dacor RV46 | Installation Guide - Page 12
    Reinstall the top retainer bracket over the top of the vent cover flange. Secure it in place with the three (3) wing nuts removed in step 4. raisedv_n _ Adj_strlb_JeJsJ_" I Top retainer bracket Installation Preparation for Raised Vent with ILHSFor REMP Series Blower: NOTE: For units using the
  • Dacor RV46 | Installation Guide - Page 13
    NOTE: The raised vent installs in the back of the cutout, separate from the cooktop. It is installed prior to final installation of the cooktop. Installing the Raised Vent 1. Cut a hole in the cabinet to allow the duct work to pass through to the floor or wall for the planned duct system layout. Use
  • Dacor RV46 | Installation Guide - Page 14
    the electrical access panel on the raised vent. 7. Connect the blower power supply wiring from the raised vent to the blower: On installations using a ILHSF or REMP series blower, connect the wiring according to the blower installation instructions. On installations using an cabinet blower, (CABP3
  • Dacor RV46 | Installation Guide - Page 15
    wires/conduit according to remote or in-line blower installation instructions REMP series blower shown Power supply wiring from raised vent to CABP3 blower Electrical Wiring - Cabinet Blower Installations (CABP3) Raised vent electrical connections - see Wiring Diagram B \ Junction box Black
  • Dacor RV46 | Installation Guide - Page 16
    installation instructions. Set the cooktop into the countertop opening so that the back edge of the cooktop overlaps the leading edge of the vent. Verifying Proper Operation WARNING ' Read the raised Vent use and care manual complete- / before operation. ; Make sure the filters are installed
  • Dacor RV46 | Installation Guide - Page 17
    RV Raised Vent Wiring Diagram LOWER LIMIT SWITCH UPPER LIMIT SWITCH TO PUSH BUTTON CIRCUIT Rating: 4 Amps. @ 120 Vac, 60 Hz. For ILHSF or REMP series blower ratings, see the blower installation instructions. 5.0 O 4.0 @ ¢- 0 t'-- 3.0 I 2.0 m o 1.0 O9 0 CABP3 Blower Performance 1O0 200
  • Dacor RV46 | Installation Guide - Page 18
    16 c_mcar
  • Dacor RV46 | Installation Guide - Page 19
    ® The Life of the Kitchen? Dacor • 600 Anton Blvd. Suite 1000 Costa Mesa, CA 92626 • Phone: (800) 793-0093 • Fax: (626)403-3130 Family Owned American Made • www.Dacor.com
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

Installation
Instructions
Downdraft
Raised
Vent
Models:
RV30,
RV36,
RV46
Includes
installation
instructions
for
optional
cabinet blower
(Dacor
model CABP3)
Use these downdraft
raised
vents only with
approved
Dacor ® cooktops.
See the installation
instructions
for
the particular
cooktop
model
being
installed
to determine
suitability.
Part No. 85515
Rev.
H