53-1002749-01 ® 14 December 2012 Fabric OS Message Reference Supporting Fabric OS v7.1.0 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 2
trademarks of their respective owners. Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 3
Fabric OS System Error Message 53-1000046-02 Minor updates to a few messages. Reference Manual June 2006 Fabric OS Message Reference 53-1000242-01 Updated for Fabric OS v5.2.0: -Changed doc title and number -Added the following new modules: IBPD, ICPD, ISCSI, ISNSCD. Added Audit messages: AUTH - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 4
HAM,,HAMK, HIL, IPS, ISNS, L2SYS, MFIC, PDM, PLAT, PORT, RCS, RPCD, RTWR, SEC, SNMP, SWCH, TRCE, TRCK, WEBD, ZONE. -Added new messages to AG, AN, AUTH, Updated Introductory chapters. July 2009 53-1001338-02 Updated for Fabric OS v6.3.0 patch: -Modified a message to BL. -Added new messages to AG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 5
Updated for Fabric OS v7.0.0: -Added new chapters: C3, CAL, MCAST_SS, RTE, and VS. -Added new messages: AG Updated Introductory chapter. December 2011 53-1002749-01 Updated for Fabric OS v7.1.0: - Added new chapters: MM and VDR. - Added new messages: AG , IPS, KTRC, L2SS, LFM, PMGR, PS, RCS, - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 6
- Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 7
xiii Supported hardware and software xiii What's new in this document xv Document conventions xvii Text formatting xvii Command syntax conventions xvii Command examples xviii Notes, cautions, and warnings xviii Key terms xix Notice to the reader xix Additional information xix Brocade - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 8
Configuring system messages and attributes 15 Configuring event auditing 15 Disabling a RASLog message or module 16 Enabling a RASLog message or module 17 Setting the problem 26 Support 27 System module descriptions 28 Log Messages Audit Messages FFDC Messages Fabric OS System Messages AG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 9
Fabric OS Message Reference 53-1002749-01 AUTH Messages 144 BKSW Messages 162 BL Messages 163 BLS Messages 180 BM Messages 182 C2 Messages 187 C3 Messages 194 CAL Messages 202 CCFG Messages 203 CDR Messages 207 CHS Messages 214 CNM Messages 216 CONF Messages 239 CTAP Messages 244 CVLC - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 10
HAMK Messages 546 HIL Messages 548 HLO Messages 565 HMON Messages 567 HSL Messages 568 HTTP Messages 571 IBD Messages 572 IPAD Messages 573 IPS Messages 575 ISNS Messages 578 KAC Messages 582 KSWD Messages 587 KTRC Messages 588 L2SS Messages 590 L3SS Messages 593 LACP Messages 594 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 11
PORT Messages 657 PS Messages 660 PSWP Messages 664 RAS Messages 667 RCS Messages 672 RKD Messages 677 RMON Messages 679 RPCD Messages 680 RTE Messages 683 RTWR Messages 684 SCN Messages 686 SEC Messages 688 SFLO Messages 771 SNMP Messages 774 SPC Messages 777 SPM Messages 790 SS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 12
xii Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 13
procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 14
• Brocade 5460 • Brocade 5470 • Brocade 5480 • Brocade 6505 • Brocade 6510 • Brocade 6520 • Brocade 7800 • Brocade 8000 • Brocade Encryption Switch • Brocade DCX Backbone and Brocade DCX-4S Backbone - FC8-16 port blade - FC8-32 port blade - FC8-48 port blade - FC8-64 port blade - FCOE10-24 DCX Blade - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 15
The following changes have been made since this document was last released: • The lookup lists in Chapter 2 through Chapter 4 provide hyperlinks to messages by type (LOG, Audit, and FFDC). • Information that was added: - AG Messages - ANV Messages - BL Messages - C2 Messages - C3 Messages - CDR - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 16
- FCOE Messages - FCPD Messages - FCR Messages - FICU Messages - FSPF Messages - FSS Messages - HIL Messages - HSL Messages - HTTP Messages - IPS Messages - KAC Messages - KTRC Messages - L2SS Messages - LFM Messages - PMGR Messages - PS Messages - RCS Messages - RTWR Messages - SEC Messages - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 17
new features and documentation updates for this release, refer to the release notes. Document conventions This section addresses Identifies document titles code text Identifies CLI output Identifies command syntax examples For readability, command names in the narrative portions of this guide - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 18
Command examples This book describes how to perform configuration tasks using the Fabric OS command line interface, but does not describe the commands Command Reference. Notes, cautions, and warnings The following notices and statements are used in this manual to hardware, firmware, software, or - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 19
no cost for a user ID and password. White papers, online demonstrations, and data sheets are available through the Brocade website at: http://www.brocade.com/products-solutions/products/index.page For additional Brocade documentation, visit the Brocade website: http://www.brocade.com Release notes - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 20
Error numbers and messages received • supportSave command output • Detailed description of the problem, including the switch or fabric behavior immediately following the problem, and specific questions • Description of any troubleshooting steps already performed and the results • Serial console and - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 21
command because the switch is inoperable, you can get the WWN from the same place as the serial number, except for the Brocade DCX. For the Brocade DCX, access the numbers on the WWN cards by removing the Brocade logo plate at the top of the non-port side of the chassis. Document feedback - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 22
xxii Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 23
system messages This guide supports Fabric OS v7.1.0 and documents system messages that can help you diagnose and fix problems with a switch or fabric. The messages are organized alphabetically by module name. A module is a subsystem in the Fabric OS. Each module generates a set of numbered messages - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 24
audits and problem determination based on high-frequency events of certain types such as security violations, zoning configuration changes, firmware downloads, and certain types of fabric events. Audit messages flagged as AUDIT are not saved in the switch error logs. The switch can be configured to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 25
uploaded support information to the host with IP address 192.0.2.2. Message severity levels Table 2 shows the four levels of severity for system messages, ranging from CRITICAL (1) to INFO (4). In general, the definitions are wide ranging and are to be used as general guidelines for troubleshooting - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 26
serious problems that perform service reset to 1 using the errClear command. The sequence number is persistent across power cycles and switch reboots. • Trace dump, FFDC, and core dump files can be uploaded to the FTP server using the supportSave command. • Brocade recommends that you configure - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 27
to the syslogd of one or more servers, perform the following steps. 1. Log in to the switch as admin. 2. Execute the syslogdIpAdd IP address command to add a server to which system messages are forwarded. switch:admin> syslogdipadd 192.0.2.2 You can configure up to six syslog servers to receive the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 28
the configured severity level. You can choose one of the following severity levels: INFO, WARNING, ERROR, or CRITICAL. To set the severity levels for the system console, perform the following steps. 1. Log in to the switch as admin. 2. Execute the errFilterSet [-d console -v severity] command to set - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 29
trap, perform the following steps. 1. Log in to the switch as admin. 2. Execute the snmpConfig --set snmpv1 command to configure the SNMP trap recipient. switch:admin> snmpconfig --set snmpv1 SNMP community and trap recipient configuration: Community (rw): [Secret C0de] Trap Recipient's IP address - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 30
the SNMP informs "SNMP Informs Enabled". switch:admin> snmpconfig --set snmpv3 SNMP Informs Enabled (true, t, false, f): [false] SNMPv3 user configuration(snmp user not configured in FOS user database will have physical AD and admin role as the default): User (rw): [snmpadmin1] Auth Protocol [MD5 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 31
the SNMP traps. Brocade devices support SNMPv3 informs. Configuring the SNMPv3 inform recipient To configure the SNMPv3 host to receive the SNMP informs, perform the following steps. 1. Log in to the switch as admin. 2. Execute the snmpConfig --set snmpv3 command to configure the inform recipient - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 32
the SNMP informs, the username, the authentication protocol, the privacy protocol, the UDP port number, and the engine ID must match between the switch and the management station. 3. Execute the snmpConfig --show snmpv3 command to verify the SNMP agent configuration. switch:admin> snmpconfig --show - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 33
logs are typically used to troubleshoot device connections. Changing the severity level of swEventTrap When an event occurs and if the event severity level is at or below the set severity level, the SNMP trap, swEventTrap, is sent to the configured trap recipients. By default, the severity level is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 34
perform the following steps. 1. Log in to the switch as admin. 2. Execute the snmpConfig --set mibCapability command to configure MIBs interactively. All the supported : NO swStateChangeTrap: NO swPortMoveTrap: NO swBrcdGenericTrap: YES ... SW-TRAP (yes, y, no, n): - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 35
portLogEnable portLogEventShow portLoginShow portLogPdisc portLogReset Configures the audit message log. Displays or clears the audit log. Clears all error log messages for all switch instances on this control processor (CP). Sets the error log start and end delimiter for messages pushed to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 36
a list of diagnostic and error display commands. This output is used by your switch service provider to diagnose and correct problems with the switch. The output from this command is very long. syslogdFacility Changes the syslogd facility. syslogdIpAdd Adds an IP address as a recipient of system - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 37
used to enable or disable only the external messages. Configuring event auditing To configure event auditing, perform the following steps. 1. Log in to the switch as admin. 2. Execute the auditCfg --enable command to enable the audit feature. switch:admin> auditcfg --enable Audit filter is enabled - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 38
the syslog server, refer to "Configuring a syslog server" on page 5. Disabling a RASLog message or module To disable a single RASLog message or all messages in a module, perform the following steps. 1. Log in to the switch as admin. 2. Use the following commands to disable a single RASLog message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 39
the rasadmin --show -module module_ID command to verify the status of the messages that belong to a module. Setting the severity level of a RASLog message To change the default severity level of a RASLog message, perform the following steps. 1. Log in to the switch as admin. 2. Use the rasadmin - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 40
message log one message at a time, perform the following steps. 1. Log in to the switch as admin. 2. Enter the errShow command at the command line. switch:admin> errshow Version: v7.1.0 2011/11/11-05:54:30, [HAM-1004], 1, CHASSIS, INFO, switch, Processor rebooted - Reset Type to continue, Q - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 41
, CLI: auditdump -s [...] Displaying FFDC messages To display the saved FFDC messages, perform the following steps. 1. Log in to the switch as admin. 2. Enter the errDump --attribute FFDC command at the command line. switch:admin> errDump --attribute FFDC Fabric OS: v7.1.0 2012/10/15-10:39:02, [LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 42
of the system message, perform the following steps. 1. Log in to the switch as admin. 2. Use the following commands to display the status of module module_ID command to display the status of all messages that belong to the module. switch:admin> rasadmin --show -module ECC Message Status Default - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 43
if the SFP is valid for the configuration. Displaying RASLog messages by message ID To display the RASLog messages based on the message ID, perform the following steps. 1. Log in to the switch as admin. 2. Execute the errdump --message message_ID command. The following example displays all instances - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 44
logs. These procedures are valid for all the supported platforms. Clearing the system message log To clear the system message log for a particular switch instance, perform the following steps. 1. Log in to the switch as admin. 2. Execute the errClear command to clear all messages from memory. NOTE - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 45
FID 128, INFO, ESNSVT_DCX, Login information: Login successful via TELNET/SSH/RSH. IP Addr:192.0.2.2. NOTE Any reference to slot 0 in a system message is a reference to the blade within the switch platform, for example, Brocade DCX contains FC8-48 blade, FC8-32 blade, FC8-16 blade, and so on. The - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 46
post-event auditing and troubleshooting the problem. The following example shows the format of the Audit event message. AUDIT, , [], , , ////, /, - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 47
CFG • CLI • FABRIC • FIRMWARE • FW • LS • MAPS (internal use only) • RAS • SECURITY • ZONE The user ID. The role of the user ID. The IP address. The interface being used. The application name being used on the interface. The Admin Domain, if there is one. The defined switch name or the chassis name - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 48
errDump command on each logical switch. • Execute the supportFtp command (as needed) to set up automatic FTP transfers, and then run the supportSave command. • Document the sequence of events by answering the following questions: - What happened just prior to the problem? - Is the problem repeatable - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 49
Execute the errDump command on each logical switch. • Execute the supportFtp command (as needed) to set up automatic FTP transfers, and then execute the supportSave command. Support Fabric OS creates a number of files that can help support personnel troubleshoot and diagnose a problem. This section - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 50
(EM) module. Fibre Channel over IP port configuration messages over the Brocade 7800 and FX8-24 blade. Blade management error messages are a result of autoleveling firmware upgrades performed by the control processor (CP). C2 error messages indicate problems with the 8 Gbps-capable FC module of the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 51
OS system driver module. Firmware blade compatibility errors with the control processor (CP). Fibre Channel miscellaneous messages relate to problems with the physical layer used to send Fibre Channel traffic to and from the switch. FCoE error messages indicate problems with the FCoE module of the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 52
messages related to port restart failure. System messages generated by the IP admin demon. Fibre Channel over IP license, tunneling, and port-related messages. ISNS server and client status messages. KAC error messages indicate problems associated with Fabric OS and the external key vaults. The - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 53
descriptions 1 TABLE 6 System module descriptions (Continued) System module Description KSWD • Fabric daemon (fabricd) (continued) • Fabric Device Management Interface daemon (fdmid) • Fabric Watch daemon (fwd) • FCoE daemon (fcoed) • Fibre Channel Protocol daemon (fcpd) • FICON CUP - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 54
indicate problems with the Operation, Administration and Maintenance module of the Fabric OS. PDM Parity data manager (PDM) is a user-space daemon responsible for the replication of persistent configuration files from the primary partition to the secondary partition and from the active CP blade to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 55
by users to connect end devices or connect to other switches. The performance server daemon measures the amount of traffic between endpoints or traffic with particular frame formats, such as SCSI frames, IP frames, and customer-defined frames. The portswap feature and associated commands generate - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 56
messages indicate problems with the System Services Module of the Fabric OS. The software upgrade library provides the firmwareDownload command capability, which enables firmware upgrades to both CP blades with a single command, as well as nondisruptive code load to all Fabric OS switches. These - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 57
Log Messages AG Messages AG-1001 AG-1002 AG-1003 AG-1004 AG-1005 AG-1006 AG-1007 AG-1008 AG-1009 AG-1010 AG-1011 AG-1012 AG-1013 AG-1014 AG-1015 AG-1016 AG-1017 AG-1018 AG-1019 AG-1020 AG-1021 AG-1022 AG-1023 AG-1024 AG-1025 AG-1026 AG-1027 AG-1028 Fabric OS Message Reference 53-1002749-01 Chapter - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 58
2 AN Messages AG-1029 AG-1030 AG-1031 AG-1032 AG-1033 AG-1034 AG-1035 AG-1036 AG-1037 AG-1038 AG-1039 AG-1040 AG-1041 AG-1042 AG-1043 AG-1044 AN Messages AN-1001 AN-1002 AN-1003 AN-1004 AN-1005 AN-1010 AN-1011 AN-1012 AN-1013 ANV Messages ANV-1001 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 59
ANV-1006 ANV-1007 ANV-1008 ANV-1015 ANV-1016 ANV-1028 AUTH Messages AUTH-1001 AUTH-1002 AUTH-1003 AUTH-1004 AUTH-1005 AUTH-1006 AUTH-1007 AUTH-1008 AUTH-1010 AUTH-1011 AUTH-1012 AUTH-1013 AUTH-1014 AUTH-1016 AUTH-1017 AUTH-1018 AUTH-1020 AUTH-1022 AUTH-1023 AUTH-1025 AUTH-1026 AUTH-1027 AUTH-1028 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 60
2 BKSW Messages AUTH-1033 AUTH-1034 AUTH-1035 AUTH-1036 AUTH-1037 AUTH-1038 AUTH-1039 AUTH-1040 AUTH-1041 AUTH-1042 AUTH-1043 AUTH-1044 AUTH-1045 AUTH-1046 AUTH-1047 BKSW Messages BKSW-1003 BL Messages BL-1000 BL-1001 BL-1002 BL-1003 BL-1004 BL-1006 BL-1007 BL-1008 BL-1009 BL-1010 BL-1011 BL-1012 BL - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 61
BL-1015 BL-1016 BL-1017 BL-1018 BL-1019 BL-1020 BL-1021 BL-1022 BL-1023 BL-1024 BL-1025 BL-1026 BL-1027 BL-1028 BL-1029 BL-1030 BL-1031 BL-1032 BL-1033 BL-1034 BL-1035 BL-1036 BL-1037 BL-1038 BL-1039 BL-1041 BL-1045 BL-1046 BL-1047 BL-1048 BL-1049 BL-1050 BL-1051 BL-1052 Fabric OS Message Reference - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 62
2 BLS Messages BLS Messages BLS-1000 BLS-1001 BLS-1002 BLS-1003 BLS-1004 BLS-1005 BM Messages BM-1001 BM-1002 BM-1003 BM-1004 BM-1005 BM-1006 BM-1007 BM-1008 BM-1009 BM-1010 BM-1053 BM-1054 BM-1055 BM-1056 BM-1058 C2 Messages C2-1001 C2-1002 C2-1004 C2-1006 C2-1007 C2-1008 C2-1009 C2-1010 40 Fabric - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 63
C2-1012 C2-1013 C2-1014 C2-1015 C2-1016 C2-1017 C2-1018 C2-1019 C2-1025 C2-1026 C2-1027 C2-1028 C3 Messages C3-1001 C3-1002 C3-1004 C3-1006 C3-1007 C3-1008 C3-1009 C3-1010 C3-1011 C3-1012 C3-1013 C3-1014 C3-1015 C3-1016 C3-1017 C3-1018 C3-1019 C3-1020 C3-1021 C3-1023 C3-1025 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 64
2 CAL Messages C3-1026 C3-1027 C3-1028 CAL Messages CAL-1001 CCFG Messages CCFG-1001 CCFG-1002 CCFG-1003 CCFG-1004 CCFG-1005 CCFG-1006 CCFG-1007 CCFG-1008 CCFG-1009 CCFG-1010 CCFG-1011 CCFG-1012 CDR Messages CDR-1001 CDR-1002 CDR-1003 CDR-1004 CDR-1005 CDR-1006 CDR-1007 CDR-1008 CDR-1009 CDR-1010 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 65
CDR-1014 CDR-1015 CDR-1016 CDR-1017 CDR-1018 CDR-1019 CDR-1022 CDR-1028 CHS Messages CHS-1002 CHS-1003 CHS-1004 CHS-1005 CNM Messages CNM-1001 CNM-1002 CNM-1003 CNM-1004 CNM-1005 CNM-1006 CNM-1007 CNM-1008 CNM-1009 CNM-1010 CNM-1011 CNM-1012 CNM-1013 CNM-1014 CNM-1015 CNM-1016 CNM-1017 CNM-1018 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 66
2 CNM Messages CNM-1019 CNM-1020 CNM-1021 CNM-1022 CNM-1023 CNM-1024 CNM-1025 CNM-1026 CNM-1027 CNM-1028 CNM-1029 CNM-1030 CNM-1031 CNM-1032 CNM-1033 CNM-1034 CNM-1035 CNM-1036 CNM-1037 CNM-1038 CNM-1039 CNM-1040 CNM-1041 CNM-1042 CNM-1043 CNM-1044 CNM-1045 CNM-1046 CNM-1047 CNM-1048 CNM-1049 CNM- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 67
CNM-1054 CNM-1055 CNM-1056 CNM-1057 CNM-1058 CNM-1059 CNM-1060 CNM-1061 CNM-1062 CNM-3001 CNM-3002 CNM-3003 CNM-3004 CNM-3005 CNM-3006 CNM-3007 CNM-3008 CNM-3009 CNM-3010 CNM-3011 CNM-3012 CONF Messages CONF-1000 CONF-1001 CONF-1021 CONF-1023 CONF-1024 CONF-1030 CONF-1031 CONF-1032 CONF-1040 CONF- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 68
2 CTAP Messages CONF-1044 CTAP Messages CTAP-1001 CVLC Messages CVLC-1001 CVLC-1002 CVLC-1003 CVLC-1004 CVLC-1005 CVLC-1006 CVLC-1007 CVLC-1008 CVLC-1009 CVLC-1010 CVLC-1011 CVLC-1012 CVLC-1013 CVLC-1014 CVLC-1015 CVLC-1016 CVLC-1017 CVLC-1018 CVLC-1019 CVLC-1020 CVLC-1021 CVLC-1022 CVLC-1023 CVLC- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 69
CVLC-1029 CVLC-1030 CVLC-1031 CVLC-1032 CVLC-1033 CVLC-1034 CVLC-1035 CVLC-1039 CVLC-1041 CVLM Messages CVLM-1001 CVLM-1002 CVLM-1003 CVLM-1004 CVLM-1005 CVLM-1006 CVLM-1007 CVLM-1008 CVLM-1009 CVLM-1010 CVLM-1011 CVLM-1012 CVLM-1013 CVLM-1014 CVLM-1015 CVLM-1016 CVLM-3001 CVLM-3002 CVLM-3003 CVLM- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 70
2 DOT1 Messages CVLM-3009 CVLM-3010 CVLM-3011 CVLM-3012 CVLM-3013 CVLM-3014 CVLM-3015 CVLM-3016 CVLM-3017 CVLM-3018 CVLM-3019 CVLM-3020 CVLM-3021 CVLM-3022 CVLM-3023 CVLM-3024 CVLM-3025 CVLM-3026 CVLM-3027 CVLM-3028 DOT1 Messages DOT1-1001 DOT1-1002 DOT1-1003 DOT1-1004 DOT1-1005 DOT1-1006 DOT1-1007 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 71
ECC Messages ECC-1000 ECC-1001 EM Messages EM-1001 EM-1002 EM-1003 EM-1004 EM-1005 EM-1006 EM-1008 EM-1009 EM-1010 EM-1011 EM-1012 EM-1013 EM-1014 EM-1015 EM-1016 EM-1017 EM-1018 EM-1019 EM-1020 EM-1028 EM-1029 EM-1031 EM-1033 EM-1034 EM-1035 EM-1036 EM-1037 EM-1042 EM-1043 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 72
2 ESS Messages EM-1044 EM-1045 EM-1046 EM-1047 EM-1048 EM-1049 EM-1050 EM-1051 EM-1057 EM-1058 EM-1059 EM-1060 EM-1061 EM-1062 EM-1063 EM-1064 EM-1065 EM-1066 EM-1067 EM-1068 EM-1069 EM-1070 EM-1071 EM-1072 EM-2003 ESS Messages ESS-1001 ESS-1002 ESS-1003 ESS-1004 ESS-1005 ESS-1008 ESS-1009 ESS-1010 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 73
ESW Messages ESW-1001 ESW-1002 ESW-1003 ESW-1004 ESW-1005 ESW-1006 ESW-1007 ESW-1008 EVMD Messages EVMD-1001 FABR Messages FABR-1001 FABR-1002 FABR-1003 FABR-1004 FABR-1005 FABR-1006 FABR-1007 FABR-1008 FABR-1009 FABR-1010 FABR-1011 FABR-1012 FABR-1013 FABR-1014 FABR-1015 FABR-1016 FABR-1017 FABR- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 74
2 FABS Messages FABR-1021 FABR-1022 FABR-1023 FABR-1024 FABR-1029 FABR-1030 FABR-1031 FABR-1032 FABR-1034 FABR-1035 FABR-1036 FABR-1037 FABR-1038 FABR-1039 FABR-1040 FABR-1041 FABR-1043 FABR-1044 FABR-1045 FABR-1046 FABR-1047 FABR-1048 FABR-1049 FABR-1050 FABR-1051 FABR-1052 FABR-1053 FABR-1054 FABR - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 75
FABS-1006 FABS-1007 FABS-1008 FABS-1009 FABS-1010 FABS-1011 FABS-1013 FABS-1014 FABS-1015 FBC Messages FBC-1001 FCMC Messages FCMC-1001 FCOE Messages FCOE-1001 FCOE-1002 FCOE-1003 FCOE-1004 FCOE-1005 FCOE-1006 FCOE-1007 FCOE-1009 FCOE-1010 FCOE-1012 FCOE-1014 FCOE-1015 FCOE-1016 FCOE-1017 FCOE-1019 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 76
2 FCPD Messages FCOE-1023 FCOE-1024 FCOE-1025 FCOE-1026 FCOE-1027 FCOE-1028 FCOE-1029 FCOE-1030 FCOE-1031 FCOE-1032 FCOE-1033 FCOE-1034 FCOE-1037 FCOE-1038 FCOE-1039 FCOE-1040 FCOE-1041 FCOE-1042 FCOE-1043 FCOE-1044 FCOE-1045 FCOE-1046 FCOE-1047 FCOE-1048 FCPD Messages FCPD-1001 FCPD-1002 FCPD-1003 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 77
FCPH-1004 FCPH-1005 FCR Messages FCR-1001 FCR-1002 FCR-1003 FCR-1004 FCR-1005 FCR-1006 FCR-1007 FCR-1008 FCR-1009 FCR-1010 FCR-1011 FCR-1012 FCR-1013 FCR-1015 FCR-1016 FCR-1018 FCR-1019 FCR-1020 FCR-1021 FCR-1022 FCR-1023 FCR-1024 FCR-1025 FCR-1026 FCR-1027 FCR-1028 FCR-1029 FCR-1030 FCR-1031 FCR- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 78
2 FCR Messages FCR-1034 FCR-1035 FCR-1036 FCR-1037 FCR-1038 FCR-1039 FCR-1040 FCR-1041 FCR-1042 FCR-1043 FCR-1048 FCR-1049 FCR-1053 FCR-1054 FCR-1055 FCR-1056 FCR-1057 FCR-1058 FCR-1059 FCR-1060 FCR-1061 FCR-1062 FCR-1063 FCR-1064 FCR-1065 FCR-1066 FCR-1067 FCR-1068 FCR-1069 FCR-1070 FCR-1071 FCR- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 79
FCR-1076 FCR-1077 FCR-1078 FCR-1079 FCR-1080 FCR-1081 FCR-1082 FCR-1083 FCR-1084 FCR-1085 FCR-1086 FCR-1087 FCR-1088 FCR-1089 FCR-1091 FCR-1092 FCR-1093 FCR-1094 FCR-1095 FCR-1096 FCR-1097 FCR-1098 FICN Messages FICN-1003 FICN-1004 FICN-1005 FICN-1006 FICN-1007 FICN-1008 FICN-1009 FICN-1010 FICN- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 80
2 FICN Messages FICN-1014 FICN-1015 FICN-1016 FICN-1017 FICN-1018 FICN-1019 FICN-1020 FICN-1021 FICN-1022 FICN-1023 FICN-1024 FICN-1025 FICN-1026 FICN-1027 FICN-1028 FICN-1029 FICN-1030 FICN-1031 FICN-1032 FICN-1033 FICN-1034 FICN-1035 FICN-1036 FICN-1037 FICN-1038 FICN-1039 FICN-1040 FICN-1041 FICN - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 81
FICN-1049 FICN-1050 FICN-1051 FICN-1052 FICN-1053 FICN-1054 FICN-1055 FICN-1056 FICN-1057 FICN-1058 FICN-1059 FICN-1060 FICN-1061 FICN-1062 FICN-1063 FICN-1064 FICN-1065 FICN-1066 FICN-1067 FICN-1068 FICN-1069 FICN-1070 FICN-1071 FICN-1072 FICN-1073 FICN-1074 FICN-1075 FICN-1076 FICN-1077 FICN-1078 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 82
2 FICN Messages FICN-1084 FICN-1085 FICN-1086 FICN-1087 FICN-1088 FICN-1089 FICN-1090 FICN-1091 FICN-1092 FICN-1093 FICN-1094 FICN-1095 FICN-1096 FICN-1097 FICN-1098 FICN-1099 FICN-1100 FICN-1101 FICN-1102 FICN-1103 FICN-1104 FICN-1105 FICN-1106 FICN-1107 FICN-1108 FICN-1109 FICN-1110 FICN-1111 FICN - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 83
FICN-1119 FICN-1120 FICN-1121 FICN-1122 FICN-2005 FICN-2006 FICN-2064 FICN-2065 FICN-2066 FICN-2082 FICN-2083 FICN-2085 FICN-2086 FICN-2087 FICU Messages FICU-1001 FICU-1002 FICU-1003 FICU-1004 FICU-1005 FICU-1006 FICU-1007 FICU-1008 FICU-1009 FICU-1010 FICU-1011 FICU-1012 FICU-1013 FICU-1017 FICU- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 84
2 FKLB Messages FICU-1023 FICU-1024 FKLB Messages FKLB-1001 FLOD Messages FLOD-1001 FLOD-1003 FLOD-1004 FLOD-1005 FLOD-1006 FSPF Messages FSPF-1001 FSPF-1002 FSPF-1003 FSPF-1005 FSPF-1006 FSPF-1007 FSPF-1008 FSPF-1009 FSPF-1010 FSPF-1011 FSPF-1012 FSS Messages FSS-1001 FSS-1002 FSS-1003 FSS-1004 FSS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 85
FSS-1008 FSS-1009 FSS-1010 FSS-1011 FSSM Messages FSSM-1002 FSSM-1003 FSSM-1004 FW Messages FW-1001 FW-1002 FW-1003 FW-1004 FW-1005 FW-1006 FW-1007 FW-1008 FW-1009 FW-1010 FW-1011 FW-1012 FW-1033 FW-1034 FW-1035 FW-1036 FW-1037 FW-1038 FW-1039 FW-1040 FW-1041 FW-1042 FW-1043 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 86
2 FW Messages FW-1044 FW-1045 FW-1046 FW-1047 FW-1048 FW-1049 FW-1050 FW-1051 FW-1052 FW-1053 FW-1054 FW-1113 FW-1114 FW-1115 FW-1116 FW-1117 FW-1118 FW-1119 FW-1120 FW-1121 FW-1122 FW-1123 FW-1124 FW-1125 FW-1126 FW-1127 FW-1128 FW-1129 FW-1130 FW-1131 FW-1132 FW-1133 FW-1134 FW-1135 FW-1136 64 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 87
FW-1137 FW-1138 FW-1139 FW-1140 FW-1160 FW-1161 FW-1162 FW-1163 FW-1164 FW-1165 FW-1166 FW-1167 FW-1168 FW-1169 FW-1170 FW-1171 FW-1172 FW-1173 FW-1174 FW-1175 FW-1176 FW-1177 FW-1178 FW-1179 FW-1180 FW-1181 FW-1182 FW-1183 FW-1184 FW-1185 FW-1186 FW-1187 FW-1188 FW-1189 FW-1190 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 88
2 FW Messages FW-1191 FW-1192 FW-1193 FW-1194 FW-1195 FW-1196 FW-1197 FW-1198 FW-1199 FW-1200 FW-1201 FW-1202 FW-1203 FW-1204 FW-1205 FW-1206 FW-1207 FW-1216 FW-1217 FW-1218 FW-1219 FW-1240 FW-1241 FW-1242 FW-1243 FW-1244 FW-1245 FW-1246 FW-1247 FW-1248 FW-1249 FW-1250 FW-1251 FW-1272 FW-1273 66 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 89
FW-1274 FW-1275 FW-1296 FW-1297 FW-1298 FW-1299 FW-1300 FW-1301 FW-1302 FW-1303 FW-1304 FW-1305 FW-1306 FW-1307 FW-1308 FW-1309 FW-1310 FW-1311 FW-1312 FW-1313 FW-1314 FW-1315 FW-1316 FW-1317 FW-1318 FW-1319 FW-1320 FW-1321 FW-1322 FW-1323 FW-1324 FW-1325 FW-1326 FW-1327 FW-1328 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 90
2 FW Messages FW-1329 FW-1330 FW-1331 FW-1332 FW-1333 FW-1334 FW-1335 FW-1336 FW-1337 FW-1338 FW-1339 FW-1340 FW-1341 FW-1342 FW-1343 FW-1344 FW-1345 FW-1346 FW-1347 FW-1348 FW-1349 FW-1350 FW-1351 FW-1352 FW-1353 FW-1354 FW-1355 FW-1356 FW-1357 FW-1358 FW-1359 FW-1360 FW-1361 FW-1362 FW-1363 68 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 91
FW-1364 FW-1365 FW-1366 FW-1367 FW-1368 FW-1369 FW-1370 FW-1371 FW-1372 FW-1373 FW-1374 FW-1375 FW-1376 FW-1377 FW-1378 FW-1379 FW-1400 FW-1401 FW-1402 FW-1403 FW-1404 FW-1405 FW-1406 FW-1407 FW-1408 FW-1424 FW-1425 FW-1426 FW-1427 FW-1428 FW-1429 FW-1430 FW-1431 FW-1432 FW-1433 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 92
2 FW Messages FW-1434 FW-1435 FW-1436 FW-1437 FW-1438 FW-1439 FW-1440 FW-1441 FW-1442 FW-1443 FW-1444 FW-1445 FW-1446 FW-1447 FW-1448 FW-1500 FW-1501 FW-1502 FW-1510 FW-1511 FW-1512 FW-1513 FW-1514 FW-1515 FW-1516 FW-1517 FW-1518 FW-1519 FW-1520 FW-1521 FW-1522 FW-1523 FW-1524 FW-1525 FW-1526 70 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 93
FW-1527 FW-1528 FW-1529 FW-1530 FW-1531 FW-1532 FW-1533 FW-1534 FW-1535 FW-2000 FW-3010 FW-3011 FW-3012 FW-3013 FW-3014 FW-3015 FW-3016 FW-3017 FW-3018 FW-3019 FW-3020 FW-3021 FW-3022 HAM Messages HAM-1001 HAM-1002 HAM-1004 HAM-1005 HAM-1006 HAM-1007 HAM-1008 HAM-1009 HAM-1010 HAM-1011 Fabric OS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 94
2 HAMK Messages HAM-1013 HAM-1014 HAMK Messages HAMK-1001 HAMK-1002 HAMK-1003 HAMK-1004 HIL Messages HIL-1101 HIL-1102 HIL-1103 HIL-1104 HIL-1105 HIL-1106 HIL-1107 HIL-1108 HIL-1201 HIL-1202 HIL-1203 HIL-1204 HIL-1206 HIL-1207 HIL-1208 HIL-1301 HIL-1302 HIL-1303 HIL-1304 HIL-1305 HIL-1306 HIL-1307 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 95
HIL-1310 HIL-1311 HIL-1401 HIL-1402 HIL-1403 HIL-1404 HIL-1501 HIL-1502 HIL-1503 HIL-1504 HIL-1505 HIL-1506 HIL-1507 HIL-1508 HIL-1509 HIL-1510 HIL-1511 HIL-1601 HIL-1602 HIL-1603 HIL-1605 HIL-1610 HIL-1611 HIL-1612 HIL-1613 HIL-1650 HLO Messages HLO-1001 HLO-1002 HLO-1003 HMON Messages HMON-1001 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 96
-1007 HTTP Messages HTTP-1001 HTTP-1002 HTTP-1003 IBD Messages IBD-1000 IPAD Messages IPAD-1000 IPAD-1001 IPAD-1002 IPAD-1003 IPAD-1004 IPS Messages IPS-1001 IPS-1002 IPS-1003 IPS-1004 IPS-1005 IPS-1006 IPS-1007 74 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 97
ISNS Messages ISNS-1001 ISNS-1002 ISNS-1003 ISNS-1004 ISNS-1005 ISNS-1006 ISNS-1008 ISNS-1009 ISNS-1010 ISNS-1011 ISNS-1013 ISNS-1014 KAC Messages KAC-1002 KAC-1004 KAC-1006 KAC-1007 KAC-1008 KAC-1009 KAC-1010 KAC-1011 KAC-1012 KAC-1013 KAC-1014 KAC-1015 KAC-1016 KAC-1017 KSWD Messages KSWD-1001 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 98
2 KTRC Messages KTRC Messages KTRC-1001 KTRC-1002 KTRC-1003 KTRC-1004 KTRC-1005 L2SS Messages L2SS-1001 L2SS-1002 L2SS-1003 L2SS-1004 L2SS-1005 L2SS-1006 L2SS-1007 L2SS-1008 L3SS Messages L3SS-1004 LACP Messages LACP-1001 LACP-1002 LANCE Messages LANCE-1000 LFM Messages LFM-1001 LFM-1002 LFM-1003 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 99
LFM-1006 LOG Messages LOG-1000 LOG-1001 LOG-1002 LOG-1003 LOG-1004 LOG-1005 LOG-1006 LOG-1007 LOG-1008 LOG-1009 LOG-1010 LOG-1011 LSDB Messages LSDB-1001 LSDB-1002 LSDB-1003 LSDB-1004 MCAST_SS Messages MCAST_SS-1001 MCAST_SS-1002 MCAST_SS-1003 MCAST_SS-1004 MCAST_SS-1005 MCAST_SS-1006 MCAST_SS-1007 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 100
2 MFIC Messages MCAST_SS-1012 MCAST_SS-1013 MCAST_SS-1014 MCAST_SS-1015 MCAST_SS-1016 MCAST_SS-1017 MCAST_SS-1018 MCAST_SS-1019 MCAST_SS-1020 MFIC Messages MFIC-1001 MFIC-1002 MFIC-1003 MM Messages MM-1001 MPTH Messages MPTH-1001 MPTH-1002 MPTH-1003 MQ Messages MQ-1004 MQ-1005 MQ-1006 MS Messages MS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 101
MS-1006 MS-1008 MS-1009 MS-1021 MS-1022 MS-1023 MS-1024 MS-1025 MS-1026 MS-1027 MS-1028 MS-1029 MS-1030 MSTP Messages MSTP-1001 MSTP-1002 MSTP-1003 MSTP-2001 MSTP-2002 MSTP-2003 MSTP-2004 MSTP-2005 MSTP-2006 NBFS Messages NBFS-1001 NBFS-1002 NBFS-1003 NBFS-1004 NS Messages NS-1001 NS-1002 Fabric OS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 102
2 NSM Messages NS-1003 NS-1004 NS-1005 NS-1006 NS-1007 NS-1008 NS-1009 NS-1010 NS-1011 NS-1012 NSM Messages NSM-1001 NSM-1002 NSM-1003 NSM-1004 NSM-1005 NSM-1006 NSM-1007 NSM-1008 NSM-1009 NSM-1010 NSM-1011 NSM-1012 NSM-1013 NSM-1014 NSM-1015 NSM-1016 NSM-1017 NSM-1018 NSM-1019 NSM-1020 80 Fabric - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 103
ONMD Messages ONMD-1000 ONMD-1001 ONMD-1002 ONMD-1003 ONMD-1004 ONMD-1005 PDM Messages PDM-1001 PDM-1002 PDM-1003 PDM-1004 PDM-1005 PDM-1006 PDM-1007 PDM-1008 PDM-1009 PDM-1010 PDM-1011 PDM-1012 PDM-1013 PDM-1014 PDM-1017 PDM-1019 PDM-1020 PDM-1021 PDM-1022 PDM-1023 PDM-1024 PDM-1025 PDM-1026 Fabric - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 104
2 PDTR Messages PDTR Messages PDTR-1001 PDTR-1002 PLAT Messages PLAT-1000 PLAT-1001 PLAT-1002 PLAT-1003 PLAT-1004 PLAT-1072 PMGR Messages PMGR-1001 PMGR-1002 PMGR-1003 PMGR-1004 PMGR-1005 PMGR-1006 PMGR-1007 PMGR-1008 PMGR-1009 PMGR-1010 PMGR-1011 PORT Messages PORT-1003 PORT-1004 PORT-1005 PORT- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 105
PS Messages PS-1000 PS-1001 PS-1002 PS-1003 PS-1004 PS-1005 PS-1006 PS-1007 PS-1008 PS-1009 PS-1010 PSWP Messages PSWP-1001 PSWP-1002 PSWP-1003 PSWP-1004 PSWP-1005 PSWP-1006 PSWP-1007 RAS Messages RAS-1001 RAS-1002 RAS-1004 RAS-1005 RAS-1006 RAS-1007 RAS-2001 RAS-2002 RAS-2003 RAS-3001 RAS-3002 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 106
2 RCS Messages RAS-3003 RAS-3004 RCS Messages RCS-1001 RCS-1002 RCS-1003 RCS-1004 RCS-1005 RCS-1006 RCS-1007 RCS-1008 RCS-1009 RCS-1010 RCS-1011 RCS-1012 RCS-1013 RKD Messages RKD-1001 RKD-1002 RKD-1003 RKD-1004 RKD-1005 RMON Messages RMON-1001 RMON-1002 RPCD Messages RPCD-1001 RPCD-1002 RPCD-1003 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 107
RPCD-1005 RPCD-1006 RPCD-1007 RTE Messages RTE-1001 RTWR Messages RTWR-1001 RTWR-1002 RTWR-1003 SCN Messages SCN-1001 SCN-1002 SEC Messages SEC-1001 SEC-1002 SEC-1003 SEC-1005 SEC-1006 SEC-1007 SEC-1008 SEC-1009 SEC-1010 SEC-1016 SEC-1022 SEC-1024 SEC-1025 SEC-1026 SEC-1028 SEC-1029 SEC-1030 Fabric - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 108
2 SEC Messages SEC-1031 SEC-1032 SEC-1033 SEC-1034 SEC-1035 SEC-1036 SEC-1037 SEC-1038 SEC-1039 SEC-1040 SEC-1041 SEC-1042 SEC-1043 SEC-1044 SEC-1045 SEC-1046 SEC-1049 SEC-1050 SEC-1051 SEC-1052 SEC-1053 SEC-1054 SEC-1055 SEC-1056 SEC-1057 SEC-1059 SEC-1062 SEC-1063 SEC-1064 SEC-1065 SEC-1069 SEC- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 109
SEC-1075 SEC-1076 SEC-1077 SEC-1078 SEC-1079 SEC-1080 SEC-1081 SEC-1082 SEC-1083 SEC-1084 SEC-1085 SEC-1086 SEC-1087 SEC-1088 SEC-1089 SEC-1090 SEC-1091 SEC-1092 SEC-1093 SEC-1094 SEC-1095 SEC-1096 SEC-1097 SEC-1098 SEC-1099 SEC-1100 SEC-1101 SEC-1102 SEC-1104 SEC-1105 SEC-1106 SEC-1107 SEC-1108 SEC - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 110
2 SEC Messages SEC-1112 SEC-1113 SEC-1114 SEC-1115 SEC-1116 SEC-1117 SEC-1118 SEC-1119 SEC-1121 SEC-1122 SEC-1123 SEC-1124 SEC-1126 SEC-1130 SEC-1135 SEC-1136 SEC-1137 SEC-1138 SEC-1139 SEC-1142 SEC-1145 SEC-1146 SEC-1153 SEC-1154 SEC-1155 SEC-1156 SEC-1157 SEC-1158 SEC-1159 SEC-1160 SEC-1163 SEC- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 111
SEC-1168 SEC-1170 SEC-1171 SEC-1172 SEC-1173 SEC-1174 SEC-1175 SEC-1176 SEC-1180 SEC-1181 SEC-1182 SEC-1183 SEC-1184 SEC-1185 SEC-1186 SEC-1187 SEC-1188 SEC-1189 SEC-1190 SEC-1191 SEC-1192 SEC-1193 SEC-1194 SEC-1195 SEC-1196 SEC-1197 SEC-1198 SEC-1199 SEC-1200 SEC-1201 SEC-1202 SEC-1203 SEC-1250 SEC - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 112
2 SEC Messages SEC-1300 SEC-1301 SEC-1302 SEC-1303 SEC-1304 SEC-1305 SEC-1306 SEC-1307 SEC-1308 SEC-1309 SEC-1310 SEC-1311 SEC-1312 SEC-1313 SEC-1314 SEC-1315 SEC-1316 SEC-1317 SEC-1318 SEC-1319 SEC-1320 SEC-1321 SEC-1322 SEC-1323 SEC-1324 SEC-1325 SEC-1326 SEC-1327 SEC-1328 SEC-1329 SEC-1330 SEC- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 113
SEC-1335 SEC-1336 SEC-1337 SEC-1338 SEC-1339 SEC-3035 SEC-3036 SEC-3037 SEC-3038 SEC-3039 SEC-3050 SEC-3051 SEC-3061 SEC-3062 SEC-3063 SEC-3064 SEC-3065 SEC-3066 SEC-3067 SEC-4001 SFLO Messages SFLO-1001 SFLO-1002 SFLO-1003 SFLO-1004 SFLO-1005 SFLO-1006 SFLO-1007 SFLO-1008 SNMP Messages SNMP-1001 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 114
2 SPC Messages SNMP-1003 SNMP-1004 SNMP-1005 SNMP-1006 SNMP-1009 SPC Messages SPC-1001 SPC-1002 SPC-1003 SPC-2001 SPC-2002 SPC-2003 SPC-2004 SPC-2005 SPC-2006 SPC-2007 SPC-2008 SPC-2009 SPC-2010 SPC-2011 SPC-2012 SPC-2013 SPC-2014 SPC-2040 SPC-2041 SPC-2042 SPC-2043 SPC-2044 SPC-3001 SPC-3002 SPC- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 115
SPC-3007 SPC-3008 SPC-3009 SPC-3010 SPC-3011 SPC-3012 SPC-3013 SPC-3014 SPC-3015 SPM Messages SPM-1001 SPM-1002 SPM-1003 SPM-1004 SPM-1005 SPM-1006 SPM-1007 SPM-1008 SPM-1009 SPM-1010 SPM-1011 SPM-1012 SPM-1013 SPM-1014 SPM-1015 SPM-1016 SPM-3001 SPM-3002 SPM-3003 SPM-3004 SPM-3005 SPM-3006 SPM-3007 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 116
2 SS Messages SPM-3009 SPM-3010 SPM-3011 SPM-3012 SPM-3013 SPM-3014 SPM-3015 SPM-3016 SPM-3017 SPM-3018 SPM-3019 SPM-3020 SPM-3021 SPM-3022 SPM-3023 SPM-3024 SPM-3025 SPM-3026 SPM-3027 SPM-3028 SPM-3029 SS Messages SS-1000 SS-1001 SS-1002 SS-1003 SS-1004 SS-1005 SS-1006 SS-1007 SS-1008 SS-1009 SS- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 117
SS-1012 SSMD Messages SSMD-1001 SSMD-1002 SSMD-1003 SSMD-1004 SSMD-1005 SSMD-1006 SSMD-1007 SSMD-1008 SSMD-1200 SSMD-1201 SSMD-1202 SSMD-1203 SSMD-1204 SSMD-1205 SSMD-1206 SSMD-1207 SSMD-1208 SSMD-1209 SSMD-1210 SSMD-1211 SSMD-1212 SSMD-1213 SSMD-1214 SSMD-1215 SSMD-1216 SSMD-1217 SSMD-1300 SSMD- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 118
2 SULB Messages SSMD-1306 SSMD-1307 SSMD-1308 SSMD-1309 SSMD-1310 SSMD-1311 SSMD-1312 SSMD-1313 SSMD-1314 SSMD-1315 SSMD-1316 SSMD-1317 SSMD-1318 SULB Messages SULB-1001 SULB-1002 SULB-1003 SULB-1004 SULB-1005 SULB-1006 SULB-1007 SULB-1008 SULB-1009 SULB-1010 SULB-1011 SULB-1017 SULB-1018 SULB-1020 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 119
SULB-1030 SULB-1031 SULB-1032 SULB-1033 SULB-1034 SULB-1035 SULB-1036 SULB-1037 SULB-1038 SULB-1039 SULB-1040 SULB-1041 SULB-1042 SULB-1043 SULB-1044 SWCH Messages SWCH-1001 SWCH-1002 SWCH-1003 SWCH-1004 SWCH-1005 SWCH-1006 SWCH-1007 SWCH-1008 SWCH-1009 SWCH-1010 SWCH-1011 SWCH-1012 SWCH-1013 SWCH- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 120
2 SYSC Messages SWCH-1019 SWCH-1020 SWCH-1021 SWCH-1022 SWCH-1023 SWCH-1024 SWCH-1025 SWCH-1026 SYSC Messages SYSC-1001 SYSC-1002 SYSC-1004 SYSC-1005 SYSM Messages SYSM-1001 SYSM-1002 SYSM-1003 SYSM-1004 SYSM-1005 SYSM-1006 SYSM-1007 TAPE Messages TAPE-1001 TRCE Messages TRCE-1001 TRCE-1002 TRCE- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 121
TRCE-1007 TRCE-1008 TRCE-1009 TRCE-1010 TRCE-1011 TRCE-1012 TRCE-1013 TRCK Messages TRCK-1001 TRCK-1002 TRCK-1003 TRCK-1004 TRCK-1005 TRCK-1006 TS Messages TS-1001 TS-1002 TS-1006 TS-1007 TS-1008 UCST Messages UCST-1003 UCST-1007 UCST-1020 UCST-1021 UCST-1022 UCST-1023 UCST-1024 UCST-1026 UCST-1027 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 122
2 UPTH Messages UPTH Messages UPTH-1001 UPTH-1002 VDR Messages VDR-2001 VS Messages VS-1001 VS-1002 VS-1003 VS-1004 VS-1005 VS-1006 VS-1007 VS-1008 WEBD Messages WEBD-1001 WEBD-1002 WEBD-1004 WEBD-1005 WEBD-1006 WEBD-1007 WEBD-1008 XTUN Messages XTUN-1000 XTUN-1001 XTUN-1002 XTUN-1003 XTUN-1004 XTUN - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 123
XTUN-1006 XTUN-1007 XTUN-1996 XTUN-1997 XTUN-1998 XTUN-1999 XTUN-2000 XTUN-2001 XTUN-2002 XTUN-2003 XTUN-2004 XTUN-2005 XTUN-2006 XTUN-2007 XTUN-2008 XTUN-2009 XTUN-2010 XTUN-2011 XTUN-2020 XTUN-2021 XTUN-2022 XTUN-2023 XTUN-2024 XTUN-2025 ZEUS Messages ZEUS-1001 ZEUS-1002 ZEUS-1003 ZEUS-1004 ZEUS- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 124
2 ZONE Messages ZONE Messages ZONE-1002 ZONE-1003 ZONE-1004 ZONE-1007 ZONE-1010 ZONE-1013 ZONE-1015 ZONE-1017 ZONE-1019 ZONE-1022 ZONE-1023 ZONE-1024 ZONE-1026 ZONE-1027 ZONE-1028 ZONE-1029 ZONE-1034 ZONE-1036 ZONE-1037 ZONE-1038 ZONE-1039 ZONE-1040 ZONE-1041 ZONE-1042 ZONE-1043 ZONE-1044 ZONE-1045 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 125
ZONE-1059 ZONE-1060 ZONE-1061 ZONE-1062 ZONE Messages 2 Fabric OS Message Reference 103 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 126
2 ZONE Messages 104 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 127
Audit Messages AG Messages AG-1033 AG-1034 AG-1035 AG-1036 AG-1037 AN Messages AN-1003 AN-1004 AN-1005 AN-1006 AN-1010 AN-1011 AN-1012 AN-1013 AUTH Messages AUTH-1045 AUTH-1046 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 128
3 BLS Messages BLS Messages BLS-1002 BLS-1003 CCFG Messages CCFG-1002 CCFG-1003 CCFG-1013 CNM Messages CNM-3001 CNM-3002 CNM-3003 CNM-3004 CNM-3005 CNM-3006 CNM-3007 CNM-3008 CNM-3009 CNM-3010 CNM-3011 CNM-3012 CONF Messages CONF-1000 CONF-1020 CONF-1022 CONF-1042 CONF-1043 CONF-1044 CVLM Messages - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 129
CVLM-3002 CVLM-3003 CVLM-3004 CVLM-3005 CVLM-3006 CVLM-3007 CVLM-3008 CVLM-3009 CVLM-3010 CVLM-3011 CVLM-3012 CVLM-3013 CVLM-3014 CVLM-3015 CVLM-3016 CVLM-3017 CVLM-3018 CVLM-3019 CVLM-3020 CVLM-3021 CVLM-3022 CVLM-3023 CVLM-3024 CVLM-3025 CVLM-3026 CVLM-3027 CVLM-3028 ESS Messages ESS-1008 ESS-1009 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 130
3 FICU Messages FICU Messages FICU-1011 FICU-1012 FICU-1019 FICU-1020 FICU-1021 FW Messages FW-1202 FW-1274 FW-1402 FW-1404 FW-1405 FW-1406 FW-3001 HAM Messages HAM-1015 HTTP Messages HTTP-1002 HTTP-1003 IPAD Messages IPAD-1002 LOG Messages LOG-1005 LOG-1006 LOG-1007 LOG-1008 LOG-1011 108 Fabric OS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 131
MS Messages MS-1027 MS-1028 MS-1029 MS-1030 PMGR Messages PMGR-1001 PMGR-1003 PORT Messages PORT-1006 PORT-1007 PORT-1008 PORT-1009 RAS Messages RAS-2001 RAS-2002 RAS-2003 RAS-3005 SEC Messages SEC-1113 SEC-1114 SEC-1337 SEC-3001 SEC-3002 SEC-3003 SEC-3004 SEC-3005 SEC-3006 SEC-3007 Fabric OS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 132
3 SEC Messages SEC-3008 SEC-3009 SEC-3010 SEC-3011 SEC-3012 SEC-3013 SEC-3014 SEC-3015 SEC-3016 SEC-3017 SEC-3018 SEC-3019 SEC-3020 SEC-3021 SEC-3022 SEC-3023 SEC-3024 SEC-3025 SEC-3026 SEC-3027 SEC-3028 SEC-3029 SEC-3030 SEC-3031 SEC-3032 SEC-3033 SEC-3034 SEC-3035 SEC-3036 SEC-3037 SEC-3038 SEC- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 133
SEC-3047 SEC-3048 SEC-3049 SEC-3050 SEC-3051 SEC-3061 SEC-3062 SEC-3063 SEC-3064 SEC-3065 SEC-3066 SEC-3067 SEC-4001 SNMP Messages SNMP-1004 SNMP-1005 SNMP-1006 SNMP-1009 SPM Messages SPM-3001 SPM-3002 SPM-3003 SPM-3004 SPM-3005 SPM-3006 SPM-3007 SPM-3008 SPM-3009 SPM-3010 SPM-3011 SPM-3012 SPM-3013 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 134
3 SULB Messages SPM-3014 SPM-3015 SPM-3016 SPM-3017 SPM-3018 SPM-3019 SPM-3020 SPM-3021 SPM-3022 SPM-3023 SPM-3024 SPM-3025 SPM-3026 SPM-3027 SPM-3028 SPM-3029 SULB Messages SULB-1001 SULB-1002 SULB-1003 SULB-1004 SULB-1009 SULB-1010 SULB-1017 SULB-1018 SULB-1020 SULB-1021 SULB-1023 SULB-1024 SULB- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 135
SULB-1034 SULB-1035 SULB-1037 SULB-1038 SULB-1039 SULB-1040 SULB-1041 SULB-1042 SWCH Messages SWCH-1012 SWCH-1013 SWCH-1014 UCST Messages UCST-1021 UCST-1022 UCST-1023 UCST-1024 UCST-1026 UCST-1027 ZONE Messages ZONE-3001 ZONE-3002 ZONE-3003 ZONE-3004 ZONE-3005 ZONE-3006 ZONE-3007 ZONE-3008 ZONE- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 136
3 ZONE Messages ZONE-3012 ZONE-3013 ZONE-3014 ZONE-3015 ZONE-3016 ZONE-3017 ZONE-3018 ZONE-3019 ZONE-3020 ZONE-3021 ZONE-3022 ZONE-3023 ZONE-3024 ZONE-3025 ZONE-3026 114 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 137
FFDC Messages ANV Messages ANV-1002 AUTH Messages AUTH-1014 AUTH-1044 BKSW Messages BKSW-1003 BL Messages BL-1002 BL-1003 BL-1004 BL-1008 BL-1009 BL-1011 BL-1016 BL-1020 BLS Messages BLS-1000 BLS-1001 BM Messages BM-1003 BM-1053 Fabric OS Message Reference 53-1002749-01 Chapter 4 115 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 138
4 C2 Messages C2 Messages C2-1002 C2-1012 C3 Messages C3-1002 C3-1012 CDR Messages CDR-1002 CHS Messages CHS-1002 EM Messages EM-1001 EM-1002 EM-1003 EM-1004 EM-1005 EM-1006 EM-1008 EM-1009 EM-1010 EM-1011 EM-1012 EM-1018 EM-1020 EM-1028 EM-1068 EM-1071 EM-1072 116 Fabric OS Message Reference 53- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 139
FABR Messages FABR-1011 FABR-1013 FABR-1019 FABR-1020 FABR-1021 FABR-1022 FABR-1031 FABR-1054 FABS Messages FABS-1001 FCMC Messages FCMC-1001 FCPH Messages FCPH-1001 FLOD Messages FLOD-1004 HAM Messages HAM-1001 HAM-1006 HAM-1007 HAM-1008 HAM-1009 HAM-1011 HAMK Messages HAMK-1001 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 140
4 HIL Messages HIL Messages HIL-1107 HIL-1108 HIL-1502 HIL-1503 HIL-1506 HIL-1507 HIL-1508 HIL-1509 HIL-1602 HIL-1603 HIL-1611 HLO Messages HLO-1001 HLO-1002 HMON Messages HMON-1001 KSWD Messages KSWD-1001 KSWD-1002 LFM Messages LFM-1004 LOG Messages LOG-1001 LOG-1002 LSDB Messages LSDB-1003 118 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 141
MPTH Messages MPTH-1001 MPTH-1002 NBFS Messages NBFS-1002 PDM Messages PDM-1017 PLAT Messages PLAT-1000 PLAT-1003 PLAT-1004 PLAT-1072 PS Messages PS-1000 RAS Messages RAS-1004 RAS-1005 RCS Messages RCS-1012 RCS-1013 SCN Messages SCN-1001 SCN-1002 Fabric OS Message Reference 53-1002749-01 MPTH - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 142
4 SNMP Messages SNMP Messages SNMP-1004 SYSC Messages SYSC-1001 SYSC-1002 SYSM Messages SYSM-1001 SYSM-1005 SYSM-1006 TRCE Messages TRCE-1008 UCST Messages UCST-1007 WEBD Messages WEBD-1008 ZEUS Messages ZEUS-1002 120 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 143
command to enable NPIV capability on the port connected to the Access Gateway. • Some blades and ports in a switch may not support NPIV. NPIV functionality cannot be enabled on such ports and they will not respond to NPIV requests. Refer to the Access Gateway Administrator's Guide for specific AG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 144
, although it is not a supported configuration. Recommended Action Configure two or more N_Ports to connect to the same fabric; then execute the ag --failoverenable command to enable failover on these N_Ports. AG-1004 Message Invalid response to fabric login (FLOGI) request from the fabric - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 145
Recommended Action Check the configuration of the fabric switch connected to the Access Gateway. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 146
Action Check the configuration of the fabric switch connected to the Access Gateway. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AG-1010 Message Sending - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 147
Action Check the configuration of the fabric switch connected to the Access Gateway. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AG-1013 Message F_Ports - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 148
configured using the portCfgShow command. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AG ag --mapshow command to display updated F_Port-to-N_Port mapping. AG- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 149
Cause Indicates that F_Port-to-N_Port mapping has been changed because the switch has come online or some new N_Ports or F_Ports have come online. Recommended Action Execute the ag --mapshow command to display the updated F_Port-to-N_Port mapping. Fabric OS Message Reference 127 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 150
connected to different fabrics is not supported. Recommended Action Change the preferred N_Port settings of the specified F_Port using the ag --prefset command . Recommended Action Execute the ag --mapshow command to display the updated F_Port-to-N_Port mapping. AG-1023 Message F_Port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 151
the configure command on the Access Gateway switch and increase the number of allowed logins on the specified port. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 152
on the specified port. Recommended Action Execute the portCfgNpivPort command on the Access Gateway switch to enable the NPIV capability on the port. AG-1028 Message Device with Port WWN tried to perform fabric login through port , without having access permission. Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 153
>. Message Type LOG Severity WARNING Probable Cause Indicates that a routing loop is detected for the device connected to the specified port. Recommended Action Check the device configuration. AG-1032 Message N_Port (ID: ) has recovered from an unreliable state. Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 154
Cause Indicates that the F_Ports mapped to an N_Port have changed and the configuration file has been updated. Recommended Action No action is required. AG-1034 Message F_Port cannot accept any more logins (). Message Type AUDIT | LOG Class CFG Severity INFO Probable Cause Indicates - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 155
connected to a non-Brocade fabric. Recommended Action Refer to the Access Gateway Administrator's Guide for the supported configuration. AG-1037 Message Trunked N_Port () going offline. If switchshow CLI for the connected fabric switch switchShow command on the connected fabric switch - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 156
an error. AG-1040 Message PID of the devices connected to Port may have changed, as the port was toggled. Check EE monitor configuration as it might not be functional. Message Type LOG Severity WARNING Probable Cause Indicates that N_Port ID virtualization (NPIV) assigns a new - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 157
Check the configuration of the fabric switch connected to the Access Gateway. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AG-1043 Message Authentication - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 158
using the memShow command. Restart or power cycle the switch. AN-1002 Message Failed to initialize; rc = . Message Type LOG Severity ERROR Probable Cause Indicates that the initialization of the "trafd" daemon has failed. Recommended Action Download a new firmware version using the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 159
examine the connected device for the source of the latency. If the port is a long-distance E_Port, make sure that there are enough buffer credits to service the link action is required. AN-1006 Message Bottleneck detection configuration is successfully changed. Message Type AUDIT Class FABRIC - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 160
to determine whether there is complete credit loss on a virtual channel (VC) at the specified port are used by port mirroring. Recommended Action Contact your switch service provider for assistance. AN-1012 Message Credits did not return from other end. Complete loss of credits on a VC on slot - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 161
AN-1013 5 AN-1013 Message Performed link reset to recover the port credits on slot port . Message Type LOG | AUDIT Class FABRIC Severity INFO Probable Cause - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 162
Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not deteriorated, and the Fibre Channel cable is bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To recover a non-bladed system, execute the fastBoot command on the switch. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 163
pointer, chan:, good_addr:0x bad_addr:0x. Message Type next maintenance window. If the problem persists, replace the blade. ANV-1005 Message S - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 164
the specified port is re-initialized due to link reset failure. Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. 142 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 165
Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. ANV-1028 Message Detected excessive Link resets on the port in a second. Slot , Port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 166
; then execute the supportSave command and contact your switch service provider. AUTH-1003 Message type has been successfully set to . Message Type LOG Severity INFO Probable Cause Indicates that an authentication configuration value was set to a specified value. The - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 167
to reinstall the firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-1006 Message Failed to open authentication configuration file. Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 168
local port. Recommended Action Execute the authUtil command to make sure the local switch supports the Fibre Channel Authentication Protocol (FCAP) or Diffie Hellman - Channel Authentication Protocol (DH-CHAP) protocols. AUTH-1008 Message No security license, operation failed. Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 169
using the portDisable and portEnable commands or the switchDisable and switchEnable commands. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-1012 Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 170
using the portDisable and portEnable commands or the switchDisable and switchEnable commands. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 148 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 171
using the portDisable and portEnable commands or the switchDisable and switchEnable commands. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-1020 Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 172
invalid entity tried to connect to the switch. Check the connection port for a reset the secret value for DH-CHAP properly. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 173
authentication phase. This indicates that the local switch does not support the specified authentication value. Recommended Action Check the authentication configuration and reset the supported value if needed using the authUtil command. Reinitialize authentication using the portDisable and - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 174
commands or the switchDisable and switchEnable commands. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service certain phase. Usually this problem is transient. The authentication - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 175
execute the supportSave command and contact your switch service provider. AUTH-1033 Message Disable port due to unauthorized switch . Message Type LOG Severity ERROR Probable Cause Indicates that an entity was not configured in the Switch Connection Control (SCC - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 176
using the portDisable and portEnable commands or the switchDisable and switchEnable commands. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 154 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 177
. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-1039 Message Neighboring switch has conflicting authentication policy: Port disabled. Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 178
commands. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service the specified port has been disabled because the connecting switch or device failed to authenticate. The error may - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 179
and reinitialize authentication using the portDisable and portEnable commands. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-1043 Message Failed to enforce - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 180
operation has been updated using the secAuthCertificate command. The values for Operation type can be "set" or " command again. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 181
Class SECURITY Severity INFO Probable Cause Indicates that an authentication configuration value was set to a specified value. The Data type can be Indicates that the secret database operation has been updated using the secAuthSecret command. Recommended Action No action is required. AUTH- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 182
configuration settings. Otherwise, the E_Port will form without authentication. Recommended Action If the specified port is disabled, correct the switch policy configuration on either of the switches using the authUtil command connect to the switch. 160 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 183
and reinitialize authentication using the portDisable and portEnable commands. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-3007 Message Event: - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 184
daemons is found to be nonresponsive; sending signal abort (SIGABRT). Recommended Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 162 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 185
Self-Test (POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. Additional blade fault messages precede and follow this error, providing more - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 186
but was not faulted due to a user setting. Recommended Action Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 187
) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. If the message persists, replace the blade. BL-1009 Message Blade in slot timed - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 188
slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. If the message persists, replace the blade. BL-1010 Message Blade in slot inconsistent with the hardware settings. Message Type - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 189
to a user port number. Recommended Action Make sure to capture the console output during this process. Check for a faulty cable, small form-factor pluggable (SFP) transceiver, or device attached to the specified port. On a bladed switch, run the slotPowerOff and slotPowerOn commands to power - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 190
is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. On a non-bladed switch, execute the reboot command to restart the switch. If there is a hardware - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 191
) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. If the message persists, replace the blade. BL-1017 Message Slot Initializing - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 192
Number>, internal port retry initialization, . Message Type LOG Severity INFO Probable Cause Indicates that the switch had internal ports that are not online. Initiated a retry on ports that failed to go online. Recommended Action No action is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 193
commands. If the message persists, replace the blade. BL-1024 Message All ports on the blade in slot will be reset as part of the firmware upgrade. Message Type LOG Severity INFO Probable Cause Indicates that a recent firmware upgrade caused the blade firmware to be upgraded - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 194
Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all the Gigabit Ethernet, Fibre Channel over IP (FCIP), virtualization data elements, and FC Fastwrite ports were reset. Recommended Action No action - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 195
Indicates that a recent firmware upgrade caused the switch internal processor firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all Gigabit Ethernet, Fibre Channel over IP (FCIP), virtualization data elements, and FC Fastwrite ports were reset. Recommended Action No - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 196
that back-end (non-user) ports have not come online within the time limit. Recommended Action Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 197
that the slot has completed initializing the Fibre Channel (FC) ports. Recommended Action No action is blade with legacy mode (EX_port having stag) will be disabled. Recommended Action Disable all EX_Ports and VEX_Ports and execute the slotPowerOff or slotPowerOn commands on the 8 Gbps blade - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 198
Self-Test (POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. Additional blade fault messages precede and follow this error, providing more - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 199
the blade does not support dynamic area mode on the default switch. Recommended Action Turn off the dynamic area mode using the configure command. computed value, or there is problem accessing the data. Recommended Action Reseat the SFP transceiver. If problem persists, replace the SFP - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 200
the interop mode is turned on in the default switch while powering on the FCoE blade. Recommended Action Disable the interop mode using the interopmode command; then execute the slotPowerOff and slotPowerOn commands on the FCoE blade. BL-1049 Message Serdestunemode: . Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 201
OS v7.0.0 is incompatible on the Brocade 7800 switch. Recommended Action Contact your switch service provider for upgrade instructions. BL-1052 Message Link Reset threshold exceeded in the internal port (slot , port ). No core blade has been faulted because it has - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 202
CRITICAL Probable Cause Indicates that a Federal Information Protection Standard (FIPS) failure has occurred and requires faulting the blade or switch. Recommended Action Retry the command. BLS-1002 Message An IPsec/IKE policy was added. Message Type AUDIT | LOG Class CFG Severity INFO - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 203
configured tunnel ID (0-7)>). Message Type LOG Severity INFO Probable Cause Indicates that the Fabric OS version on the remote end of the tunnel does not support Tape Read Pipelining. Recommended Action No action is required. BLS-1005 Message S,P( - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 204
firmware download is supported between the revisions. Because the AP and CP blades cannot communicate, it is not possible to load new firmware on the AP blade. If necessary, send the AP blade back to the factory for a firmware update. BM-1002 Message Connection established between CP and blade - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 205
from the control processor (CP) firmware due to a firmware upgrade. • The blade was recently inserted and had a different version of the firmware loaded. Recommended Action No action is required. The blade will automatically download the updated firmware. BM-1005 Message Firmwaredownload timed - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 206
version. Recommended Action Execute the firmwareDownload command to recover the blade. BM-1009 Message Firmwaredownload timed-out for application processor. Faulting switch. Message Type LOG Severity WARNING Probable Cause Indicates that the firmware download on the application processor (AP - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 207
from the control processor (CP) firmware due to a firmware upgrade. • The blade was recently inserted and had a different version of the firmware loaded. Recommended Action No action is required. The blade will automatically download the updated firmware. Fabric OS Message Reference 185 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 208
Cause Indicates that firmware download on the application processor (AP) blade has failed. Recommended Action Execute the slotPowerOff and slotPowerOn commands or reseat the affected blade. BM-1056 Message AP is not configured. Persistently disabling all ports on the switch. Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 209
is valid for the configuration. Message Type LOG commands on the blade. To recover a non-bladed system, execute the fastBoot command on the switch. C2-1004 Message S,C: Invalid DMA ch pointer, chan:, good_addr:0x bad_addr:0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 210
. There is no action required by the user at this time. If any actual hardware blade port number>): best effort QoS will be turned off at next port state change as it is not supported under this configuration Message Type LOG Severity WARNING Probable Cause Indicates that quality of service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 211
blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C2-1012 Message S,P( - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 212
that one or more credits are lost and the link is reset. Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C2-1015 Message Port re-initialized due to Link - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 213
internal trunk. Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C2-1018 Message Link reset threshold value exceeded in the link S,P - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 214
(R_RDY) frames. Recommended Action When this error is observed persistently, replace the device. C2-1026 Message S,P(): Faulting F_port due to extra credit detected:ftx= curr_cred= actual_cred=. Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 215
Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C2-1028 Message Detected excessive Link resets on the port in a second. Slot , Port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 216
is valid for the configuration. Message Type LOG commands on the blade. To recover a non-bladed system, execute the fastBoot command on the switch. C3-1004 Message S,C: Invalid DMA ch pointer, chan:, good_addr:0x bad_addr:0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 217
Message S,P(): best effort QoS will be turned off at next port state change as it is not supported under this configuration. Message Type LOG Severity WARNING Probable Cause Indicates that quality of service (QoS) will be turned off automatically - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 218
persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C3-1011 Message Detected a complete loss of credit on internal back-end VC: Slot , Port () vc_no= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 219
that one or more credits were lost and the link is reset. Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. Fabric OS Message Reference 197 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 220
the specified port is re-initialized due to link reset failure. Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C3-1016 Message Port is faulted due to port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 221
that the specified blade is faulted because the link reset threshold value has exceeded. Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C3-1019 Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 222
Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C3-1025 Message S,P(): Extra credit on F_port:ftx= curr_cred= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 223
Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C3-1028 Message Detected excessive Link resets on the port in a second. Slot , Port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 224
Message Switch offline requested by remote domain . Message Type LOG Severity INFO Probable Cause Indicates that the specified remote domain requested the local domain to be disabled. Recommended Action Check the error message log on the remote domain using the errShow command to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 225
ERROR Probable Cause Indicates that the initialization of a module within the Converged Enhanced Ethernet (CEE) configuration management daemon has failed. Recommended Action Download a new firmware version using the firmwareDownload command. CCFG-1002 Message Started loading CEE system - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 226
has failed. Recommended Action Execute the copy file startup-config command to restore the startup configuration file from any backup retrieved on the server. CCFG-1005 Message Startup configuration file is updated. Message Type LOG Severity INFO Probable Cause Indicates that the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 227
No action is required. CCFG-1010 Message Current system running configuration file is updated partially. Message Type LOG Severity INFO Probable Cause Indicates that the current running configuration file has been updated partially. Recommended Action No action is required. Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 228
line card is different from the pre-configured line card on the specified slot. Recommended Action Execute the no linecard command to remove the line card configuration. CCFG-1012 Message Blade the slotPowerOff and slotPowerOn commands on the specified slot to bring the blade online. CCFG-1013 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 229
slotPowerOff and slotPowerOn commands on the blade. To recover a non-bladed system, execute the fastBoot command on the switch. CDR-1003 Message S,C: HW ASIC Chip error type = 0x. If the problem persists, blade may need to be reset or replaced. Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 230
chan:, good_addr:0x bad_addr:0x. problem persists, replace the blade. CDR-1005 Message S,P(): best effort QoS will be turned off at next port state change as it is not supported under this configuration - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 231
CDR-1007 5 CDR-1007 Message S,C: Internal link errors have been reported, no hardware faults identified, continuing to monitor for errors: flt1:0x, flt2:0x thresh1:0x. Message Type LOG Severity WARNING Probable Cause Indicates - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 232
blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. CDR-1011 Message S,P( - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 233
that one or more credits were lost and the link is reset. Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. CDR-1015 Message Port re-initialized due to Link - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 234
error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. CDR-1018 Message Blade in Slot faulted due to Link reset threshold value exceeded. Message Type LOG Severity ERROR Probable - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 235
Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. CDR-1028 Message Detected excessive Link resets on the port in a second. Slot , Port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 236
inconsistent during failover or recovery. Recommended Action For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade. For a non-bladed switch, restart or power cycle the switch. CHS-1004 Message Blade attach failed during recovery, disabling slot = - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 237
Indicates that the diagnostic blade attach operation has failed during failover or recovery. Recommended Action For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade. For a non-bladed switch, restart or power cycle the switch. Fabric OS Message Reference - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 238
Probable Cause Indicates that the initialization of a module within the Cluster Node Manager (CNM) has failed. Recommended Action Download a new firmware version using the firmwareDownload command. CNM-1003 Message Crypto device cfg between local switch () and peer ( - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 239
INFO Probable Cause Indicates that the crypto service is enabled or disabled on the switch. Recommended Action No action is required. Posting event CNM_EVT_NODE_JOIN nodeName [], WWN [], ipaddress []. Message Type LOG Severity INFO Probable Cause Indicates that the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 240
is required. CNM-1010 Message Posting event CNM_EVT_CLUSTER_UDATA_UPDATE cid [], ulen []. Message Type LOG Severity INFO Probable Cause Indicates the client data update. Recommended Action No action is required. 218 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 241
CNM-1011 5 CNM-1011 Message Posting event CNM_EVT_NODE_JOIN_TIMEOUT nodeName [], WWN [], ipaddress []. Message Type LOG Severity INFO Probable Cause Indicates the node join timeout. Recommended Action Take the peer node offline, and rejoin the node to Encryption Group - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 242
(EG) degrade condition. Recommended Action No action is required. CNM-1017 Message Got JOIN REQUEST from un-recognized GL node [], configured GL node is []. Message Type LOG Severity INFO Probable Cause Indicates a join request was received from an invalid group leader (GL - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 243
CNM-1018 5 CNM-1018 Message Got CNM_FSM_EVT_JOIN_REQ when already a member, My assigned name [], dropping request. Message Type LOG Severity INFO Probable Cause Indicates the node is already a member of the Encryption Group (EG). Recommended Action No action is required. CNM-1019 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 244
5 CNM-1021 CNM-1021 Message Failed to sign the node authentication message, admission control might fail. Message Type LOG Severity INFO Probable Cause Indicates that node admission control has failed. Recommended Action No action is required. CNM-1022 Message Operation not allowed on GL - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 245
0x Node . Message Type LOG Severity INFO Probable Cause Indicates that a version mismatch has occurred. Recommended Action Upgrade the firmware or delete the node from the Encryption Group (EG). CNM-1027 Message Received HBT from non-Group Member Node [ - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 246
5 CNM-1028 CNM-1028 Message Certfile already exists. No need to sync up. Message Type LOG Severity INFO Probable Cause Indicates that the certificate file for the node already exists. Recommended Action No action is required. CNM-1029 Message Certfile - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 247
CNM-1032 5 Recommended Action No action is required. CNM-1032 Message Certfile size does not match cert file size sent by GL. Message Type LOG Severity WARNING Probable Cause Indicates that there is a size mismatch between a node's certificate - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 248
5 CNM-1035 CNM-1035 Message Cluster is in degraded state. Posting degrade event. Message Type LOG Severity WARNING Probable Cause Indicates an event is being posted to specify the cluster is in a degraded state. Recommended Action No action is required. CNM-1036 Message All the active nodes - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 249
is won. Recommended Action No action is required. CNM-1041 Message Updating persistent Cluster DB, please avoid powering off the switch. Message Type LOG Severity INFO Probable Cause Indicates the system is updating the persistent database. Fabric OS Message Reference 227 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 250
update is complete. Recommended Action No action is required. CNM-1043 Message Received HBT from undefined node IpAddress [], WWN []. Possible configuration is not invoked. Recommended Action Execute the cryptocfg --initnode command. 228 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 251
node has decided to leave the Encryption Group (EG). Recommended Action No action is required. CNM-1047 Message Network Interface to Remote Node [] is []. Message Type LOG Severity INFO Probable Cause Indicates that the status of the network interface is up or down. Recommended - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 252
Rejected by GL Node due to Access Gateway Daemon mode mismatch, ensure mode settings are same across all nodes in EG. Message Type LOG Severity ERROR Probable Cause Indicates mode mismatch between the switches, such as the Access Gateway mode mismatch. Recommended Action No action is required - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 253
Recommended Action Eject the specified node from EG and retry the operation. CNM-1054 Message Encryption Group database state [] with node IP [], WWN []. Message Type LOG Severity INFO Probable Cause Indicates the status of the cluster database. Recommended Action No action - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 254
the Encryption Group (EG). Recommended Action No action is required. CNM-1057 Message Posting event CNM_EVT_ONLINE Slot [], WWN [], IP [], flags []. Message Type LOG Severity INFO Probable Cause Indicates that the encryption engine is online in the Encryption Group (EG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 255
pair is matched. Recommended Action No action is required. CNM-1061 Message IP of the switch changed from [] to []. Message Type LOG Severity INFO Probable Cause Indicates that the switch IP address has changed. Fabric OS Message Reference 233 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 256
. Message Type LOG Severity INFO Probable Cause Indicates that the certificate was copied to the file with new IP name. Recommended Action No action is required. CNM-3001 Message Event: cryptocfg Status: success, Info: encryption group \"\" created. Message Type AUDIT - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 257
CNM-3003 5 CNM-3003 Message Event: cryptocfg Status: success, Info: Membernode \"\" added to encryption group. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the specified member node was added to an encryption group. Recommended Action - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 258
: cryptocfg Status: success, Info: Routing mode of EE in slot set to . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the encryption engine routing mode was set. Recommended Action No action is required. 236 Fabric OS Message Reference - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 259
CNM-3009 5 CNM-3009 Message Event: cryptocfg Status: success, Info: registered. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the specified member node was registered. Recommended Action No action is required. CNM-3010 Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 260
5 CNM-3012 CNM-3012 Message Deleteing an EG with LUNs setup for encryption can lead to LUNs being disabled if Encryption Group name is (EG) was deleted. Recreate EG with the same name if LUNs are set up for encryption. Recommended Action Preserve the EG name when EG is recreated if LUNs are - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 261
AD variable is the description of the classes of configuration parameters that were downloaded. If Admin Domain (AD) is enabled, the AD number is Recommended Action Execute the errShow command to view the error log. Correct the error and execute the configDownload command again. Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 262
was unsuccessful because there are one or more parameters that require the switch to be disabled. Recommended Action Disable the switch using the switchDisable command and download the configuration. CONF-1023 Message configDownload failed . Message Type LOG Severity INFO Probable - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 263
Cause Indicates that the previous configuration commands have resulted in a database full condition.Configuration changes associated with the specified key was not applied. Recommended Action Use configure command and various other commands to erase configuration parameters that are no longer - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 264
-1032 CONF-1032 Message configRemove completed successfully . Message Type LOG Severity INFO Probable Cause Indicates that the configRemove command was initiated and completed successfully. Recommended Action No action is required. CONF-1040 Message configDefault Failed. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 265
> changed from to Message Type LOG | AUDIT Class CFG Severity INFO Probable Cause Indicates that the fabric configuration parameter value has been changed by a user. Recommended Action No action is required. Fabric OS Message Reference 243 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 266
5 CTAP-1001 CTAP Messages CTAP-1001 Message Key acquisition for . Message Type LOG Severity INFO Probable Cause Indicates that a change in the tape pool database has triggered the key acquisition process for each pool. Recommended Action Do not start - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 267
LUN ID: . Message Type LOG Severity INFO Probable Cause Indicates that the first-time encryption, key expired, or manual re-key operation is performed. The operation has been started, completed, failed, or cancelled. Recommended Action No action is required. CVLC-1002 Message Tape - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 268
5 CVLC-1004 CVLC-1004 Message Forceful encryption LUN removal while re-key session is still active. Container: , Initiator: , LUN ID: . Message Type LOG Severity INFO Probable Cause Indicates that the encryption LUN was forcefully removed - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 269
decryption of existing data is still enabled. Recommended Action To preserve the user data, execute the cryptocfg --modify -LUN -cleartext command to convert to cleartext LUN. Use the cryptocfg --modify -LUN -cleartext command to disable decryption of existing data. Then try to delete the LUN - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 270
: . Message Type LOG Severity ERROR Probable Cause Indicates that the encryption LUN is configured with non-Brocade mode but there is no valid license. Recommended Action Obtain a license for non-Brocade mode. CVLC-1012 Message Disk metadata is in wrong format ( - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 271
CVLC-1014 Message Missing Key ID from user input. Container: , that the data state in the LUN configuration is in the encrypted state without a command to add the key ID, if available. CVLC-1015 Message LUN is set to read only mode. Reason: - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 272
container name>, Initiator: , LUN ID: . Message Type LOG Severity INFO Probable Cause Indicates that the LUN is set to read/write mode. Recommended Action No action is required. CVLC-1017 Message Event: . Container: - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 273
exists on the LUN that is in cleartext state. Recommended Action Use the cryptoCfg command to confirm the configuration. CVLC-1021 Message User provided key ID is ignored while metadata exists. Container: , Initiator - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 274
provided key ID is ignored while data state is clear text. Container: , to container configuration changes, weights are not balanced on OB1s. Recommended Action Run the cryptocfg --rebalance command to increase system performance. CVLC-1024 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 275
exists on the LUN that is not configured with the -newLUN option. Recommended Action Use the cryptoCfg command to remove and add the LUN secondary metadata does not exist on all logical block addresses (LBAs) for a LUN that is configured with the -newLUN option. Recommended Action No action - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 276
name>, Initiator: , LUN ID: . Message Type LOG Severity WARNING Probable Cause Indicates a warning event. Recommended Action Perform a manual re-key on this LUN. CVLC-1029 Message Mirror LUN is disabled as primary LUN is being rekeyed without splitting the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 277
action is required. CVLC-1033 Message Rebalance completed for EE: . Device login in progress. Message Type LOG Severity INFO Probable Cause Indicates that a rebalance operation was performed. Recommended Action No action is required. Fabric OS Message Reference 255 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 278
Cause Indicates that the first-time encryption, key expired, or manual re-key operation failed. Recommended Action No action is required. that a decommissioned LUN has been added as an encrypted LUN. Recommended Action Perform the following steps. 1. Remove the LUN from the container. 2. Add the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 279
CVLC-1041 5 CVLC-1041 Message . Container: , Initiator: , LUN ID: . Message Type LOG Severity WARNING Probable Cause Indicates that the host write operation on secondary metadata block region - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 280
that the initialization of a module within the Crypto Virtual LUN Manager (CVLM) daemon has failed. Recommended Action Download a new firmware version using the firmwareDownload command. CVLM-1003 Message Crypto device configuration has been committed by switch (). Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 281
configurations. Recommended Action Synchronize the configuration in the cluster group using the cryptocfg --commit command. CVLM-1005 Message Crypto service is on the switch Use the ad command to move the crypto device into AD0. CVLM-1007 Message Redirect zone update failure. Status is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 282
the inter-switch link (ISL) port connected to the configured. Message Type LOG Severity WARNING Probable Cause Indicates that the IP address of the encryption engine IO link is not configured. Recommended Action Configure the encryption engine IO link IP address using the ipAddrSet command - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 283
Cause Indicates that creation of the redirect zone has failed. Recommended Action Create the Layer 2 zone for host and target and run the cryptocfg --commit command again. Fabric OS Message Reference 261 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 284
but IT pair is in crypto configuration. Recommended Action Disable the target access to the host, recreate the Layer 2 zone for host and target, and run the cryptocfg --commit command again to recreate the RD zone. CVLM-1015 Message Unable to read basewwn from blade in slot . Message Type - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 285
to . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the failback mode was set. Recommended Action No action is required. CVLM-3002 Message Event: cryptocfg Status: success, Info: HA cluster \"\" created. Message Type AUDIT - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 286
5 CVLM-3004 CVLM-3004 Message Event: cryptocfg Status: success, Info: Cluster member added to HA cluster \"\". Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that an HA cluster member was added. Recommended Action No action is required. CVLM- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 287
>/ to EE /. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that a manual failback was performed to an encryption engine. Recommended Action No action is required. Fabric OS Message Reference 265 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 288
5 CVLM-3010 CVLM-3010 Message Event: cryptocfg Status: success, Info: Move crypto target container \"\" to EE /. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the specified crypto-target container was moved to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 289
CVLM-3013 5 CVLM-3013 Message Event: cryptocfg Status: success, Info: LUN , attached through Initiator \"\", added to crypto target container \"\". Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that a LUN was added - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 290
5 CVLM-3016 CVLM-3016 Message Event: cryptocfg Status: success, Info: LUN , attached through Initiator \"\" in crypto target container \"\", enabled. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the specified - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 291
\"\" in crypto tgt container \"\". Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that a manual re-key of a LUN was performed. Recommended Action No action is required. CVLM-3021 Message Event: cryptocfg Status: success, Info - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 292
container \"\". Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that a resume re-key was performed. Recommended Action No action is required. CVLM-3023 Message Event: cryptocfg Status: success, Info: Transaction committed. Message Type - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 293
Probable Cause Indicates that the decommission operation has failed for the device. Recommended Action Run the cryptocfg --decommission command. CVLM-3027 Message Event: cryptocfg Status: success, Info: Decommission of device (container , initiator , LUN - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 294
CVLM-3028 Message Event: cryptocfg Status: success, Info: SRDF mode set to . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the Symmetrix Remote Data Facility (SRDF) mode was set. Recommended Action No action is required. 272 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 295
DOT1 Messages DOT1-1001 Message 802.1X is enabled globally. Message Type LOG Severity INFO Probable Cause Indicates that 802.1X is enabled globally. Recommended Action No action is required. DOT1-1002 Message 802.1X is disabled globally. Message Type LOG Severity INFO Probable Cause - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 296
been unauthorized forcefully using the dot1x port-control force-unauthorized command. Recommended Action No action is required. DOT1-1005 authentication dial-in user service (RADIUS) server is not functioning properly. Recommended Action Check the credentials configured with the supplicant - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 297
CRITICAL Probable Cause Indicates that there is no remote authentication dial-in user service (RADIUS) server available for authentication. Recommended Action Execute the aaaConfig --show command to verify that the configured RADIUS servers are reachable and functioning. DOT1-1008 Message Port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 298
5 DOT1-1010 DOT1-1010 Message Port is set in auto mode. Message Type LOG Severity INFO Probable Cause Indicates that the specified port is set to auto mode. Recommended Action No action is required. 276 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 299
Single bit errors are corrected, but other errors indicate either software errors or problems with the target system DRAM. Single bit errors can be expected to occur errors and all other error types should be reported to technical support for further action. ECC-1001 Message ECC Error - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 300
POST) is enabled; then power cycle the blade by using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. For the Brocade 300 and 6510, replace the switch. 278 Fabric OS Message Reference 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 301
range of the switch. Execute the fanShow command to verify fans are operating properly. Make sure there are no blockages of the airflow around the chassis. If the temperature problem is isolated to the blade itself, replace the blade. Voltage problems on a blade are likely a hardware problem on the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 302
blade is incompatible, upgrade the firmware or replace the blade and make sure the replacement blade is compatible with your control processor (CP) type and firmware. If the incompatibility is with the logical switch configuration, change the configuration by using the lscfg command problem persists - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 303
by using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. If the problem still persists, replace the FRU. EM-1013 Message Failed to update FRU information for . Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 304
was discovered when performing consistency checks during a cold boot. Recommended Action Monitor the switch. If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 282 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 305
WARNING Probable Cause Indicates that a user did not commit a changed World Wide Name (WWN) value before performing a system restart, power cycle, or firmware download operation. Recommended Action Change and commit the new WWN value. EM-1018 Message CP blade in slot failed - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 306
switch service, which is not enabled. The blade is faulted. Recommended Action Execute the fosconfig --enable ethsw command to enable the Ethernet switch service. Note that this is a disruptive command area on the main logic board. The problems were encountered when the software attempted to write - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 307
the problem has been resolved. If the problem persists, check for loose or dirty connections. Remove Manual for instructions on inserting the switch blades. EM-1033 Message CP in set wait for the error to clear (execute the slotShow command to determine if it has cleared). Watch for the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 308
Name (WWN) card, the default WWN and IP addresses are used for the switch. Recommended Action Reseat the FRU. If the problem persists, restart or power cycle the switch. Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power cycle the blade by using the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 309
database, which contains information about all FRUs. Recommended Action Reseat the FRU. If the problem persists, replace the FRU. EM-1043 Message Can't power - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 310
on because the associated logical switch is shutdown. Recommended Action Execute the switchStart command on the associated logical switch. EM-1045 Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 311
supported on that chassis (backplane revision D2). Remove the blade from the chassis. If the error is due to the switch configuration, the logical switch configuration of the blade is incorrect. Execute the lscfg command to correct the switch or port configuration I2C) bus problems have been resolved - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 312
circuit (ASIC) parity error. Recommended Action No action is required if the switch does not reach the reset threshold for the switch or blade. If the reset threshold is reached on the switch or blade, the switch or blade will be faulted and should be replaced. 290 Fabric OS Message Reference - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 313
reach the reset threshold for the switch or blade. If the reset threshold is reached on the switch or blade, the switch or blade will be faulted and should be replaced. EM-1059 Message with ID may not be supported on this platform, check FOS firmware version as - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 314
that the blade in the system is not supported by the firmware on the standby control processor (CP). Recommended Action Remove all blades of the specified type or upgrade the standby CP. After an appropriate action is taken, restart the standby CP or execute the haSyncStart command to enable - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 315
the control processor firmware (CFOS) or the blade processor firmware (BFOS) is not compatible with the Storage Application Services (SAS) or other application firmware versions. Recommended Action Upgrade the Fabric OS firmware or the SAS firmware by using the firmwareDownload command. Refer to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 316
Fabric OS configuration or hardware problems on the switch. Recommended Action Restart or power cycle the switch. If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 317
, faulted, or powered off. There must be at least one core blade in enabled state for the chassis to be considered ready. Recommended Action Insert and close the ejector switch on missing core blades. Reseat or replace core blades that are faulted or powered off. Fabric OS Message Reference 295 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 318
the root level. The ID will be Switch for non-bladed systems. Recommended Action On bladed systems, reseat the specified FRU. On non-bladed switches, restart or power cycle the switch. If the problem persists, perform the following actions: • Execute the diagPost command to make sure that Power-On - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 319
Action Discontinue the firmware download, identify the down-level switch or switches that do not support the Coordinated HotCode protocol, and upgrade the down-level switches. Then, restart the firmware download on this switch. Note that upgrading a down-level Brocade switch in a mixed interop - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 320
Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric did not accept the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to this issue. Recommended Action No - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 321
an appropriate fabric name and set it again from any switch. ESS-1010 Message Duplicate Fabric Name - matching with FID . Message Type AUDIT | LOG Class FABRIC Severity WARNING Probable Cause Indicates that the configured - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 322
the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade. For a non-bladed switch, restart or power cycle the switch. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 323
Action For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade. For a non-bladed switch, restart or power cycle the switch. ESW-1006 Message HA state out of sync: Standby CP (ver = ) does not support NPIV functionality. (active - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 324
the switch distance or speed settings for the port blade is enabled with the port configuration that already has the area swapped. Recommended Action Replace the blade with ports that support port swap. Then swap ports back to the port's default area. Refer to the Fabric OS Administrator's Guide - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 325
Message Type LOG Severity WARNING Probable Cause Indicates that the event could not be sent to remote proxy. This could happen if the remote proxy switch cannot be reached through in-band. Recommended Action Make sure that the specified remote domain is present in the fabric. Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 326
with the message, look for a possible mismatch of relevant configuration parameters in the switches at both ends of the link. Run the configure command to modify the appropriate switch parameters on both the local and remote switch. FABR-1002 Message fabGaid: no free multicast alias IDs. Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 327
due to problems with the kernel, the system will recover by performing a failover. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. FABR-1005 Message : port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 328
performing an automatic failover. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service the problem is usually transitory. Otherwise, this message is rare and usually indicates a problem with - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 329
message is rare and usually indicates a problem with the Fabric OS. Recommended Action If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Fabric OS Message Reference 307 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 330
message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. FABR-1013 Message No Memory: pid= file= line=. Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 331
configure command to change the insistent domain ID mode. Refer to the Fabric OS Command Reference for more information on these commands. FABR-1016 Message ficonMode is enabled. Message Type LOG Severity WARNING Probable Cause Indicates that FICON mode is enabled on the switch through a user - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 332
command. FABR-1019 Message Critical fabric size () exceeds supported configuration (). Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that this switch is a value-line switch Indicates that this switch has a value-line license and has a - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 333
Severity CRITICAL Probable Cause Indicates that this switch has a value-line license and has a limited number of domains. licensed limit. Contact your switch provider to obtain a full fabric license. FABR-1022 Message Fabric size () exceeds supported configuration ( - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 334
has exceeded the limit set by your value-line switches. Value-line switches have a limited end of the link. The flow control is a mechanism of throttling the transmitter port to avoid buffer overrun at the receiving port. There are three types of flow control modes: • VC_RDY mode: Virtual-channel - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 335
E_Port. Recommended Action Run the top command to see if iswitchd is extremely busy or if another process is using excessive CPU resources. FABR-1032 Message Remote switch with domain ID and switchname running an unsupported FOS version v2.x has joined the fabric - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 336
must manually enable the port or the port remains disabled forever. Refer to the Fabric OS Administrator's Guide for on a switch is Trunk Area-enabled, it does not allow other devices like Access Gateway (AG) or the switch finds the Trunk Area enabled is incompatible with port configurations such - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 337
disabled because F_Port trunking is enabled without a trunking license being present. Recommended Action Install a trunking license or disable F_Port trunking on the port. FABR-1039 Message Invalid domain ID zero received from principal switch(domain id=). Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 338
port may recover by re-initialization of the link. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. FABR-1043 Message Detected Fabric ID conflict with remote (not neighbor - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 339
that the remote switch has a Base Switch attribute conflict with the local switch. All the E_Ports directly connected to the conflicting switch are disabled. Recommended Action Make sure that all the switches in the fabric have the same Base Switch attribute or upgrade the switch firmware to a VF - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 340
FID of the local switch. All E_Ports directly connected to the conflicting switch are disabled. Recommended Action Make sure that all the switches in the fabric have the same FID or upgrade the switch firmware to a VF-capable firmware. FABR-1050 Message license not present. F_Port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 341
, cables, or blade. FABR-1052 Message The configured port speed (16G/10G on non FC16 blade or 1G on FC16 blade) is invalid. configuration keys have interopmode parameters such as switch.interopMode and switch.mcdtFabricmode set. Recommended Action Execute the interopmode command to reset - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 342
operation is still in progress and the standby CP has received a port update. The standby CP reboots automatically to ensure sync and attain the normal state F_Port and the portcfgshow command to identify the conflicting configuration between the trunk members. 320 Fabric OS Message Reference - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 343
. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. FABS-1004 Message process () . Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 344
media state to blade driver Recommended Action If the message is isolated, monitor the error messages on the switch. If the error is repetitive or if the fabric failed, failover or reboot the switch. If the message persists, run the firmwareDownload command to update the firmware. 322 Fabric OS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 345
an object status field. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. FABS-1008 Message : Media oid mapping failed. Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 346
problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware firmwareDownload command to update the firmware. FABS-1013 Message []:Unknown blade type 0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 347
FRU could not be enabled. This is usually an internal Fabric OS problem. Recommended Action Remove and reinsert the FRU. Reboot or power cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. Fabric OS Message Reference 325 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 348
command. Refer to the release notes to determine whether a non-disruptive firmware download is supported between the revisions. Because the AP and CP blades cannot communicate, it is not possible to load new firmware on the AP blade. If necessary, send the AP blade back to the factory for a firmware - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 349
is low on memory and failed to allocate new memory for an information unit (IU). Recommended Action A non-bladed switch will automatically reboot. For a bladed switch, the active CP blade will automatically fail over and the standby CP will become the active CP. Fabric OS Message Reference 327 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 350
failure. Recommended Action Check the memory usage on the switch using the memShow command. FCOE-1002 Message Max logingroup limit reached at . Message Type LOG Severity WARNING Probable Cause Indicates that too many login groups have been added. Recommended Action Check the maximum - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 351
LOG Severity ERROR Probable Cause Indicates that removing a device from the login group has failed. Recommended Action Execute the supportSave command and restart the system. If the problem persists, contact your switch service provider. FCOE-1005 Message : membership check failed in - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 352
(FSS) registration or initialization of the FCoE trace has failed. Recommended Action Execute the supportSave command and restart the system. If the problem persists, contact your switch service provider. FCOE-1012 Message Request to delete port from VLAN failed. Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 353
Recommended Action Execute the supportSave command and restart the system. If the problem persists, contact your switch service provider. FCOE-1015 Message in use. Recommended Action Disable the active FCoE login session using the no fcoe command and try deleting the VLAN again. FCOE-1017 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 354
has not been configured on FCoE VLAN. Recommended Action Configure FCMAP on the FCoE VLAN using the fcoe --fcmapset command. FCOE-1021 Message 1022 Message Max FCoE device login limit reached. Message Type LOG Severity WARNING Probable Cause Indicates that the switch has reached its maximum - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 355
that a FDISC frame is received from the end node that has not logged in. The end node must send a fabric login (FLOGI) before it can send an FDISC. Recommended Action It is due to a CNA or target driver issue. Contact CNA or target driver support team for assistance. FCOE-1025 Message FCoE - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 356
Probable Cause Indicates that the Fibre Channel Forwarders (FCF) controller is not found for the DA. The end node may be sending the FLOGI with a wrong DA MAC address. Recommended Action Some parameters are not exchanged correctly between the switch and the end device. Reconfigure the port. FCOE - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 357
logout and the base fabric login (FLOGI). Recommended Action It is due to a CNA or target driver issue. Contact CNA or target driver support team for assistance. FCOE-1031 that high availability (HA) failover or switch reboot may be in progress. Fabric OS Message Reference 335 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 358
Action Wait until the chassis has fully recovered before you perform any operations. FCOE-1033 Message FIP v1 FLOGI received - priority using the fabric-map default command under the FCoE configuration mode. FCOE-1037 Message Logingroup dropped for switch WWN: , due to name - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 359
that the specified login group is deleted from the switch login group table. Recommended login group has been renamed. Recommended Action No action is required. FCOE-1041 Message Transaction aborted. Message Type LOG Severity INFO Probable Cause Indicates that the ongoing FCoE login configuration - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 360
is disabled. Recommended Action No action is required. FCOE-1044 Message FCoE login configuration management enabled. Message Type LOG Severity INFO Probable Cause Indicates that the FCoE login configuration management is enabled. Recommended Action No action is required. 338 Fabric OS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 361
in the fcoed.conf file does not match. Therefore, the fcoed.conf file is truncated and updated with a new magic number. Recommended Action Reconfigure the FCoE ports as all the port configurations will be lost. FCOE-1047 Message fcoed.conf file is not present, therefore creating. Message Type - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 362
5 FCOE-1048 Recommended Action No action is required. 340 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 363
that a Fibre Channel Protocol (FCP) switch probed devices on a loop port, and probing failed on the L_Port, arbitrated loop physical address (AL_PA), or Action Contact the device vendor for any firmware-related issues. Also, consider upgrading the device firmware. FCPD-1002 Message port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 364
5 FCPD-1003 Recommended Action The Brocade 4100, 4900, 5000, 7500, and AP 7600 do not support private loop devices. Refer to the switch vendor for a list of other port types that support private devices for inclusion into the fabric. 342 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 365
creates a Fibre Channel driver instance. The failed function call can only be kmalloc_wrapper, which has failed. This function call is for kernel memory allocation. Recommended Action A non-bladed switch will automatically reboot. For a bladed switch, the active CP blade will automatically - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 366
Cause Indicates that the specified N_Port ID virtualization (NPIV) port has the same Port World Wide Name WARNING Probable Cause Indicates that in busy login conditions, the buffer used for quick memory Recommended Action Reset the specified port using the portDisable and portEnable commands. 344 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 367
proxy device at a port in the edge fabric has been imported at the specified port. Recommended Action No action is required. FCR-1002 Message FC router proxy device in edge deleted at port . Message Type LOG Severity INFO Probable Cause Indicates that a proxy device at a port in - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 368
all small form-factor pluggables (SFPs) are seated correctly. Check for faulty cables, deteriorated SFPs, or dirty connections. Replace the cables and the SFPs if necessary. FCR-1005 Message FC router LSAN zone device removed at port . Message Type LOG Severity INFO Probable Cause - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 369
network (LSAN) zone attached to the specified port was deleted in the edge fabric. Recommended Action No action is required. FCR-1008 Message FC router LSAN zone created at port . Message Type LOG Severity INFO Probable Cause Indicates that a logical storage area network (LSAN - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 370
area network (LSAN) zone update was received from another domain. Recommended Action No action is required. FCR-1012 Message FC Router fabric build completed on port . Message Type LOG Severity INFO Probable Cause Indicates that the Fibre Channel router has completed a fabric - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 371
>. Message Type LOG Severity INFO Probable Cause Indicates that a fabric is no longer accessible through the backbone fabric. This may be caused by a link or switch failure. Recommended Action No action is required. Fabric OS Message Reference 349 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 372
port resource problem. LSAN zones are removed using standard zoning commands such as perform the following steps: 1. Use the portDdisable command to disable all the EX_Ports that received this error message. 2. Use the portDdisable command to disable all the other EX_Ports on that FCR connected - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 373
Recommended Action Remove the proxy device slots by using the fcrProxyConfig command or limit proxy devices by removing logical storage area network ( the number of port WWNs required by limiting the remote edge fabric connectivity (which limits the number of translate domains). You can also limit - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 374
the number of node WWNs required by limiting the remote edge fabric connectivity (which limits the number of translate domains). FCR-1026 Message In that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with a large number of - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 375
that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with a large number of or there are highly dynamic changes to EX_Port or VEX_Port connectivity. WWN conflicts might cause unpredictable behavior in management applications - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 376
5 FCR-1030 FCR-1030 Message Physical device came online at fabric . Message Type LOG Severity INFO Probable Cause Indicates that the physical device World Wide Name (WWN) came online in the specified fabric. Recommended Action No action is required. FCR-1031 Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 377
LOG Severity INFO Probable Cause Indicates that the specified logical storage area network (LSAN) zone was enabled in the backbone fabric. The enabled LSAN zone configuration is listed. Recommended Action No action is required. Fabric OS Message Reference 355 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 378
Severity WARNING Probable Cause Indicates that the number of cfg, zone, or alias entries created in a local fabric is greater than the local switch's zone database limitations. Recommended Action Remove excess cfg, zone, or alias entries so that the number of logical storage area network (LSAN - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 379
FCR-1040 5 FCR-1040 Message Proxy device deleted in the backbone fabric. Message Type LOG Severity INFO Probable Cause Indicates that a proxy device created in the backbone fabric was deleted. Recommended Action No action is required. FCR-1041 Message LSAN zone device removed in the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 380
the portEnable command. If the problem persists, reboot the switch. If the message persists, collect switch information using the supportSave command, and contact your switch service provider. FCR-1049 Message EX_Port () received an ELP command that is not supported. Message Type - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 381
WARNING Probable Cause Indicates that an internal link service (ILS) IU of invalid size was received from the switch on the other end of the link. Recommended Action Check the error message log on the other switch using the errShow command for additional messages. Check for a faulty cable or - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 382
ID of this port. Recommended Action Check the switches on both ends of the link for a possible mismatch in switch or port configuration parameters such as Operating Mode, E_D_TOV, R_A_TOV, Domain ID Offset, and so on. Run the portCfgExport command to modify the appropriate parameters on the local - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 383
command to verify that the VC Link Init is disabled, if the remote switch is configured in R_RDY mode or only capable of R_RDY mode. • VC_RDY mode: Virtual channel flow control mode. This is a proprietary protocol. • R_RDY mode: Receiver-ready flow control mode. This is the Fibre Channel supports - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 384
does not match the local switch. Recommended Action Run the switchShow command to display the fabric ID. Change the fabric ID to match on both ends by modifying either the local or remote host using the fcrConfigure command. FCR-1064 Message Fabric ID of backbone FC-Routers mismatch or overlap - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 385
configurations created in connected fabric exceeds the maximum number supported by the Fibre Channel. The limit includes both active and configured or the configDownload command with the fcrState set to 2 (disabled). Note that the FC Routing service is disabled by the factory. Recommended Action - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 386
that the FC Routing service is disabled by the factory. Recommended Action No action is required. FCR-1070 Message The FC Routing configuration is set to default. Message Type LOG Severity INFO Probable Cause Indicates that the FC Routing configuration is set to the default by the user. This - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 387
Severity INFO Probable Cause Indicates that an older version switch in the backbone or edge that supports a different limit of logical storage area network (LSAN) zones was detected. Recommended Action Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find lowest - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 388
Cause Indicates that the zone name configuration size created in the connected fabric exceeds the maximum supported by the FC Router. This size is equal was attempted. Recommended Action Ensure that the M-Model switch has the same currently configured details such as the front port domain ID and - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 389
database. FCR-1079 Message Domain has conflict matrix database with local domain. Message Type LOG Severity WARNING switch in the fabric has not responded to the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 390
Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric did not accept the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been the result of this issue. Recommended Action - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 391
switch in the fabric did not accept the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download -based matrix or upgrade the remote CP. FCR-1086 Message HA sync lost as remote CP does not support 8 Gbps-capable FC based EX_Ports - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 392
ERROR Probable Cause Indicates that the EX_Port connects to the logical fabric containing a domain that XISL" mode of the domain by using the configure command. FCR-1088 Message LSAN tag INFO Probable Cause Indicates that the user has removed a LSAN tag. Recommended Action - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 393
LOG Severity ERROR Probable Cause Indicates that the FCR ELS trap entries are exhausted. Recommended Action Execute the supportSave command and contact your switch service provider. FCR-1093 Message Slave EX-Port interopmode conflicts with trunk master . Disabling the port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 394
FCR-1094 Message No Integrated Routing license present. EX-Port will not perform device sharing with other Brocade Native mode fabric(s). Message Type LOG Severity WARNING Probable Cause Indicates that an EX_Port has been configured in Brocade Native mode. Device sharing will not - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 395
using the portDisable and portEnable commands or the switchDisable and switchEnable commands. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Fabric OS Message Reference - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 396
Enabled or Disabled> RdBlkId . Message Type LOG Severity INFO Probable Cause Indicates the configuration was changed manually. Recommended Action No action is required. 374 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 397
Message Type LOG Severity ERROR Probable Cause Indicates a Selective Reset from the channel was received as either a normal part of path recovery channel as a part of path recovery. Recommended Action If there was a job failure associated with this event, contact your vendor's customer support - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 398
was received from a device and a sense command was issued to read the sense data. channel. Recommended Action If there was a job or I/O failure associated with this event, contact your vendor's customer support or device presented a Read Record Set Sequence number different from the SDM - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 399
attached storage device (DASD) Control Unit. Recommended Action If there was a job or I/O failure associated with this event, contact your vendor's customer support for assistance. FICN-1013 Message DevDiskIng:Status=0x received in - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 400
processing components. Recommended Action Contact your vendor's customer support for assistance. FICN-1016 Message DevIng:Received Logical Path Unit sent a Logical Path Removed (LPR) frame to the FICON channel. Recommended Action No action is required. FICN-1017 Message DevIng:Received - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 401
Action Contact your vendor's customer support for assistance. FICN-1019 Message CUADDR DeviceAddr> LastCmd=0x LastStatus=0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 402
ERROR Probable Cause Indicates the FICON channel issued a Selective Reset for a device that was active in emulation. Recommended Action If there was an unexpected job failure associated with this event, contact your vendor's customer support for assistance. FICN-1023 Message DevTapeEgr - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 403
channel issued a Purge Path command support for assistance. FICN-1026 Message DevTapeIng:UnusualStatus:WriteCancelSelr:Generating Final Ending Reset sequence. Recommended Action If there was an unexpected job failure or I/O error associated with this event, contact your vendor's customer support - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 404
's customer support for assistance. FICN-1029 Message HostDiskIng:FICON Selective Reset:Path=0x state=0x LastCmds=0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 405
Message Type LOG Severity WARNING Probable Cause Indicates the FICON channel sent a System Reset to the disk control unit. Recommended Action No action is required. The MVS system was either set to initial program load (IPL) or performing error recovery. FICN-1032 Message HostDiskIng:XRC Read - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 406
customer support for assistance. FICN-1035 Message HostIng:FICON System Reset received on Path=0x**. Message Type LOG Severity WARNING Probable Cause Indicates a locally connected FICON channel issued a System Reset to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 407
>******. Message Type LOG Severity ERROR Probable Cause Indicates a locally connected FICON channel sent a frame that could not be associated with a FICON device. Recommended Action Contact your vendor's customer support for assistance. Fabric OS Message Reference 385 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 408
connected FICON channel sent a frame that could not be associated with a FICON Control Unit. Recommended Action Contact your vendor's customer support LastCmd=0x LastStatus=0x. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 409
customer support for assistance. FICN-1043 Message HostTapeIng::FICON Selective Reset:Path =0x state=0x LastCmds=0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 410
Probable Cause Indicates a Purge Path was received from the locally connected FICON channel. This is performed during the path recovery. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance. FICN-1046 Message HostTapeIng:LRJ received on Path - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 411
vendor's customer support for assistance. FICN-1050 Message ProcessEgrTirData:Lost Logical Path for Path=0x** Index= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 412
DeviceAddr> Message Type LOG Severity INFO Probable Cause Indicates a PSF command has been received to initiate an eXtended Remote Copy (XRC) session If this was an unexpected event, contact your vendor's customer support for assistance. FICN-1053 Message XRC Withdraw From Session: SessID=< - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 413
>. Message Type LOG Severity WARNING Probable Cause Indicates a PSF command has been received to suspend an eXtended Remote Copy (XRC) Action If this was an unexpected event, contact your vendor's customer support for assistance. FICN-1056 Message FICON Emulation Error Error Code= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 414
frame could not be created and sent to a device. Recommended Action This is an unexpected event; contact your vendor's customer support for assistance. FICN-1058 Message Error return from frame generation processing for a FICON control unit: Path=0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 415
LOG Severity ERROR Probable Cause Indicates an abort operation has been received from the local FC interface for an active emulation exchange. Recommended Action This is an unexpected event; contact your vendor's customer support for assistance. Fabric OS Message Reference 393 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 416
a peer FC interface for an active emulation exchange. Recommended Action This is an unexpected event; contact your vendor's customer support for assistance. at the same time as this event, contact your vendor's customer support for assistance. FICN-1065 Message Egress Abort:Oxid=0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 417
Cause Indicates an abort operation has been received from a local FC interface for an emulation CH exchange. Recommended Action If there were I/O errors at the same time as this event, contact your vendor's customer support for assistance. FICN-1068 Message Ingress Abort:Oxid=0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 418
configuration. Refer to the string for the nature of the configuration issue. Recommended Action If resolution of the configuration issue cannot be completed, contact your vendor's customer support device. Recommended Action The end of tape is a normal locally connected Logical Partition - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 419
>:cmds=0x:status=0x:flags I/O has been processed from a locally connected Logical Partition (LPAR) and Tape Write Pipelining was performed on the currently loaded tape. Fabric OS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 420
while this tape was loaded>:Cmds=0x:Chains=0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 421
cmds=0x:status=0x:flags has been processed from a remotely connected Logical Partition (LPAR) and Write Tape Pipelining was performed on the currently loaded tape. Recommended - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 422
been processed from a remotely connected Logical Partition (LPAR) and Read Channel Program pipelining was performed on the currently loaded tape. commands received from the channel for this device> lastStatus=0x treating as system reset - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 423
logged out from the switch. Recommended Action This may be an unexpected event; contact your vendor's customer support for assistance. FICN-1084 access to its address range is prohibited. Recommended Action This is an unexpected event; contact your vendor's customer support for assistance. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 424
ge0 or ge1>,tunnel Id=. Message Type LOG Severity ERROR Probable Cause Indicates a FICON FCIP tunnel to the peer switch has been terminated. Recommended Action This is an unexpected event; contact your vendor's customer support for assistance. FICN-1087 Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 425
Severity ERROR Probable Cause Indicates the FICON channel issued a Selective Reset for a device that was active in emulation. Recommended Action If there was an unexpected job failure associated with this event, contact your vendor's customer support for assistance. Fabric OS Message Reference - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 426
Probable Cause Indicates the FICON channel issued a Selective Reset sequence for a device. channel issued a Purge Path command sequence for a device. Recommended Action If there was an unexpected job failure or I/O error associated with this event, contact your vendor's customer support - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 427
Reset sequence. Recommended Action If there was an unexpected job failure or I/O error associated with this event, contact your vendor's customer support > LastCmds=0x SenseData:Bytes0-0xB=0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 428
last 4 commands received from the channel for this device> LastStatus=0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 429
Probable Cause Indicates a Purge Path was received from the locally connected FICON channel. This is performed during the path recovery. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance. FICN-1102 Message HostTeraIng:LRJ received on Path - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 430
I/O error messages with this event, contact your vendor's customer support for assistance. FICN-1104 Message DevTeraEgr:Device Ready on Path=0x commands received from the channel for this device> lastStatus=0x treating as system reset - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 431
LPAR CUADDR DeviceAddr> LastCmd=0x LastStatus=0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 432
Probable Cause Indicates the FICON channel issued a Selective Reset sequence for a device. channel issued a Purge Path command sequence for a device. Recommended Action If there was an unexpected job failure or I/O error associated with this event, contact your vendor's customer support - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 433
I/O error associated with this event, contact your vendor's customer support for assistance. FICN-1113 Message DevPrintIng:LRJ received on Path commands received from the channel for this device> lastStatus=0x treating as system reset - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 434
your vendor's customer support for assistance. FICN-1116 Message HostPrintEgr:AS Link Level Reject (LRJ) from CU Rx Path=0x LastCmd=0x LastStatus=0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 435
Probable Cause Indicates a Purge Path was received from the locally connected FICON channel. This is performed during FICON path recovery. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance. Fabric OS Message Reference 413 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 436
commands received from the channel for this device> lastStatus=0x treating as system reset Type LOG Severity INFO Probable Cause Indicates the configuration was changed manually. Recommended Action No action is required. 414 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 437
Probable Cause Indicates an abort operation has been received from a local FC interface for an exchange. Recommended Action If there were associated I/O at the same time as this event, contact your vendor's customer support for assistance. FICN-2065 Message Egress Abort:Oxid=0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 438
Indicates an attached port which had a FICON emulated path established has logged out from the switch. Recommended Action This may be an unexpected event; contact your vendor's customer support for assistance. FICN-2083 Message EmulEls:SW_RSCN received on VEPort= Domain=0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 439
Cause Indicates a FICON or Fibre Channel Protocol (FCP) emulation-enabled FCIP tunnel to the peer switch has been terminated. Recommended Action This is an unexpected event; contact your vendor's customer support for assistance. FICN-2087 Message FICON connected 3900 printer discovered Path=0x - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 440
if this is a non-bladed switch, download a new firmware version using the firmwareDownload command. FICU-1003 Message : FICON-CUP License Not Installed: (). Message Type LOG Severity WARNING Probable Cause Indicates that the fibre connectivity control unit port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 441
initialization of a module within the fibre connectivity control unit port (FICON-CUP) daemon failed. Recommended Action Download a new firmware version using the firmwareDownload command. FICU-1006 Message Control Device Allegiance Reset: (Logical Path: 0x:0x). Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 442
may be a transient problem. Recommended Action Check the memory usage on the switch using the memShow command. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. FICU - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 443
FICON Management Server (FMS) mode was not enabled because ports with areas 0xFE or 0xFF are connected to devices. Recommended Action Disable ports with areas 0xFE or 0xFF using the portDisable command. FICU-1011 Message FMS mode has been enabled. Message Type AUDIT | LOG Class CFG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 444
reset to proper size. Message Type LOG Severity WARNING Probable Cause Indicates that the file system is too full to create the host data file at the proper size. Recommended Action Execute the switchStatusShow command Verify the expected FICON port address and port number relationship. For - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 445
FICU-1019 5 FICU-1019 Message Switch has been set offline by LP(). Message Type AUDIT | LOG Class CFG Severity INFO Probable Cause Indicates that the FICON Management Server (FMS) has disabled the switch. Recommended Action No action is required. FICU-1020 Message Port Addrs ( - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 446
on the FICON CUP restrictions, refer to the FICON Administrator's Guide. FICU-1023 Message Detected 48 port blade when FMS mode is enabled. Message Type LOG Severity INFO Probable Cause Indicates presence of 48-port blade ports in the switch. Recommended Action No action is required. For more - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 447
exchange overlapped, pid=. Message Type LOG Severity WARNING Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel driver reuses the exchange, the application will overlap. This happens on a timed-out - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 448
Probable Cause Indicates that the link state update (LSU) size exceeds the value the system can support. Recommended Action Reduce the number of switches in the fabric or reduce the number of redundant inter-switch links (ISLs) between two switches. 426 Fabric OS Message Reference 53-1002749 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 449
FLOD-1005 5 FLOD-1005 Message Invalid received domain ID: . Message Type LOG Severity WARNING Probable Cause Indicates that the received link state record (LSR) contained an invalid domain number. Recommended Action No action is required; the LSR is discarded. FLOD-1006 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 450
of range because it does not exist on the switch. Recommended Action No action is required. This is a temporary kernel error that does not affect your system. If the problem persists, execute the supportSave command and contact your service provider. FSPF-1002 Message Wrong neighbor ID ( - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 451
to identify a set of switches that share an identical topology database. Recommended Action This switch does not support a non-zero section ID. Any connected switch from another manufacturer with a section ID other than 0 is incompatible in a fabric of Brocade switches. Disconnect the incompatible - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 452
and lsdbShow commands to identify the neighbor domains that violate the ICL connectivity requirement. FSPF switch. Recommended Action No action is required. FSPF-1011 Message 16G ICL topology is unbalanced. Message Type LOG Severity WARNING Probable Cause Indicates that the current configuration - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 453
topology imbalances have been corrected. Message Type LOG Severity INFO Probable Cause Indicates that the existing inter-chassis link (ICL) configuration that was resulting in an unbalanced topology has been corrected. Recommended Action No action is required. Fabric OS Message Reference 431 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 454
using the haSyncStart command. For non-bladed systems, restart the switch using the reboot command. If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 432 Fabric - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 455
using the haSyncStart command. For non-bladed systems, restart the switch using the reboot command. If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. FSS-1005 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 456
connection. Message Type LOG Severity CRITICAL Probable Cause Indicates that the Ethernet connection command to validate the network configuration and then execute the haSyncStart command to restore the high availability (HA) synchronization. If the problem persists, contact your switch service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 457
Cause Indicates that a Fabric OS state synchronization (FSS) error may have occurred. Recommended Action Execute the supportSave command and contact your switch service provider. FSS-1011 Message FSS Info: . Message Type LOG Severity INFO Probable Cause Indicates a Fabric - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 458
does not synchronize, execute the haDump command to diagnose the problem. If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. FSSM-1004 Message Incompatible software - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 459
FSSM-1004 5 Recommended Action For a dual CP system, execute the firmwareDownload command to load compatible firmware on the standby CP. Fabric OS Message Reference 437 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 460
Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Typically, low temperatures mean that the fans and airflow of a switch are functioning normally. Verify that the location temperature is within the operational range of the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 461
of the end-user installation. If you receive a temperature-related message, check for an accompanying fan-related message and check fan performance. If has fallen below the low boundary. Fan problems typically contribute to temperature problems. Recommended Action Consistently abnormal fan speeds - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 462
supply is functioning below the acceptable boundary, verify that it is seated correctly in the chassis. Run the psShow command to view the status of the power supply. If the power supply continues to be a problem, replace the faulty power supply. 440 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 463
it is correctly seated in the chassis. If the problem persists, replace the faulty power supply. FW-1011 the power supply is functioning properly. Recommended Action Set the high boundary above the normal operation range end-user installation. Fabric OS Message Reference 441 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 464
below the low boundary. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1035 Message , is above high boundary(High=, Low=). Current value is . Message Type - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 465
Type LOG Severity INFO Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) has changed. The receive performance area measures the amount of incoming laser to help you determine whether the SFP is in good working condition. If the counter often exceeds - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 466
to this message as is appropriate to the particular policy of the end-user installation. FW-1041 Message , value has changed(High= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 467
value outside of the acceptable range to a value within the acceptable range. The transmit performance area measures the amount of outgoing laser to help you determine whether the SFP is to the particular policy of the end-user installation. Fabric OS Message Reference 445 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 468
may indicate a hardware failure. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. If the message persists, replace the SFP. FW-1046 Message , is below low boundary(High=, Low= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 469
to this message as is appropriate to the particular policy of the end-user installation. FW-1049 Message , value has changed(High= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 470
to this message as is appropriate to the particular policy of the end-user installation. FW-1053 Message , is below low boundary(High= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 471
may be caused by transient errors. Recommended Action Check both ends of the physical connection and verify that the SFPs and cables are functioning properly the particular policy of the end-user installation. A low number of E_Port failures means that the switch is functioning normally. Fabric OS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 472
appropriate to the particular policy of the end-user installation. Check both ends of the physical connection and verify that the SFP functions properly. occurrences can cause a fabric reconfiguration: • Two switches with the same domain ID have connected to one another. • Two fabrics have joined. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 473
particular policy of the end-user installation. FW-1119 switch link (ISL) cables are properly connected at both ends. Verify that the small form-factor pluggable (SFP) has not become faulty. An inexplicable fabric reconfiguration might be a transient error and might not require troubleshooting - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 474
switches with the same domain ID have connected to one another. • Two fabrics have joined. • An E_Port has gone offline. • A principal link has segmented from the fabric. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 475
of domain IDs in a single fabric and the principal switch has to assign another domain ID to the switch. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1125 Message , value has changed(High - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 476
switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 477
has changed. Zone changes occur when there is a change to the effective zone configuration. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1130 Message , is below low boundary(High= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 478
boundary. Zone changes occur when there is a change to the effective zone configuration. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1132 Message , is between high and low boundaries(High - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 479
a port or device initializes with the fabric. The event is called fabric login (FLOGI). Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1136 Message , is between high and low boundaries(High - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 480
or removed. A low number of SFP state changes means that the switch is functioning normally. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1139 Message , is above high boundary(High= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 481
loss errors means that the switch is functioning normally. Recommended Action Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. Respond to this message as is appropriate to the particular policy of the end-user installation. Fabric OS Message Reference - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 482
problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Recommended Action Check both ends of your cable connection if applicable, troubleshoot them. Respond to this message as is appropriate to the particular policy of the end-user installation. FW - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 483
FW-1165 5 Recommended Action Check both ends of your cable connection. Verify that the cable and SFPs are not faulty. If you continue to experience synchronization loss errors, troubleshoot your host bus adapter (HBA) and contact your switch service provider. FW-1165 Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 484
physical problem. Recommended Action Check both ends of your cable connection. problem. A low number of signal loss errors means that the switch is functioning normally. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 485
of signal losses that the port experiences has risen above the high boundary. Loss of signal generally indicates a physical problem. Recommended Action Check both ends of your cable connection. Verify that the cable is not faulty. FW-1171 Message , is between high and low - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 486
problems. A low number of protocol errors means that the switch is functioning normally. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user to hardware problems. Recommended Action Check both ends of your connection. Verify - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 487
indicate a hardware problem with a small form-factor pluggable (SFP) or cable. A low number of invalid words means that the switch is functioning normally. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 488
particular policy of the end-user installation. Check your small form-factor pluggables (SFPs), cables, and connections for faulty hardware. switch is functioning normally. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 489
No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Check your small form-factor pluggables (SFPs), cables, and connections for faulty hardware. Verify that all optical hardware is clean. FW-1184 Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 490
risen above the high boundary. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1187 Message , is between high and low boundaries(High=, Low=). Current value is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 491
port experiences has changed. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1189 Message , is below low boundary(High=, Low=). Current value is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 492
or has become a trunk port. A low number of port state changes means that the switch is functioning normally. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. 470 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 493
as is appropriate to the particular policy of the end-user installation. FW-1195 Message , resets that the port experiences has changed. Link resets occur due to link timeout errors that indicate no frame activity. Recommended Action Check both ends of your cable connection - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 494
resets means that the switch is functioning normally. Recommended Action Respond to this message as is appropriate to the particular policy of the end-user physical and hardware problems can cause link resets to increase. Recommended Action Check both ends of your cable connection. Verify if the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 495
below the low threshold. A low number of C3 transmit timeout means that the switch is functioning normally. Recommended Action Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1202 Message , is above high boundary(High= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 496
5 FW-1203 FW-1203 Message , is between high and low boundaries(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the number of C3 transmit timeout frames is between the high and low thresholds. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 497
Indicates that the number of Arbitrated Loop Physical Address (ALPA) cyclic redundancy check (CRC) errors has changed. This indicates that errors have been detected in the FC frame. Invalid CRC messages occur when the number of CRC errors in Fibre Channel frames for specific source ID (S_ID) and - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 498
the number of Arbitrated Loop Physical Address (ALPA) cyclic redundancy check (CRC) errors has fallen below the low boundary. This indicates that errors have been detected in the FC frame. Invalid CRC messages occur when the number of CRC errors in Fibre Channel frames for specific source ID (S_ID - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 499
equipment. You should set your high boundaries to five- or six-digit figures, because only large numbers of messages indicate a problem in this area. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1240 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 500
of CRC errors in Fibre Channel frames for specific source ID (S_ID) and destination ID (D_ID) pairs change. These messages might also be caused by dirty equipment, temperature fluctuations, and aging equipment. Recommended Action The CRC error area of the end-to-end performance monitor class helps - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 501
the switch receives has changed. Receive performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 502
the switch transmits has changed. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 503
Severity INFO Probable Cause Indicates that the number of end-to-end word frames that the switch transmits has risen above the high boundary. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair. Recommended Action No action - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 504
(SCSI) Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP commands in a frame. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1274 Message , is above high boundary(High= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 505
IP address. The TELNET_POLICY contains a list of IP addresses that are authorized to establish Telnet connections to switches in the fabric. Recommended Action Execute the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 506
IP address. The HTTP_POLICY contains a list of IP addresses that are authorized to establish browser connections to the switches in the fabric. Recommended Action Execute the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 507
IP address. The HTTP_POLICY contains a list of IP addresses that are authorized to establish browser connections to the switches in the fabric. Recommended Action Execute the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 508
) contains a list of IP addresses that are authorized to establish API connections to switches in the fabric. Recommended Action Execute the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 509
"get" operation request has been received from an unauthorized IP address. Recommended Action Execute the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 510
indicate that an SNMP "get/set" operation request has been received from an unauthorized IP address. Recommended Action Execute the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 511
indicate that an SNMP "get/set" operation request has been received from an unauthorized IP address. Recommended Action Execute the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 512
the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. LOG Severity INFO Probable Cause Indicates that the number of SCSI Enclosure Services (SES) violations has fallen below the low boundary. SES violations indicate - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 513
Cause Indicates that the number of SCSI Enclosure Services (SES) violations has changed from a value Recommended Action Execute the errShow command to determine the WWN of the device that Responses to security-class messages depend on user policies. Consult your security administrator for response - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 514
sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. a list of switch World Wide Names (WWNs) for which serial port access is enabled. Recommended Action Execute the errShow command to determine the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 515
contains a list of switch World Wide Names (WWNs) for which serial port access is enabled. Recommended Action Run the errShow command to determine the WWN of the device that sent the request. Responses to security-class messages depend on user policies. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 516
a list of switch World Wide Names (WWNs) for which front panel access is enabled. Recommended Action Execute the errShow command to determine the WWN of the device that sent the request. Responses to security-class messages depend on user policies. Consult - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 517
switches by World Wide Name (WWN) that are allowed to be members of a fabric. Recommended Action Execute the errShow command to determine the WWN of the device that sent the request. Responses to security-class messages depend on user the number of Switch Connection Control (SCC) policy violations - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 518
for binding device ports (typically HBA ports) to specific switch ports. DCC policies ensure that whenever a device performs a fabric login (FLOGI) request, the World Wide Name (WWN) specified in the FLOGI is validated to be connected to the authorized port. Enforcement for private loop devices not - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 519
login (FLOGI) request, the World Wide Name (WWN) specified in the FLOGI is validated to be connected to the authorized port. Enforcement for private loop devices not performing FLOGI is done through the name server. Recommended Action Execute the errShow command to determine the device WWN, switch - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 520
for binding device ports (typically HBA ports) to specific switch ports. DCC policies ensure that whenever a device performs a fabric login (FLOGI) request, the World Wide Name (WWN) specified in the FLOGI is validated to be connected to the authorized port. Enforcement for private loop devices not - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 521
has risen above the high boundary. Login violations indicate that a login failure has been detected. Recommended Action Execute the errShow command to determine the IP location of the login attempt. Responses to security-class messages depend on user policies. Consult your security administrator - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 522
an invalid timestamp has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its current time. If the difference - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 523
fabric configuration server (FCS). When the primary FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch must verify this signature with the public key of the primary FCS switch. If verification - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 524
fabric configuration server (FCS). When the primary FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch must verify this signature with the public key of the primary FCS switch. If verification - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 525
fabric configuration server (FCS). When the primary FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch must verify this signature with the public key of the primary FCS switch. If verification - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 526
the sender is the primary FCS switch and its certificate is signed by the Root CA recognized by the receiving switch. This counter keeps track of the number of packets received with invalid certificates. Recommended Action Responses to security-class messages depend on user policies. Consult your - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 527
certificate has been received from the primary fabric configuration server (FCS). Before a new primary FCS switch sends any configuration data to any switch in the fabric, it first sends its certificate to all the switches in the fabric. The receiving switch has to verify that the sender is the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 528
the number of authentication failures has risen above the high boundary. Authentication failures can occur for many reasons. The switch on the other side may not support the protocol, have an invalid certificate, not be signed properly, or send unexpected packets. The port where authentication fails - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 529
Message Type LOG Severity INFO Probable Cause Indicates that the number of switch link authentication protocol (SLAP) faulty packets has fallen below the low Action Responses to security-class messages depend on user policies. Consult your security administrator for response strategies - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 530
>. Message Type LOG Severity INFO Probable Cause Indicates that the number of time service (TS) out-of-sync violations has changed. Recommended Action Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. FW-1365 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 531
Type LOG Severity INFO Probable Cause Indicates that the number of time service (TS) out-of-sync violations has changed from a value FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes. Recommended Action Responses to security-class messages depend on user - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 532
fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes. Recommended Action Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 533
connects only to another switch that is in secure mode and has a compatible security database. A compatible security database means that the version stamp and fabric configuration server (FCS) policy matches exactly. Recommended Action Responses to security-class messages depend on user policies - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 534
that can be executed only on a backup FCS switch. The counter increments every time someone issues one of these commands on a switch where it is not allowed. Recommended Action Responses to security-class messages depend on user policies. Consult your security administrator for response strategies - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 535
that can be executed only on a backup FCS switch. The counter increments every time someone issues one of these commands on a switch where it is not allowed. Recommended Action Responses to security-class messages depend on user policies. Consult your security administrator for response strategies - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 536
. This counter tracks how many times commands allowed only on the primary fabric configuration server (FCS) switch have been executed on a non-primary FCS switch. There are many commands that can be executed only on the primary FCS switch, as well as one security command that can be executed only on - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 537
operation of the switch. Recommended Action Remove some unwanted files to create some flash space. Execute the supportSave command to remove files to this message as is appropriate to the particular policy of the end-user installation. FW-1404 Message ,is above high boundary(High= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 538
5 FW-1405 FW-1405 Message ,is above high boundary(High=, Low=). Current value is . Message Type AUDIT | LOG Class FW Severity INFO Probable Cause Indicates that the memory usage is below the low memory threshold. Recommended Action No action is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 539
command to determine the policy violation. FW-1425 Message Switch switch status has changed to a healthy state. This occurred because a policy is no longer violated. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 540
of faulty or missing power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Action Replace the faulty or missing power supply. FW-1427 Message Switch status change contributing factor Power supply: bad. Message Type LOG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 541
Bad> bad. Message Type LOG Severity WARNING Probable Cause Indicates that the switch is not in a healthy state. This occurred because the number of faulty fans is greater than or equal to the policy set by the switchStatusPolicySet command. A fan is faulty when the value is not in the acceptable - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 542
to verify if both the CPs have compatible firmware levels. Execute the firmwareDownload command to install the same level of firmware to both CPs. Replace any faulty CPs. If you reset the micro-switch (the latch on the CP blade) on the active CP before the heartbeat was up on a power cycle, and - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 543
the flash memory usage is out of range. The policy was set using the switchStatusPolicySet command. Recommended Action Execute the supportSave command to clear out the kernel flash. FW-1436 Message Switch status change contributing factor Marginal ports: marginal - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 544
than or equal to the policy set by the switchStatusPolicySet command. Recommended Action Execute the switchStatusPolicySet command to modify the SFP policy or to add SFPs to the empty ports. FW-1439 Message Switch status change contributing factor Switch offline. Message Type LOG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 545
FW-1441 5 FW-1441 Message state has changed to . Message Type LOG Severity INFO Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to inserted. This means that a FRU is inserted but not powered on. Recommended Action - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 546
full (2X) redundancy, but the user has previously overridden the Switch Status Policy values pertaining to the number of power supplies. So those values will not be automatically changed. With no AP blades, the default value is 3 (out of service), indicating switch status is down or 0 indicating no - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 547
equal to the policy set by the switchStatusPolicySet command. Recommended Action Replace the faulty core blade. FW-1448 Message Switch status change contributing factor Error ports: Error out of ports:config( percent, - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 548
Email address is configured from configuration file has invalid e-mail addresses. Recommended Action Reconfigure a valid e-mail address the port. Both physical and hardware problems can cause link failures. Link errors occur due to hardware problems. Recommended Action Check for - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 549
. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1512 Message , has dropped below - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 550
to this message as is appropriate to the particular policy of the end-user installation. FW-1514 Message , has dropped below a physical problem. Recommended Action Frequent loss of signal generally indicates a physical problem. Check both ends of your cable connection. Verify - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 551
occur due to software glitches. Persistent protocol errors occur due to hardware problems. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1519 Message , has crossed lower threshold - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 552
problem with a small form-factor pluggable (SFP) or cable. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user small form-factor pluggables (SFPs), cables, and connections for faulty hardware. Verify that all optical hardware - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 553
within the acceptable range. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1524 Message , has dropped below upper threshold boundary to in between(High=, Low= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 554
or has become a trunk port. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1528 Message , has dropped below upper threshold boundary to in between(High=, Low= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 555
errors that indicate no frame activity at all. Both physical and hardware problems can cause link resets to increase. Recommended Action Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1530 Message , has dropped below upper - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 556
5 FW-1532 FW-1532 Message , has dropped below upper threshold boundary to in between(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the number of C3 transmit timeout frames has dropped below - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 557
Type LOG Severity INFO Probable Cause Indicates that Port Fencing is configured for link loss and synchronization loss in previous versions, but upgrading to a new version resets the bit because Port Fencing is not supported. Recommended Action No action is required. You are informed that the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 558
Indicates that the circuit utilization has changed. Recommended Action Respond to this message as is appropriate to the particular policy of the end-user installation. FW-3011 Message is below low boundary(High=, Low=). Current value is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 559
packet loss that the circuit experiences has changed. Recommended Action Respond to this message as is appropriate to the particular policy of the end-user installation. FW-3015 Message is below low boundary(High=, Low=). Current value is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 560
circuit has gone offline or the circuit has come online. Recommended Action Respond to this message as is appropriate to the particular policy of the end-user installation. 538 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 561
FW-3019 5 FW-3019 Message is below low boundary(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates the number of state changes that the circuit experiences is below the low boundary level. The - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 562
for is changed to Minute as Seconds is not supported. Message Type LOG Severity INFO Probable Cause Indicates that the timebase for the class is changed implicitly to minutes because a seconds timebase is not supported. Recommended Action No action is required. 540 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 563
Action Restart the standby CP blade by ejecting the card and reseating it. If the problem persists, replace the standby CP switch has been restarted because of a user action or an error. The switch restart can be initiated by the firmwareDownload, fastBoot, haFailover, and reboot commands - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 564
Execute the errShow command on both control processors (CPs) to view the error log for additional messages that may indicate reason for the switch restart. HAM- on EMAC and will wait for the standby CP to reset it if it is down. Recommended Action No action is required. 542 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 565
run by the high availability manager (HAM) module. Recommended Action The standby CP will take over and reset the active CP. The system will be non is enabled, the switch will automatically restart. Otherwise, execute the reboot command to manually restart the switch. HAM-1008 Message Rebooting - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 566
if the event logged in HAM-1007 has occurred and auto-reboot is disabled. Recommended Action Execute the reboot command to restart the switch manually. HAM-1010 Message Maunually trigger haReboot/reboot for recovery from OOM when appropriate. Message Type LOG Severity CRITICAL Probable - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 567
restartable daemon, but could not restart the daemon. Recommended Action Manually initiate a restart or failover, if needed. HAM-1014 Message Recommended Action Execute the reboot command to restart the system or initiate a failover by using the haFailover command. HAM-1015 Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 568
your switch service provider. HAMK-1002 Message Heartbeat down. Message Type LOG Severity INFO Probable Cause Indicates that the active control processor (CP) blade determined that the standby CP blade is down. This can be a result of a user-initiated action such as firmware download, the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 569
INFO Probable Cause Indicates that the standby control processor (CP) is being reset due to a loss of heartbeat. Typically, this message is displayed restarted. Note that in certain circumstances, a CP may experience a double reset and restart twice. A CP can recover automatically even if it has - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 570
blade or switch (for non-bladed switches). HIL-1103 Message Blower faulted, () is above threshold. Message Type LOG Severity ERROR Probable Cause Indicates that the fan voltage is above threshold. Recommended Action Run the psShow command - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 571
command problem persists, replace the fan FRU or the power supply FRU as necessary. HIL-1105 Message Switch switch voltage is above threshold. This message is specific to non-bladed switches. Recommended Action For switches that do not have field-replaceable units (FRUs), replace the entire switch - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 572
area is well-ventilated and that the room temperature is within the operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. If the fan continues to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 573
of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the non-bladed switches. Recommended Action Replace the fan field-replaceable unit (FRU). For switches that do not have FRUs, replace the entire switch. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 574
minimum threshold. This problem can quickly cause the switch to overheat. This message is specific to non-bladed switches. Recommended Action Replace of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Use the fanShow command to monitor - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 575
-replaceable unit (FRU) has failed or has been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Action Replace the affected fan FRU immediately. HIL-1302 Message blowers failed or missing. Replace failed or - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 576
5 HIL-1304 HIL-1304 Message Two fans failed. Replace failed fan FRUs immediately. Message Type LOG Severity ERROR Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often preceded by a low fan speed message. Recommended Action Replace the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 577
HIL-1307 5 HIL-1307 Message Four or five fans failed. Replace failed fan FRUs immediately. Message Type LOG Severity ERROR Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often preceded by a low fan speed message. Recommended Action - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 578
Probable Cause Indicates recovery from an earlier condition of one or more fans having failed. Recommended Action This can only occur on switches with non-removable fans. It follows a previous indication of faultiness. If the fan continues to generate this message, it indicates oscillation between - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 579
this blade has risen above the warning threshold. Recommended Action Run the fanShow command to verify all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 580
this blade has risen above the critical threshold. This usually follows a high-temperature message. Recommended Action Run the fanShow command to your switch. Refer to the hardware reference manual for your switch for the operational temperature range. If the message persists, replace the blade. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 581
Action Run the fanShow command to verify all the fans problems, make sure that all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within the operational range of your switch. Refer to the hardware reference manual for your switch - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 582
. To help prevent future problems, make sure that all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within the operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 583
range of your switch. Refer to the hardware reference manual for your switch for the operational temperature command to verify temperature values. If any sensor is too high, monitor the switch. Try rebooting or power cycling the switch. HIL-1602 Message Multiple temperature sensors failed. Service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 584
is faulty. This message is applicable only to the Brocade 5100. Recommended Action Ensure the power cord is connected to the unit with a valid power source and then switch on the unit. If the problem persists, try reseating the unit. If the problem still persists, replace the FRU. 562 Fabric OS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 585
move in the same direction or the system will shut down in two minutes. This message is applicable only to the Brocade 6510. Recommended Action Use the chassisShow command to check the airflow directions of the power supply and fan assemblies. Ensure that the airflows run in the same direction - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 586
5 HIL-1650 HIL-1650 Message Unable to detect both WWN cards in chassis. Access to WWN halted. Message Type LOG Severity ERROR Probable Cause Indicates that one or both of the World Wide Name (WWN) cards is missing. Both WWN cards must be present for normal operation. Recommended Action Make - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 587
Fabric OS, the HLO dead timeout value is not configurable, so this error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended Action The dead timeout value of the remote switch must be compatible with the value specified in the FSPF protocol. Refer - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 588
can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended Action The HLO message of the remote switch must be compatible with the value specified in the FSPF protocol. Refer to the documentation for the other manufacturer's switch to change this value - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 589
Recommended Action Execute the firmwareDownload command to reinstall the firmware to your switch. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 590
errors. Recommended Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. HSL-1001 Message Failed to acquire system MAC address pool. Message Type LOG Severity CRITICAL Probable - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 591
Recommended Action Disable the interface using the shutdown command and insert an SFP transceiver that is supported on the interface. After the SFP transceiver Synchronization (FSS) service. This error is caused by other system errors. Recommended Action Execute the errShow command to view the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 592
Recommended Action Disable the interface using the shutdown command and re-insert the SFP transceiver. After the SFP transceiver is inserted, re-enable the interface using the no shutdown command. If the problem persists, contact your switch service provider. 570 Fabric OS Message Reference 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 593
refer to the Fabric OS Administrator's Guide. HTTP-1002 Message Zoning transaction initiated by User: , Role: completed successfully. Message Type message log by using the errShow command, and take appropriate corrective actions. Fabric OS Message Reference 571 53- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 594
. Message Type LOG Severity ERROR Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Action Power cycle the blade using the slotPowerOff and slotPowerOn commands. 572 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 595
Severity INFO Probable Cause Indicates that the gateway IP address has been changed manually or it was reconfigured automatically by the Dynamic Host Configuration Protocol (DHCP) server. Recommended Action No action is required. IPAD-1002 Message Switch name has been successfully changed to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 596
5 IPAD-1003 IPAD-1003 Message DNS parameters saved successfully. Message Type LOG Severity INFO Probable Cause Indicates that the Domain Name System (DNS) parameters are saved successfully. Recommended Action No action is required. IPAD-1004 Message DNS parameters removed successfully. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 597
commands to add the license to your switch and activate it. IPS-1002 Message Failed to initialize rc = . Message Type LOG Severity ERROR Probable Cause Indicates that the initialization of a module within the IPS daemon failed. Recommended Action Download a new firmware - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 598
to set up the tunnel. IPS-1006 Message Tunnel Configuration Mismatch for slot () port() tunnel ID() reason (). Message Type LOG Severity WARNING Probable Cause Indicates that tunnel setup failed because of a configuration mismatch between the two ends. The - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 599
Probable Cause Indicates that the tunnel configuration failed because the FX8-24 blade is not at the correct revision to support IPSec enabled tunnels on VEs 22-31. Recommended Action Contact your switch vendor to acquire the correct hardware revision blade. Fabric OS Message Reference 577 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 600
INFO Probable Cause Indicates that the IP address of the Internet Storage Name Service (iSNS) server is zero. Therefore, peering is disabled. Recommended Action If you wish to enable the iSNS server, use the isnscCfg command to show or set the server IP address; otherwise, no action is required - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 601
Service (iSNS) client fails to receive a successful response for a DevAttrQry within the specified registration period. Recommended Action Verify the connection of the iSNS server to the slot and port. ISNS-1005 Message User request re-register with external iSNS server - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 602
IP address> not started because configuration unchanged. Message Type LOG Severity INFO Probable Cause Indicates that peering with the external Internet Storage Name Service to the appropriate hardware reference manual for valid slot and port ranges. 580 Fabric OS Message Reference 53-1002749- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 603
that the Internet Storage Name Service (iSNS) client failed to establish a connection with the iSNS server. Recommended Action Verify the connection of the iSNS server to the slot and port. Use the isnscCfg command to display or correct the server IP address. ISNS-1014 Message Start peering - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 604
configured key vault is operational; if not, change the switch key vault settings or resolve the operational problem switch and the key vault. Recommended Action Establish a trustee link between the switch and the key vault. Refer to the Fabric OS Encryption Administrator's Guide for instructions - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 605
configured key vault is operational; if not, change the switch key vault settings or resolve the operational problem at 1009 Message Primary() and Backup() Key Vaults are not using instructions provided by the key vault provider. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 606
(DEK) to the key vault failed. Recommended Action No action is required. KAC-1011 Message Archival of Dummy DEK to the KV failed. Dummy DEK: , KeyCount: . Error code=, string=. Message Type LOG Severity WARNING Probable - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 607
IP>. Error code=, string=. Message Type LOG Severity ERROR Probable Cause Indicates that the Key Archive Client (KAC) is unable to communicate with the primary or backup key vault. Recommended Action Change the switch key vault settings and make sure the configured - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 608
vault is operational; if not, change the switch key vault settings or resolve the operational problem at the key vault. KAC-1017 Message Error: KV parameter [] configured on BES is not supported by the Key Vault. Please fix the configuration of the parameter to ensure key operations - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 609
ID>. Message Type FFDC | LOG Severity WARNING Probable Cause Indicates that a process on the switch has ended unexpectedly. Recommended Action Copy the warning message along with any core file information and contact your switch service provider. Fabric OS Message Reference 587 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 610
the dump memory size has exceeded the dump file size. Recommended Action Execute the supportSave command and reload the switch. If the problem persists, contact your switch service provider. KTRC-1002 Message Concurrent trace dumping. Message Type LOG Severity INFO Probable Cause Indicates - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 611
advanced technology attachment (ATA) dump device has exceeded. Recommended Action Execute the supportSave command and reload the switch. If the problem persists, contact your switch service provider. KTRC-1005 Message Trace initialization failed. . - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 612
Error: Message queue create failed. Message Type LOG Severity ERROR Probable Cause Indicates that the Layer 2 system (L2SYS) encountered system service manager (SSM) message queue errors. Recommended Action Reboot or power cycle the switch. 590 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 613
AVL tree. Recommended Action Reboot or power cycle the switch. L2SS-1005 Message MAC-address-table hash failed even after two attempts for slot < MAC) address table on the chip is 95 percent full. Recommended Action Clear some of the entries using the no mac-address-table static command or wait - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 614
full. Message Type LOG Severity INFO Probable Cause Indicates that the media access control (MAC) address table on the specified chip is less than 90 percent full. Recommended Action No action using the clear counters access-list mac command. 592 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 615
: HW/Driver Error (possibly the CAM is full): , rc=. Message Type LOG Severity ERROR Probable Cause Indicates an error in the hardware or the driver of the Layer 3 subsystem (L3SS). L3SS may have passed invalid parameters or the hardware Content Addressable - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 616
Severity ERROR Probable Cause Indicates that initialization of the specified module within the Link Aggregation Control Protocol (LACP) daemon has failed. Recommended Action Download a new firmware using the firmwareDownload command. LACP-1002 Message . Message Type LOG Severity ERROR - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 617
. Message Type LOG Severity ERROR Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Action Power cycle the blade using the slotPowerOff and slotPowerOn commands. Fabric OS Message Reference 595 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 618
is enabled. Note that the Logical Fabric Manager service is enabled by the factory setting and it is not user-configurable. Recommended Action No action is required. LFM-1003 Message The Logical Fabric Manager configuration is set to default. Message Type LOG Severity INFO Probable Cause - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 619
the supportsave information using the supportsave command and contact the Brocade technical support. LFM-1005 Message Logical port < be compatible with XISL use. Message Type LOG Severity WARNING Probable Cause Indicates that the firmware version on the specified switch is not compatible with - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 620
Action Execute the reboot command for non-bladed switches or the haFailover command on bladed switches. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 598 Fabric - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 621
flooding and was blocked. Recommended Action Execute the reboot command. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. LOG-1005 Message Log message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 622
Cause Indicates that the specified message has been enabled for logging. Recommended Action No action is required. LOG-1007 Message Log Module has been disabled. Message Type AUDIT | LOG Class RAS Severity INFO Probable Cause Indicates that the specified - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 623
LOG-1009 5 LOG-1009 Message Internal Log message has been enabled for syslog logging. Message Type LOG Severity INFO Probable Cause Indicates that the specified internal message has been enabled for syslog logging. Recommended - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 624
. The valid link state ID is the same as the valid domain ID, with a range from 1 through 239. The switch will discard the record because it is not supported. Recommended Action No action is required. LSDB-1002 Message Local Link State Record reached max incarnation. Message Type LOG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 625
LSDB-1004 5 Recommended Action Run the switchDisable and switchEnable commands. A new local LSR is generated during the switch enable. LSDB-1004 Message No Link State Record for domain . Message Type LOG Severity WARNING Probable Cause Indicates that there is no link - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 626
Action Restart the multicast subsystem (MCAST_SS) daemon. MCAST_SS-1003 Message Learning error: () - VLAN MAC/group . Message Type LOG Severity ERROR Probable Cause Indicates that the multicast subsystem (MCAST_SS) has encountered an error while learning the media - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 627
Message Type LOG Severity ERROR Probable Cause Indicates that the multicast subsystem (MCAST_SS) has encountered an error during a network service module (NSM) event. Recommended Action Restart the MCAST_SS daemon. MCAST_SS-1005 Message Message error: Invalid message type expecting - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 628
(HAL) errors. Recommended Action Restart the MCAST_SS daemon. MCAST_SS-1009 Message L2SS error : () VLAN MAC . Message Type LOG Severity ERROR Probable Cause Indicates that the multicast subsystem (MCAST_SS) has encountered the Layer 2 subsystem (L2SS) related - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 629
daemon. MCAST_SS-1013 Message Snooping DB error: () Group Not found - VLAN group . Message Type LOG Severity ERROR Probable Cause Indicates that the group address lookup for the specified VLAN has failed. Fabric OS Message Reference 607 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 630
Action Restart the MCAST_SS daemon. MCAST_SS-1015 Message HSL error: () failed for message VLAN MAC mgid CPU . Message Type LOG Severity ERROR Probable Cause Indicates that the specified hardware subsystem layer (HSL) related operation - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 631
the memory allocation. Recommended Action Restart the MCAST_SS daemon. MCAST_SS-1019 Message Ptree Error: () VLAN MAC/group . Message Type LOG Severity ERROR Probable Cause Indicates that the multicast subsystem (MCAST_SS) has encountered an error during the Ptree - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 632
5 MCAST_SS-1020 MCAST_SS-1020 Message List Error: () VLAN MAC group . Message Type LOG Severity ERROR Probable Cause Indicates that the multicast subsystem (MCAST_SS) has encountered an error during the List operation. Recommended Action Restart - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 633
If the message persists, run the reboot or the haFailover command (if applicable). If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. MFIC-1002 Message Chassis FRU header not - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 634
information purposes only, and no action is required. IDID mode can be set using the configure command in the CLI or checking the Advanced Web Tools Switch Admin > Configure > Fabric > Insistent Domain ID Mode check box. The switch must be disabled to change the IDID mode. 612 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 635
in the VPD block 0 is bad. This could indicate corruption or tampering. Recommended Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. Fabric OS Message Reference 613 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 636
cost path (MPATH) uses a tree structure in which the parent is used to connect to the root of the tree. Recommended Action No action is required. MPTH-1002 Probable Cause Indicates that the fabric shortest path first (FSPF) module has determined that there is no minimum cost path (MPATH) - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 637
MQ-1004 5 MQ Messages MQ-1004 Message mqRead, queue = , queue ID = , type = . Message Type LOG Severity ERROR Probable Cause Indicates an unexpected message has been received in the specified message queue. The queue name value is always fspf_q. The queue - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 638
5 MQ-1006 MQ-1006 Message queue : msg too long (:). Message Type LOG Severity WARNING Probable Cause Indicates the incoming message size is larger than the message queue size. Recommended Action No action is required. 616 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 639
required. • GCAP sup but not PL by: Set the flag for the MS platform service. • GCAP Rejected (reason =BUSY) by: Execute the firmwareDownload command to upgrade the firmware level on the switch to a level that supports reliable commit service (RCS). RCS is supported in Fabric OS v2.6, v3.1 and later - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 640
matches the Management Server known domains. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. MS-1004 Message MS detected ONLY 1 Domain(d= - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 641
response, which violates the Fibre Channel - Generic Services (FS-GS) specification. Recommended Action Check the integrity of the FC switch at the specified domain. command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 642
RLIR incidents are likely the result of SAN hardware problems such as bad cables or small form-factor pluggable command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. MS-1022 Message Management Server Platform Service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 643
INFO Probable Cause Indicates that the Management Server (MS) topology discovery service is being enabled or disabled. Recommended Action No action is required. MS-1024 Message Management Server Access Control List is Updated. Message Type LOG Severity INFO Probable Cause Indicates that the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 644
that the Management Server (MS) has disabled the specified E_Port connected to the specified domain because an implicit enable operation of the MS platform service has been blocked. Recommended Action Enable MS platform service on the switch and re-enable the port to join the fabric. MS-1027 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 645
for domain . Message Type AUDIT | LOG Class FABRIC Severity ERROR Probable Cause Indicates that fabric name configure or clear operation failed in Fibre Channel Router (FCR). Recommended Action Wait for fabric to stabilize and retry the operation. Fabric OS Message Reference 623 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 646
Cause Indicates a connection, transfer, or receiving error in the socket. Recommended Action If this is a bladed switch, execute the haFailover command. If the problem persists or if this is a non-bladed switch, download a new firmware version using the firmwareDownload command. 624 Fabric OS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 647
MSTP-2001 5 MSTP-2001 Message . Message Type LOG Severity INFO Probable Cause Indicates that the multiple spanning tree protocol (MSTP) bridge mode has changed. Recommended Action No action is required. MSTP-2002 Message . My Bridge ID: Old - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 648
5 MSTP-2004 MSTP-2004 Message MSTP instance is deleted. Message Type LOG Severity INFO Probable Cause Indicates that the specified multiple spanning tree protocol (MSTP) instance has been deleted. Recommended Action No action is required. MSTP-2005 Message VLAN is < - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 649
Database Acknowledge Wait • 4 - Database Wait • 5 - Full If this error occurs repeatedly, then there is a problem in the protocol implementation between two switches. Recommended Action Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it is Full, then - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 650
LOG Severity WARNING Probable Cause Indicates the database transmit set flag was not set for the specified input state on the specified port , then there is a problem in the protocol implementation between two switches. Recommended Action Run the nbrStateShow command to check the neighbor state - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 651
Action Execute the firmwareDownload command to upgrade the remote switch to the latest level of firmware. NS-1003 Message Number of local devices , exceeds the standby can support , can't send update. Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 652
commands will be disruptive. Recommended Action To avoid disruption of traffic in the event of an unplanned failover, schedule a firmware download so zone size to 1024 or smaller, or upgrade the software of the remote switch to support 2048 zones. NS-1006 Message Duplicate WWN was - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 653
Open FR devices to a licensed switch. NS-1009 Message NS has detected a device with Node WWN as zero, pid 0x. Message Type LOG Severity WARNING Probable Cause Indicates that a device has logged in with node World Wide Node Name (WWNN) as zero. Brocade Network Advisor (BNA) will - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 654
service (QoS) zone. Recommended Action Remove the CS_CTL configured devices from the QoS zone. NS-1011 Message NS has detected a failover flag disabled TI zone in a base switch disabled failover flag because the routing may not be set up correctly. NS-1012 Message Detected duplicate WWPN [< - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 655
using the show interface command and resolve the protocol dependencies. The following are the possible reason codes: • Admin down • Link protocol port-channel interfaces) • DOT1x authentication failed • BRCD remote link negotiation failed/LLDP disabled • LAG negotiating/failed • LAG admin state is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 656
Check whether the connectivity between the peer ports is proper, and the remote link is up using the show interface command. NSM-1004 FCoE VLAN. Message Type LOG Severity INFO Probable Cause Indicates that the specified Fibre Channel over Ethernet (FCoE) VLAN is used in the FCoE daemon (fcoed) - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 657
has been enabled or disabled. Recommended Action No action is required. NSM-1008 Message Blade () is . Message Type LOG Severity INFO Probable Cause Indicates that the specified blade has been enabled or disabled. Recommended Action No action is required. NSM-1009 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 658
5 NSM-1010 NSM-1010 Message InterfaceMode changed from to for interface . Message Type LOG Severity INFO Probable Cause Indicates that the interface mode has been changed. Recommended Action No action is required. NSM-1011 Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 659
NSM-1013 5 NSM-1013 Message VLAN classifier group is deleted. Message Type LOG Severity INFO Probable Cause Indicates that the specified VLAN classifier group has been deleted. Recommended Action No action is required. NSM-1014 Message VLAN classifier rule is created. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 660
5 NSM-1017 Recommended Action No action is required. NSM-1017 Message Interface is on interface . Message Type LOG Severity INFO Probable Cause Indicates that the logical interface member list has been changed. Recommended Action No action is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 661
NSM-1020 5 NSM-1020 Message Interface is administratively down. Message Type LOG Severity INFO Probable Cause Indicates that the administrative status of the specified interface has changed to down. Recommended Action No action is required. Fabric OS Message Reference 639 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 662
Cause Indicates that the link layer discovery protocol (LLDP) is disabled globally. Recommended Action No action is required. ONMD-1002 Message LLDP global configuration is changed. Message Type LOG Severity INFO Probable Cause Indicates that the link layer discovery protocol (LLDP) global - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 663
feature is used to detect the Data Center Bridging eXchange (DCBX) version on the specified interface. The DCBX version field will be automatically updated between the Converged Enhanced Ethernet (CEE) version and the pre-CEE version depending on the link neighbor. Recommended Action No action is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 664
configuration file during the installation. Recommended Action Execute the firmwareDownload command to reinstall the firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 665
FSS). Recommended Action Execute the firmwareDownload command to reinstall the firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. PDM-1006 Message Too many - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 666
Execute the firmwareDownload command to reinstall the firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. PDM-1009 Message Can't update Port Config Data - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 667
file. Recommended Action Execute the firmwareDownload command to reinstall the firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. PDM-1011 Message File - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 668
empty. Recommended Action Execute the firmwareDownload command to reinstall the firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. PDM-1014 Message Access - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 669
one line of the pdm.conf file is too long. Recommended Action Execute the firmwareDownload command to reinstall the firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 670
Data Manager (PDM) cannot synchronize with its peer because the firmware does not support IPv6. Recommended Action Configure the local switch with IPv4 addresses. PDM-1023 Message RADIUS is configured with IPv6 addresses. Message Type LOG Severity WARNING Probable Cause Indicates that the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 671
Lightweight Directory Access Protocol (LDAP) server is configured with IPv6 addresses. IPv6 is not supported by older firmware. Recommended Action Configure the LDAP server with IPv4 addresses. PDM-1026 Message User defined roles configured. Message Type LOG Severity WARNING Probable Cause - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 672
. The watchdog register codes are as follows: • 0x10000000 - The watchdog timer (WDT) forced a core reset. • 0x20000000 - The WDT forced a chip reset. • All other code values are reserved. Recommended Action Run the pdShow command to view the panic dump and core dump files. 650 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 673
the system manually using the reboot command. Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. PLAT-1001 Message CP resetting other CP - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 674
. Recommended Action Make sure that all core blade slots have core blades inserted and their ejector switches are closed. Power on core blades that are powered off, and power cycle or replace the core blades that are faulted. Run the chassisenable command to re-enable the ports. Running the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 675
failed. Error message: . Message Type LOG Severity WARNING Probable Cause Indicates that the switch with the specified fabric ID (FID) was not created. Recommended Action Refer to the Error Message string displayed in the message for possible action. PMGR- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 676
. Error message: . Message Type LOG Severity WARNING Probable Cause Indicates an unsuccessful attempt to move the ports to the specified switch. Recommended Action Refer to the Error Message string displayed in the message for possible action. PMGR-1007 Message Attempt to change - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 677
failed. Error message: Message Type LOG Severity WARNING Probable Cause Indicates a failed attempt to change the base switch. Recommended Action Refer to the Error Message string displayed in the message for possible action. Fabric OS Message Reference 655 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 678
5 PMGR-1011 PMGR-1011 Message Attempt to move port(s) to switch succeeded. Message Type LOG Severity INFO Probable Cause Indicates a successful attempt to move the ports to the specified switch. Recommended Action No action is required. 656 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 679
an internally set threshold on the port. This problem is typically related to hardware. Recommended Action Check and replace (if necessary) the hardware attached to both ends of the specified port number, including: • The media (SFPs) • The cable (fiber optic or copper inter-switch link (ISL - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 680
because the port does not support L_Port. If an E_Port or F_Port is connected, then the port will not come up because it is configured to be an L_Port. Recommended Action Execute the portCfgLport command to clear the L_Port configuration. PORT-1006 Message Configuration changed for port (ID - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 681
(ID: ) QoS is disabled. Message Type LOG Severity INFO Probable Cause Indicates that the port quality of service (QoS) is disabled due to the best effort setting on the 4 Gbps or 8 Gbps long distance platform. Recommended Action No action is required. Fabric OS Message Reference - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 682
reboot or power cycle the switch to reinitiate the firmware. PS-1001 Message Advanced Performance Monitoring configuration updated due to change in PID format Guide for more information about the PID format. PS-1002 Message Failed to initialize the tracing system for Advanced Performance - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 683
WARNING Probable Cause Indicates that the restoring configuration has attempted to set the end-to-end monitoring mask on at least one inter-switch link (ISL) port. Recommended Action No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is enabled - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 684
monitors on domain=, because end-to-end monitors are configured on this switch. Message Type LOG Severity WARNING Probable Cause Indicates that end-to-end monitors are configured on the switch. Recommended Action Delete end-to-end monitors on the switch and re-install the fabric mode - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 685
updates in condb database. Message Type LOG Severity WARNING Probable Cause Indicates that the fabric has more than the allowed number of devices. Recommended Action Reduce the number of devices configured port using the perfttmon --add command. Fabric OS Message Reference 663 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 686
wwn>. Message Type LOG Severity INFO Probable Cause Indicates the portSwap command has been issued. Recommended Action No action is required. PSWP-1002 Cause Indicates the port swap feature has been enabled in the switch. Recommended Action No action is required. PSWP-1003 Message Port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 687
result. PSWP-1006 Message Blade Swap failed on configInit with error code in switch number . Message Type LOG Severity WARNING Probable Cause Indicates the bladeSwap command failed on access to configuration data. Recommended Action Retry - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 688
5 PSWP-1007 PSWP-1007 Message Blade Swap failed on fabosInit with error code in switch number . Message Type LOG Severity WARNING Probable Cause Indicates the bladeSwap command failed on access to switch context. Recommended Action Retry the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 689
capture (FFDC) data has reached the maximum. Recommended Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. RAS-1004 Message Software 'verify' error detected. Message Type LOG | FFDC - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 690
(as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. RAS-1006 Message Support data file () automatically transferred to remote address ' '. Message Type LOG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 691
the audit message log has been disabled. Recommended Action No action is required. RAS-2003 Message Audit message class configuration has been changed to . Message Type LOG | AUDIT Class RAS Severity INFO Probable Cause Indicates that the audit event class - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 692
before it was disabled. Recommended Action No action is required. It is recommended to disable the USB storage device using the usbstorage -d command before unplugging it from the system. RAS-3004 Message USB storage device disabled. Message Type LOG Severity INFO Probable Cause Indicates that - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 693
Recommended Action No action is required. RAS-3005 Message CLI: . Message Type AUDIT Class CLI Severity INFO Probable Cause Indicates that the specified command was executed on console. Recommended Action No action is required. RAS-3005 5 Fabric OS Message Reference 671 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 694
later, and v4.1 and later. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. RCS-1002 Message RCS has been enabled. Message Type LOG Severity INFO Probable Cause Indicates that the reliable commit service (RCS) feature has been enabled. RCS must - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 695
in Fabric OS v2.6, v3.1 and later, and v4.1 and later. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. RCS-1005 Message Phase , Application returned , 0x. Message Type LOG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 696
license exists for the remote domain and if the application data is compatible. RCS-1007 Message Zone DB size and propagation overhead exceeds domain 's maximum supported does not support reliable commit service (RCS). Recommended Action Run the fabricShow command to verify that - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 697
> E_Port(s) connected to this switch. Investigate for routing issue or check the cabling, and re-enable the disabled E_Ports to attempt another exchange of RCS-capable information. RCS-1011 Message Remote domain is RCS-incapable. Configure command and contact your switch service provider - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 698
> is RCS incapable. Message Type LOG | FFDC Severity WARNING Probable Cause Indicates that the specified remote domain is RCS-incapable. Recommended Action Execute the supportSave command and contact your switch service provider. 676 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 699
again. RKD-1003 Message encountered a FATAL SCSI error and will be suspended. . Command: ; LBA: ; Num Blocks: 0x; Error: ; SK/ASC: /. Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 700
5 RKD-1004 RKD-1004 Message Message: . Message Type LOG Severity INFO Probable Cause Indicates the generic re-key message. Recommended Action No action is required. RKD-1005 Message LUN with LSN: does no have metadata. Make note of key ID - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 701
type of the remote monitoring (RMON) alarm. Recommended Action Check the traffic on the interface using the show interface command. Note that you can use the show interface command to check the traffic on the interface, provided the statistics on the interface are not cleared using the clear - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 702
. The specified client IP address has faulty credentials. Recommended Action Enter the correct user name and password from the Fabric Access Probable Cause Indicates the Secure Sockets Layer (SSL) certificate file configured on the switch could not be accessed because root did not have read-level - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 703
the private key file is missing. Recommended Action Run the secCertUtil command to install a valid private key file. RPCD-1006 Message Permission LOG Severity WARNING Probable Cause Indicates the private key file configured on the switch could not be accessed because the root did not have - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 704
5 RPCD-1007 Recommended Action Run the secCertUtil command to install a valid private key file. 682 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 705
RTE-1001 Message Detected route inconsistency. It may cause connectivity issues. If such issues arise, bounce all ISLs and event causes route inconsistencies. Recommended Action Reset all E_ports on the chassis using the portDisable and portEnable commands. Fabric OS Message Reference 683 53- - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 706
specified domain ID is offline, enable the switch using the switchEnable command. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 684 Fabric OS Message Reference - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 707
-1003 5 RTWR-1003 Message : RTWR retry - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 708
case, execute the supportSave command to send the core files using FTP to a secure server location. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 686 Fabric OS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 709
case, execute the supportSave command to send the core files using FTP to a secure server location. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 710
command and contact your switch service provider. SEC-1002 Message Security data fails: . Message Type LOG Severity ERROR Probable Cause Indicates that the receiving switch fails to validate the security database sent from the primary fabric configuration server (FCS) switch - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 711
if the updating counter fails. Recommended Action If the message is the result of a user command, retry the statistic command. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 712
. Recommended Action Check for unauthorized access to the switch through the API connection. SEC-1008 Message Security violation: Unauthorized host with IP address tries to establish HTTP connection. Message Type LOG Severity INFO Probable Cause Indicates - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 713
from a non-primary switch. Recommended Action Resolve the specified error by executing the command only from the primary FCS. SEC-1016 Message Security violation: Unauthorized host with IP address tries to establish SSH connection. Message Type LOG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 714
IP address () detected. Message Type LOG Severity ERROR Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only when the primary fabric configuration server (FCS) distributes the security database to the other switches - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 715
fabric configuration server (FCS) distributes the security database to the other switches in the command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that specific switch - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 716
Message Empty FCS list is not command. Only the secPolicyCreate command supports use of the asterisk for adding switches to policies. Recommended Action Run the secPolicyAdd command using a valid switch identifier (WWN, domain ID, or switch name) to add specific switches to the Switch Connection - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 717
does not have the colon character (:) as required. Recommended Action Run the secPolicyCreate or secPolicyAdd command with a properly formatted device name parameter. SEC-1037 Message Invalid WWN format . Message Type LOG Severity ERROR Probable Cause Indicates the WWN entered - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 718
Indicates the domain ID entered is out of range. Recommended Action Verify that the domain ID is correct. If it is not, re-run the command using the correct domain ID. SEC-1040 Message Invalid portlist (). Cannot combine * with port member in the same portlist. Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 719
SEC-1041 5 SEC-1041 Message Invalid port member in portlist (). . Message Type LOG Severity ERROR Probable Cause Indicates the port member is invalid for one of the following reasons: • The value is not a number. • The value is too long. Valid numbers must be - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 720
fabric configuration server (FCS) distributes the security database to the other switches in the command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that specific switch - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 721
fabric configuration server (FCS) distributes the security database to the other switches in the command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that specific switch - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 722
Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that specific switch. SEC-1054 Message Invalid FCS list length - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 723
fabric configuration server (FCS) distributes the security database to the other switches in the command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that specific switch - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 724
flash memory. Recommended Action Run the supportFtp - e command to FTP files from the switch and remove them from the flash memory. SEC-1062 maximum number supported are specified. Recommended Action Enter the correct number of domains. SEC-1063 Message Failed to reset statistics. Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 725
command to verify that all PKI objects are valid. If PKI objects are not valid, generate the PKI objects and install the certificate by following the field upgrade command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 726
is corrupted for unknown reasons. Recommended Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. SEC-1073 Message No FCS policy in list. Message Type LOG Severity ERROR Probable - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 727
. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that specific switch. SEC-1076 Message NoNodeWWNZoning option - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 728
rare occurrence. Recommended Action Run the fabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that specific switch. 706 Fabric OS Message Reference 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 729
the Device Connection Control (DCC) policy name given in the secPolicyCreate command was the command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that specific switch - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 730
name>. Message Type LOG Severity ERROR Probable Cause Indicates the security policy was not created. Recommended Action Check that the current policy configuration is valid. For example, the RSNMP policy cannot exist without the WSNMP policy. SEC-1086 Message The security database is too - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 731
fabric configuration server (FCS) distributes the security database to the other switches in the command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that specific switch - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 732
fabric configuration server (FCS) distributes the security database to the other switches in the command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that specific switch - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 733
. Recommended Action Run the fabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that specific switch. SEC-1095 Message Deleting FCS policy is not allowed - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 734
Action If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. SEC-1098 Message No FCS list. Message Type LOG Severity ERROR Probable Cause Indicates the specified - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 735
that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that specific switch. SEC-1100 Message FCS switch present. Command terminated. Message Type LOG Severity ERROR Probable Cause - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 736
OS Administrator's Guide. SEC-1105 Message Fail to disable secure mode on all switches. Message Type LOG Severity ERROR Probable Cause Indicates the switch failed to disable security in the fabric. This could happen if the switch cannot get the required resources to complete the command, and - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 737
not be correctly updated for that specific switch. SEC-1108 Message Fail to reset stamp on all switches. Message Type LOG Severity ERROR Probable Cause Indicates that a version reset operation failed either because the switch could not get all the required resources to perform the operation or - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 738
Probable Cause Indicates either a security policy download was attempted with an active policy that does not have the fabric configuration server (FCS) policy as the first policy, or the FCS policy is not the same as the current FCS policy on the switch. Recommended Action Make sure that the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 739
new license for this feature. SEC-1115 Message No primary FCS to failover. Message Type LOG Severity ERROR Probable Cause Indicates that during an attempted secFcsFailover, no primary FCS is present in the fabric. Recommended Action Run the secFabricShow command to verify that all switches in - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 740
an FCS password, a non-FCS password, SNMP data, or multiple user authentication data. Recommended Action Run the fabricShow command to verify that all switches in the fabric are in the ready state. When all switches are in the ready state, retry the operation. SEC-1118 Message Fail to set SNMP - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 741
>. Message Type LOG Severity INFO Probable Cause Indicates that one of the switches in the fabric could not communicate with the primary fabric configuration server (FCS). Recommended Action Run the fabricShow command to verify that all switches in the fabric are in the ready state. When all - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 742
Indicates the security database was successfully downloaded from the primary fabric configuration server (FCS). Recommended Action No action is The Primary FCS has failed over to a new switch. Message Type LOG Severity INFO Probable Cause Indicates a fabric configuration server (FCS) failover - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 743
database sent from the primary fabric configuration server (FCS) switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service, or the signature verification failed. Signature - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 744
primary fabric configuration server (FCS) switch received a security database download. Recommended command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that switch - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 745
version from your switch supplier, and run the firmwareDownload command to upgrade the firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 746
not be updated. If the switch is short of memory. The status values can be either defined, active, or both. A negative value means that a policy set commands may take a few minutes to propagate throughout the fabric. Make sure to wait a few minutes between executing commands so that your commands - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 747
command. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service the primary fabric configuration server (FCS) distributes the security database to the other switches in the fabric, - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 748
mode. Recommended Action Do not use the lockdown option with the secModeEnable command when a switch is already in secure mode. SEC-1164 Message Lockdown option cannot be applied on a non-FCS switch. Message Type LOG Severity ERROR Probable Cause Indicates the attempt to enable security - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 749
the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that specific switch. SEC-1167 Message Another FCS failover is in process. Command terminated. Message Type LOG Severity ERROR Probable - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 750
command to install the required license key. Contact your switch supplier to obtain a license if you do not have one. SEC-1172 Message Failed to identify role. Message Type LOG Severity ERROR Probable Cause Indicates the switch is unable to determine its role (primary FCS or backup FCS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 751
fabric configuration server (FCS) switch in the secure fabric. This could result from the primary FCS being disabled. Recommended Action If the primary FCS was disabled intentionally, no action is required; if not, check the primary FCS. SEC-1174 Message Failed to set password - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 752
fabric was not stable. Recommended Action Verify all switches in the fabric are in time synchronization with the primary FCS and that no external entity is trying to No action is required. SEC-1181 Message Deleted account . Message Type LOG Severity INFO Probable Cause Indicates the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 753
command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. SEC-1184 Message configuration authentication dial-in user service (RADIUS/LDAP/TACACS+) server configuration. The possible - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 754
to FLOGI to index/area of switch . Message Type LOG Severity INFO Probable Cause Indicates a Device Connection Control (DCC) security violation was reported. The specified device attempted to log in using fabric login (FLOGI) to an unauthorized port. The DCC policy - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 755
IP address tries to do SNMP write operation. Message Type LOG Severity INFO Probable Cause Indicates an SNMP security violation was reported. The specified unauthorized host attempted to perform host with IP address tries to establish HTTP connection. Message Type - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 756
to log in through the specified connection method; the login failed. Recommended Action The error message lists the violating IP address. Verify that this IP address is being used by a valid switch admin. Use the correct password. SEC-1194 Message This switch does not have all the required - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 757
updated for that specific switch. SEC-1196 Message Switch does not have all default account names. Message Type LOG Severity WARNING Probable Cause Indicates the default switch accounts admin and user do not exist on the switch when enabling security. Recommended Action Reset the default - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 758
server (MS) forward security violation was reported. A management server command was forwarded from a non-primary fabric configuration server (FCS) switch. Recommended Action Check the MS policy and verify that the connection is allowed. If the connection is allowed but not specified, enable the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 759
. An MS device operation occurred on a non-primary fabric configuration server (FCS) switch. Recommended Action Check the management server policy and verify the connection is allowed. If the connection is allowed but not specified, enable the connection in the MS policy. If the MS policy does not - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 760
Connection Control (DCC) policy update to fail in the provision, commit, or cancel phases. Recommended Action Retry the failed security command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 761
occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database may not be correctly updated for that specific switch. Fabric OS Message Reference 739 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 762
Recommended Action Run the firmwareDownload command to update the firmware to the latest version for your specific switch. Verify the firmware you are installing supports the Brocade Secure Fabric OS feature. SEC-1304 Message This switch has no security license. Message Type LOG Severity INFO - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 763
command. SEC-1308 Message All servers failed to authenticate user account ''. Message Type LOG Severity INFO Probable Cause Indicates that all servers in the RADIUS, LDAP, or TACACS+ configuration have failed to respond to a switch request - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 764
, run the passwdCfg --setdefault command on each switch in the fabric to set the password policies to the default values. Then verify with the passwdCfg --show command that password policies are set to the default values on all switches and retry the secModeEnable command. 742 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 765
set to default values. Message Type LOG Severity INFO Probable Cause Indicates the password configuration parameters were set to default values module to retrieve the IP address failed. Recommended Action Reboot the system to fix this error. If the problem persists, contact your switch service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 766
Message command failed - db(s) configured for rejection on this switch. Message Type LOG Severity ERROR Probable Cause Indicates there was an attempt to distribute databases to a switch that was configured not to accept distributions - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 767
Retry the distribution. SEC-1319 Message updated dbs(s). Message Type LOG Severity INFO Probable Cause Indicates Message Type LOG Severity WARNING Probable Cause Indicates that a domain not supporting an access control list (ACL) policy tried to join a fabric - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 768
configuration or AD configuration and retry the secModeEnable command. SEC-1322 Message Some DCC policy is too large, distribution cancelled. Message Type LOG Severity WARNING Probable Cause Indicates this fabric is not able to support a Device Connection during configuration download. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 769
Indicates the reliable commit service (RCS) transaction failed with Security enforcement: Switch connecting to port < switch with the fabric. SEC-1326 Message Event: fddcfg --fabwideset, Status: success, Info: Fabric wide configuration set to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 770
by disallowing all its E_Ports connected to the fabric. If IP filter policy enforcement failed because of an internal system failure. Recommended Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 771
FCS switch. Use the secPolicyShow command to verify and correct the configuration if necessary. SEC-1331 Message Attempt to enable secure mode failed. Reason: . Message Type LOG Severity ERROR Probable Cause Indicates the secModeEnable command failed on the fabric because default IP - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 772
SEC-1333 SEC-1333 Message command failed. There are VF enabled switch(s) in fabric. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 773
switch. Recommended Action Check the conflicting policy and make the new switches and the local switch policies the same. SEC-1337 Message Plain-text password is sent during console login INFO Probable Cause Indicates the password configuration parameters changed. Recommended Action Verify - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 774
. The event can be one of the following: • There has been a fabric configuration server (FCS) failover. • A security policy has been activated. • A security policy has been saved. • A security policy has been aborted. • A non-FCS password has changed. 752 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 775
SEC-3003 5 Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. SEC-3003 Message Event: , Status: success, - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 776
Class SECURITY Severity INFO Probable Cause Indicates a user has removed the specific members from the FCS member moved from position to . Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates the fabric configuration server (FCS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 777
Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates a user has reset all the security statistics. Recommended Action Verify the security statistics were intentionally reset. If the security statistics were intentionally reset, no action is required. If the security statistics were - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 778
Set or Reset> on domain [] for account []. Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates a user has reset the password for the specified user accounts. Recommended Action Verify the password was intentionally reset. If the password was - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 779
enterprise security policy. SEC-3017 Message Event: , Status: success, Info: . Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates a user has changed the RADIUS, LDAP, and TACACS+ configuration. Fabric OS Message Reference 757 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 780
INFO Probable Cause Indicates the password configuration parameters are set to default values. Recommended Action Verify the password configuration parameter was intentionally set to default values. If the password configuration parameter was intentionally set to default values, no action is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 781
: success, Info: Successful login attempt via . Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates a successful login occurred. An IP address is displayed when the login occurs over a remote connection. Recommended Action Verify the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 782
automatically unlock after the lockout duration has expired or an administrator may manually unlock the account. SEC-3024 Message Event: , Status: success, Info: User account [], password changed. Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 783
Name>], role changed from [] to []. Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates a user account role was changed. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 784
user account \"\" recovered. Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates that backup user Severity INFO Probable Cause Indicates the specified secCertUtil operation was performed. Recommended Action Verify the security event was planned. If - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 785
3032 Message Event: , Status: success, Info: Switch is configured to database. Message fabwideset, Status: success, Info: Fabric wide configuration set to . Message Type AUDIT Class SECURITY Severity INFO - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 786
Filter Policy> ipfilter policy(ies) saved. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates the specified IP filter policies has been saved. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 787
INFO Probable Cause Indicates a security violation was reported. The IP address of the unauthorized host is displayed in the message. Recommended Action Check for unauthorized access to the switch through the specified protocol connection. SEC-3044 Message The FIPS mode has been changed to - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 788
security policy. SEC-3046 Message The FIPS Self Tests mode has been set to . Message Type AUDIT Class SECURITY Severity INFO the user does not have permission to execute this command. Recommended Action Verify the user has the required permission to execute this command. 766 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 789
Indicates the status of boot PROM access has changed using the fipsCfg command. Recommended Action No action is required. SEC-3050 Message Event: Cause Indicates the specified Secure Shell (SSH) utility operation was performed. Recommended Action Verify the security event was planned. If the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 790
key is . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that a license key is added or removed. Recommended Action No action is required. SEC-3061 Message Role '' is created. Message Type AUDIT | LOG Class SECURITY - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 791
permission to the Role-Based Access Control (RBAC) class is changed for the specified role name. Recommended Action No action is required. SEC-3065 Message Configuration of user-defined roles is uploaded. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 792
SECURITY Severity INFO Probable Cause Indicates the configuration of user-defined roles has been downloaded. Recommended Action No action is required. SEC cipher list. SEC-4001 Message Client logged in. , , . Message Type AUDIT | LOG Class SECURITY - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 793
SFLO-1001 5 SFLO Messages SFLO-1001 Message sFlow is globally. Message Type LOG Severity INFO Probable Cause Indicates that sFlow is globally enabled or disabled. Recommended Action No action is required. SFLO-1002 Message sFlow is for port . Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 794
action is required. SFLO-1007 Message is as sFlow collector. Message Type LOG Severity INFO Probable Cause Indicates that the sFlow collector is configured or not configured. 772 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 795
required. SFLO-1008 Message All the sFlow collectors are unconfigured. Message Type LOG Severity INFO Probable Cause Indicates that none of the sFlow collectors are configured. Recommended Action No action is required. SFLO-1008 5 Fabric OS Message Reference 773 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 796
will not be able to query the switch through SNMP. Recommended Action Verify that the IP address for the Ethernet and Fibre Channel interface is set correctly. If the specified reason is an initialization failure, restart the switch using the reboot command. SNMP-1002 Message SNMP - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 797
view the new SNMP configuration. SNMP-1006 Message configuration was reset to default. Message Type AUDIT | LOG Class CFG Severity INFO Probable Cause Indicates that the specified SNMP configuration group was reset to the factory default. Recommended Action Execute - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 798
CFG Severity INFO Probable Cause Indicates the blocked or unblocked status of the port traps on the specified port. Recommended Action Execute the snmpTraps --show command to view the current status of the port. 776 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 799
of an internal error. Cryptographic operations are affected. Recommended Action To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To recover a non-bladed system, execute the fastboot command on the switch. Fabric OS Message Reference 777 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 800
. The encryption engine is zeroized. Recommended Action Execute the cryptocfg --initEE and cryptocfg --regEE commands. SPC-2003 Message S, : Data Disable status: 0x. Message Type LOG Severity INFO Probable Cause Indicates - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 801
No action is required. SPC-2005 Message S, : FPGA firmware download success. Message Type LOG Severity INFO Probable Cause Indicates that FPGA download was successful. Recommended Action No action is required. SPC-2006 Message S - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 802
2009 Message S, : Tamper event: User zeroization. Message Type LOG Severity CRITICAL Probable a user zeroize request. The encryption engine is zeroized. Recommended Action Execute the cryptocfg --initEE and cryptocfg --regEE commands. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 803
-test (BIST) was successful. Recommended Action No action is required. SPC-2012 Message S, : User zeroization command completed successfully. Tamper INT status . Message Type LOG Severity INFO Probable Cause Indicates that the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 804
WARNING Probable Cause Indicates hardware failure. Recommended Action The shelf life of the system may be reduced. Contact the vendor for further instructions. SPC-2014 Message S, : Low Battery Level Detected. Message Type LOG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 805
allocation failure for the pool of SB message. Recommended Action No action is required. SPC-2042 Message S, : Alloc msg - no free sbmsgs. Message Type LOG Severity WARNING Probable Cause Indicates no free message buffer in the free pool - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 806
Indicates that the SPD device is not opened. Recommended Action No action is required. SPC-3001 Message S, : No input KEK for DEK inject, DEK: , KEK: - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 807
current or alternate position. SPC-3005 Message S, : DEK inject error: , DEK: - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 808
KEK format Recommended Action For status code 14, complete primary KEK generation; otherwise, contact your switch service provider. SPC-3007 Message S, : DEK create error: , info: . Message Type LOG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 809
containing Encryption Engine>, : FIPS certificate mismatch, certificate: . Message Type LOG --initEE and cryptocfg --regEE commands. SPC-3010 Message S, : SEK integrity failure during - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 810
initEE and cryptocfg --regEE commands, and then recover or module name>: SEK generation failure: . Message Type LOG Severity ERROR Probable Cause Indicates that the CryptoModule internal Secret Encryption Key could not be generated. Recommended Action Contact your switch service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 811
that the CryptoModule internal random number generator has failed. Recommended Action Contact your switch service provider for assistance. SPC-3015 Message S, : RSA pairwise key generation test failure. Message Type LOG Severity ERROR - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 812
FTP transfers; then execute the supportSave command and contact your switch service provider. SPM-1003 Message Set New Group Cfg SC Enable KV Type . Message Type LOG Severity INFO Probable Cause Indicates a new group has been configured. Recommended Action No action is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 813
Node. Message Type LOG Severity INFO Probable Cause Indicates a node initialization. Recommended Action No action is required. SPM-1005 Message Set EE Control slot action . Message Type LOG Severity INFO Probable Cause Indicates specified control action is taken on - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 814
. Message Type LOG Severity ERROR Probable Cause Indicates that the specified certificate is missing. Recommended Action Execute the cryptocfg --initnode command. SPM-1010 Message Key Vault Certificate is missing. Message Type LOG Severity ERROR Probable Cause Indicates that the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 815
Message Type LOG Severity INFO Probable Cause Indicates that a group configuration has changed the quorum size. Recommended Action No action is required Recommended Action Execute the cryptocfg --sync -securitydb command to manually sync the security database. Fabric OS Message Reference 793 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 816
nodes in the EG are running different versions of FOS. Message Type LOG Severity WARNING Probable Cause Indicates a failure to distribute the security database. Recommended Action Use the cryptocfg --sync -securitydb command to manually sync security database. 794 Fabric OS Message Reference - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 817
SPM-3001 5 SPM-3001 Message Event: cryptocfg Status: success, Info: Node [] initialized. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates a node was initialized. Recommended Action No action is required. SPM-3002 Message Event: cryptocfg Status: - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 818
5 SPM-3004 SPM-3004 Message Event: cryptocfg Status: success, Info: EE in slot enabled. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates an encryption engine was enabled. Recommended Action No action is required. SPM-3005 Message Event: cryptocfg Status - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 819
through SCP protocol Recommended Action No action is required. SPM-3008 Message Event: cryptocfg Status: success, Info: DH challenge generated for vault IP . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates a DH challenge was generated for a key vault - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 820
Message Event: cryptocfg Status: success, Info: key vault registered. Certificate label: \"\" Certificate file: \"\" IP address: . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates a key vault was registered - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 821
key archive client (KAC) certificate was registered. Recommended Action No action is required. SPM-3015 Message Event: cryptocfg Status: success, Info: Key vault type set to . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates the key vault type was - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 822
5 SPM-3016 SPM-3016 Message Event: cryptocfg Status: success, Info: Master key generated. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates a master key was generated Recommended Action No action is required. SPM-3017 Message Event: cryptocfg Status: success, - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 823
SPM-3019 5 SPM-3019 Message Event: cryptocfg Status: success, Info: System card registered. Certificate label: \"\" Certificate file: \"\". Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates a system card was registered. Recommended - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 824
use of the system card was enabled or disabled. Recommended Action No action is required. SPM-3024 Message Event: cryptocfg Status: success, Info: Quorum size set to . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates the quorum size was - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 825
SPM-3025 5 SPM-3025 Message Event: cryptocfg Status: success, Info: File imported via USB: Source: Destination: . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates a file was imported through a USB device. Recommended Action No - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 826
Probable Cause Indicates an encryption engine state has changed. Recommended Action No action is required. SPM-3029 Message Event: KeyVault Connection Status: , Info: KAC_Connect: . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates the status - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 827
Check and correct the remote server settings and configuration. Execute the supportFtp command (as needed) to set the FTP or SCP parameters. After the problem is corrected, execute the supportSave command again. SS-1002 Message supportSave has stored support information to the USB storage device - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 828
the active control processor (CP) and the blade in the specified slot. Recommended Action Check for the IP connection between the active CP and the blade in the specified slot. After the IP connection is established, execute the supportSave command again. 806 Fabric OS Message Reference 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 829
WARNING Probable Cause Indicates that the supportsave request was not sent to the blade in the specified slot. Recommended Action Restart the switch using the reboot command and then execute the supportSave command. SS-1007 Message supportsave failed for the slot . Reason: No - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 830
-Subsystem Communication (ISC) connection for the specified node slot. Recommended Action Restart the switch using the reboot command and then execute the supportSave command. SS-1010 Message CORE/FFDC files have been uploaded to the host with IP address . Message Type LOG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 831
Message Type LOG Severity INFO Probable Cause Indicates that a chassis with the blade processor (BP) does not have enough disk space in the secondary files, before uploading them to the remote host. Recommended Action Manually clean up the secondary partition of the active CP to collect the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 832
the switch. SSMD-1002 Message Failed to initialize rc = . Message Type LOG Severity ERROR Probable Cause Indicates that the initialization of a module within System Services Manager (SSM) has failed. Recommended Action Download a new firmware using the firmwareDownload command - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 833
during basic startup and initialization. Recommended Action Restart or power cycle the switch. If the problem persists, download a new firmware using the firmwareDownload command. SSMD-1006 Message Error while configuring ACL on interface . Message Type LOG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 834
the Multicast Rate Limit feature. Recommended Action Delete and reapply the Quality of Service (QoS) Multicast Rate Limit policy using the qos rcv-queue multicast rate-limit command. If the problem persists, restart or power cycle the switch. 812 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 835
. Recommended Action Delete and reapply the QoS Multicast Tail Drop policy using the qos rcv-queue multicast threshold command. If the problem persists, restart or power cycle the switch. SSMD-1202 Message QoS failed programming interface 0x 802.3x Pause flow control. Message Type - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 836
for enforcing the CEE Map Class of Service (CoS) to Priority Group ID (PGID) mapping feature. Recommended Action Delete and reapply the CEE Map CoS to PGID policy using the cee-map default command. If the problem persists, restart or power cycle the switch. 814 Fabric OS Message Reference 53 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 837
Trust feature. Recommended Action Delete and reapply the QoS interface Trust policy using the qos trust cos command. If the problem persists, restart or power cycle the switch. SSMD-1209 Message QoS failed programming interface 0x CoS Mutation map. Message Type LOG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 838
Action Delete and reapply the QoS interface CoS to Traffic Class policy using the qos cos-traffic-class command. If the problem persists, restart or power cycle the switch. SSMD-1211 Message QoS failed programming ASIC / Scheduler Control. Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 839
feature. Recommended Action Delete and reapply the QoS CoS Tail Drop Threshold policy using the qos rcv-queue command. If the problem persists, restart or power cycle the switch. SSMD-1214 Message QoS failed programming interface 0x CoS Tail Drop Threshold. Message Type LOG - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 840
power cycle the switch. SSMD-1217 Message QoS CEE could not comply with FCoE scheduler policy for CEE Map . Message Type LOG Severity WARNING Probable Cause Indicates that DCE SSM was unable to translate the CEE Map and Fibre Channel over Ethernet (FCoE) configuration into an ETS - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 841
SSMD-1301 5 SSMD-1301 Message CEE Map is deleted. Message Type LOG Severity INFO Probable Cause Indicates that the specified CEE Map has been deleted. Recommended Action No action is required. SSMD-1302 Message CEE Map priority table are . Message Type - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 842
5 SSMD-1305 Recommended Action No action is required. SSMD-1305 Message CEE Map priority group weight is changed from to . Message Type LOG Severity INFO Probable Cause Indicates that the specified priority group weight has been changed. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 843
the specified access list rules were added to or removed from an existing policy. Recommended Action No action is required. SSMD-1310 Message ACL configured on interface . Message Type LOG Severity INFO Probable Cause Indicates that the specified access list has been - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 844
Message Type LOG Severity INFO Probable Cause Indicates that the specified user profile map has been assigned to the interface. Recommended Action Message Type LOG Severity INFO Probable Cause Indicates that the specified user profile map has been removed from the interface. Recommended Action - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 845
that the specified CEE Map is incompatible with the current firmware and therefore it is reset to the default. Recommended Action No action is required. SSMD-1316 Message CEE Map is reset to default configuration. Message Type LOG Severity INFO Probable Cause Indicates that the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 846
5 SSMD-1318 SSMD-1318 Message ACL is being removed from interface . This operation could take a long time. Message Type LOG Severity INFO Probable Cause Indicates that the specified access list is being removed from the interface. Recommended Action No action is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 847
INFO Probable Cause Indicates that the firmwareDownload command has completed successfully and switch firmware has been updated. Recommended Action No action is required. The firmwareDownload command has completed as expected. Run the firmwareDownloadStatus command for more information. Run the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 848
processor (CP) has now become the active CP and is running the new firmware version. Recommended Action No action is required. The firmwareDownload command is progressing as expected. Run the firmwareDownloadStatus command for more information. 826 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 849
firmware. Recommended Action No action is required. The firmwareDownload command is progressing as expected. Run the firmwareDownloadStatus command code "Firmware download sanity check failed." "Sanity check failed because system is non-redundant." "Sanity check failed because firmware download is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 850
Unable to restore the secondary partition. Run the firmwareDownloadStatus and firmwareShow commands to see firmware status." "Firmware download has started on standby CP. It might take up to 10 minutes." "Firmware download has completed successfully on standby CP." "Standby CP reboots." Status code - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 851
." 0x82 "Standby CP failed to boot up with new firmware." 0x83 "There was an unexpected reboot during the firmware download operation. The command is aborted." 0x84 "Standby CP was not responding. The command is aborted." 0x85 "Firmware commit has started on both active and standby CPs. Run - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 852
the blade." "Blade rebooted during firmware commit. The operation will be restarted." "Firmware has been downloaded successfully. Blade is rebooting with the new firmware." "Blade has rebooted successfully." "New firmware failed to boot up. Run the firmwareDownload command again." "Firmware commit - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 853
download is already in progress." 0x22 "Firmware download timed out." 0x23 "Out of disk space." 0x24 "Primary filesystem is inconsistent. Run the firmwareRestore command to restore 0x25 the original firmware, or contact your switch service provider for recovery." "The post-install script - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 854
upgrade to an intermediate version before downloading the desired version. If this error occurs in the middle of a firmware download, the firmware in the file server may be corrupted or there may be a temporary network issue. In this case, retry the firmwareDownload command. If the problem persists - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 855
attempting another firmware download. In a modular switch, when the firmwareDownload command fails, the two CPs may end up with different versions of firmware and they may not gain high availability (HA) sync. In this case, run the firmwareDownload -s command to upgrade the firmware on the standby - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 856
, run the slotPowerOff and slotPowerOn commands to trigger another firmware download to the blade. If the blade is stuck in the LOADING state, remove and re-insert the blade to trigger another firmware download. If the problem persists, contact your switch service provider. 834 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 857
commands to trigger another firmware download to the blade. If the blade is stuck in LOADING state, remove and re-insert the blade to trigger another firmware download. If the problem persists, contact your switch service provider. SULB-1021 Message Firmware is being downloaded to the blade - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 858
the end of the firmware commit, the blade firmware version is still inconsistent with the active CP firmware, firmware download will be restarted automatically on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 859
of a firmware download. The error may also be caused by persistent storage hardware failure or by a software error. Recommended Action The firmwareDownload command will continue after the switch has rebooted. Run the firmwareDownloadStatus command to monitor progress. If the problem persists - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 860
Severity WARNING Probable Cause Indicates that the firmware download process has completed normally on the switch. Recommended Action Run the firmwareShow command to verify the firmware versions. Run the switchShow command to make sure the switch is enabled. SULB-1034 Message Relocation of - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 861
. This is generally logged before download and after download of the firmware to store version information. Recommended Action No action is required. SULB-1037 Message HCL failed. Reboot the switch manually using the reboot command. However, it will disrupt the FC traffic. Message Type AUDIT - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 862
in progress, it will continue without updating the co-CPU firmware. Recommended Action After the firmware download completes, reboot the CP manually to bring up the co-CPU and run the firmwareDownload command again. If the problem persists, your switch service provider. SULB-1039 Message CP has - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 863
Indicates that the firmwareActivate command has completed successfully and the switch firmware has been updated. Recommended Action No action is required. The firmwareActivate command has completed as expected. Run the firmwareShow command to verify the firmware versions. SULB-1043 Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 864
Cause Indicates that the firmwareDownload command to the secondary partition has completed successfully and the switch will come up with the updated firmware on reboot. Recommended Action No action is required. The switch will auto-reboot with the downloaded firmware. 842 Fabric OS Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 865
the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade. For a non-bladed switch, reboot or power cycle the switch. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 866
Action For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade. For a non-bladed switch, reboot or power cycle the switch. SWCH-1006 Message HA state out of sync: Standby CP (ver = ) does not support NPIV functionality. (active - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 867
the switch port distance or speed settings for the port to blade enabled with the port configuration that does not support port swap. Recommended Action Replace the blade with ports that support port swap. Then swap ports back to the port's default area. Refer to the Fabric OS Administrator's Guide - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 868
Area (TA) enabled on slot with switch not in PID format 1. TA enabled ports will be persistently disabled. Message Type LOG Severity WARNING Probable Cause Indicates that the blade is enabled with the port configuration that had Trunk Area enabled previously. Recommended Action - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 869
disabled for one or more ports and the configuration file has been updated. Recommended Action No action is required. SWCH- problem or due to file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, execute the firmwareDownload command to update the firmware - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 870
(NPIV) device and the static persistent PID is set on set on the device and the requested area cannot be assigned because it is user bound to a different port. Remove the WWN-PID binding using the wwnaddress --unbind command or remove the port address binding using the portaddress --unbind command - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 871
of service (QoS). Recommended Action Load a firmware version on the standby CP that supports QoS links to Access Gateway by using the firmwareDownload command. SWCH-1021 Message HA state out of sync: Standby CP (ver = ) does not support Dynamic area on default switch - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 872
number> has been disabled due to port address conflict while enabling FMS mode. Message Type LOG Severity WARNING Probable Cause Indicates that the switch has ports with FICON Management Server (FMS) reserved areas (0xFE, 0xFF) that are not supported in FMS mode. Recommended Action No action - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 873
time configured on the default switch. Recommended Action To know the edge hold time configured for non 16 Gbps-capable FC ports, go to the default switch and execute the configShow command. SWCH-1026 Message HA state out of sync: Standby CP (ver = ) does not support auto - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 874
firmware or the nonvolatile storage may be corrupted. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. SYSC-1002 Message Switch command to gather troubleshooting - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 875
daemon is not restarted, either because a restart limit is reached or a restart action fails. Recommended Action Execute the supportSave command to gather troubleshooting data. Execute the reboot or haFailover command to recover the system. Fabric OS Message Reference 853 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 876
. Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. SYSM-1002 Message , Switch: . Message Type LOG Severity INFO Probable Cause Indicates a user has executed either the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 877
> is incompatible with the chassis type. Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates this chassis type is not compatible with the control processor (CP) blade. Recommended Action Use the CP blade on a compatible chassis. Fabric OS Message Reference 855 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 878
5 SYSM-1007 SYSM-1007 Message PERMITTING USE OF INCOMPATIBLE CHASSIS FOR CP IN SLOT . DATA ERRORS MAY RESULT. Message Type LOG Severity WARNING Probable Cause Indicates an override of the incompatible control processor (CP) or chassis check. This message is for engineering use - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 879
TAPE-1001 5 TAPE Messages TAPE-1001 Message Key acquisition for . Message Type LOG Severity INFO Probable Cause Indicates that the key acquisition for the pool or the container has begun or is complete. Recommended Action No action is required. - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 880
(as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. TRCE-1002 Message Trace dump automatically transferred to address ' '. Message Type LOG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 881
Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. TRCE-1006 Message FTP Connectivity Test succeeded to FTP site ' '. Message Type LOG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 882
to bladed switches. Recommended Action This message is often transitory. Wait a few minutes and try the command again. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 883
-CP system) or restart the switch. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. TRCE-1011 Message Trace dump manually transferred to target ' - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 884
WARNING Probable Cause Indicates that a trace dump has occurred on the switch or the specified slot, but the trace dump files were not automatically transferred from the switch because FIPS mode is enabled on the switch. Recommended Action No action is required. 862 Fabric OS Message Reference - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 885
name or password is entered incorrectly. Recommended Action Normally, this message indicates a typing error by an authorized user. If this message occurs repeatedly, it may indicate an unauthorized user trying to gain access to a switch. When secure mode is enabled on the fabric, the IP address of - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 886
configuration change for the switch. The track change feature records any change to the configuration file in nonvolatile memory, including a configuration download. This message is not generated for a configuration upload. All configuration Run the trackChangesSet 1 command if you want to enable the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 887
command to verify that the principal or primary FCS switch has the clock server IP configured correctly, and the configured clock server is accessible to the switch and functional. If the principal or primary FCS does not support the feature, either choose a different switch for the role or reset - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 888
Indicates that a switch is trying to set the clock server, which is not the primary fabric configuration server (FCS) across the fabric. A consistent FCS policy must be implemented across the fabric. Recommended Action Execute the secPolicyShow command to verify that the FCS policy is consistent - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 889
Recommended Action No action is required. TS-1008 5 Fabric OS Message Reference 867 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 890
displayed in the message is the address of the path database and provides configured and the second port number displayed is what the protocol is using. Recommended Action Run the switchDisable command and then the switchEnable command to reset the routing database. Run the uRouteShow command - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 891
. Message Type AUDIT | LOG Class CFG Severity INFO Probable Cause Indicates that in-order delivery (IOD) option has been disabled on the switch. This may cause out-of-order delivery of frames during fabric topology changes. Recommended Action No action is required. UCST-1023 Message Dynamic - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 892
. Message Type AUDIT | LOG Class CFG Severity INFO Probable Cause Indicates that Dynamic Load Sharing (DLS) option has been disabled on the switch. Recommended Action No action is required. UCST-1026 Message LossLess-DLS option has been enabled. Message Type AUDIT | LOG Class CFG Severity - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 893
This error will end the current shortest switch is unreachable because the traffic isolation (TI) zone and the fabric configuration are incompatible. Recommended Action Clear all TI zones and then create a valid TI zone for your fabric configuration. Refer to the Fabric OS Administrator's Guide - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 894
5 VDR-2001 VDR Messages VDR-2001 Message . Message Type LOG Severity WARNING Probable Cause Indicates that the Field-Programmable Gate Array (FPGA) parity error threshold exceeded. Recommended Action Power cycle the switch. 872 Fabric OS Message Reference 53-1002749-01 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 895
port. Recommended Action Execute the fapwwn command to map the device, port, or AG port. You can ignore this message if the virtual PWWN is not required. VS-1002 Message The Virtual PWWN assignment for the device , port (AG port ) is timed out - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 896
has been enabled for the first time on the switch or the configuration file was corrupted or accidently removed. Recommended Action Creating a new default configuration file. Execute the configDownload command to download any of your earlier configurations for the virtual PWWN feature. VS-1005 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 897
daemon (vsd) startup because vsd has failed to register with Fabric OS State Synchronization (FSS). Recommended Action No action is required. VS-1008 Message Virtualization services failed to create timer. Message Type LOG Severity INFO Probable Cause Indicates failure in the virtualization - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 898
file is either invalid or absent. Recommended Action Install a valid certificate file. WEBD-1002 Message Missing or Invalid Key file -- HTTPS is configured but could not be started. Message Type LOG Severity WARNING Probable Cause Indicates the Secure Sockets Layer (SSL) key file is either - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 899
. WEBD-1007 Message HTTP server and weblinker process will be restarted due to change of IP Address. Message Type LOG Severity INFO Probable Cause Indicates the IP address of the switch changed and the Hypertext Transfer Protocol (HTTP) server is restarted. Recommended Action No action is - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 900
a rare error condition in which the built-in recovery process has failed to restore Hypertext Transfer Protocol (HTTP) services. The problem often results from invalid configuration of Secure Sockets Layer (SSL) certificates, but there can be more than one reason for such a failure. Recommended - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 901
your vendor's customer support for assistance. XTUN-1002 Message FCIP Tunnel Exchange timeout:I/T/L://. Message Type LOG Severity ERROR Probable Cause Indicates that the Fibre Channel Protocol (FCP) exchange - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 902
your vendor's customer support for assistance. XTUN-1004 Message FCIP Tunnel Exchange aborted:I/T/L://. Message Type LOG Severity ERROR Probable Cause Indicates that the Fibre Channel Protocol (FCP) exchange - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 903
ERROR Probable Cause Indicates that a Fibre Channel (FC) Received frame event was posted, but the frame was dropped due to an invalid receive length. This error occurs only on faulty hardware. Recommended Action Contact your vendor's customer support for assistance. XTUN-1996 Message FTRACE - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 904
job failure associated with this event, contact your vendor's customer support for assistance. XTUN-1998 Message FTRACE buffer - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 905
5 XTUN-2000 Message FCIP Tunnel UP. Message Type LOG Severity INFO Probable Cause Indicates that the specified Fibre Channel over IP (FCIP) tunnel is up. Recommended Action No action is required. XTUN-2001 Message FCIP Tunnel DOWN ( - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 906
FCIP Tunnel -Pri QoS UP. Message Type LOG Severity INFO Probable Cause Indicates that the specified quality of service (QoS) for this tunnel is up. This applies to the data classes only. When the F-Class comes online, the tunnel itself is marked as - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 907
XTUN-2007 5 XTUN-2007 Message FCIP Tunnel Circuit CREATED (). Message Type LOG Severity INFO Probable Cause Indicates that the specified circuit has been successfully created. Recommended Action No action is required. XTUN-2008 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 908
the status of the module FIPS compliance has changed. Recommended Action No action is required. XTUN-2020 Message FCIP Tunnel DELETED (). Message Type LOG Severity INFO Probable Cause Indicates that the specified Fibre Channel over IP (FCIP) tunnel has - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 909
INFO Probable Cause Indicates that the attribute is modified. In most cases, the attribute value is modified within the specified Fibre Channel over IP (FCIP) tunnel. Recommended Action No action is required. XTUN-2024 Message FCIP Tunnel Circuit - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 910
5 XTUN-2025 XTUN-2025 Message FCIP Tunnel Circuit MODATTR (). Message Type LOG Severity INFO Probable Cause Indicates that the attribute is modified. In most cases, the attribute value is modified within the specified - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 911
and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable if necessary. ZEUS-1002 Message Port chip faulted due to internal error. Message Type LOG | FFDC Severity ERROR Probable Cause Indicates an internal error. All ports on the blade or switch will be - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 912
pointer, chan:, good_addr:0x bad_addr:0x. Message Type reset failure. Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 913
Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. ZEUS-1028 Message Detected excessive Link resets on the port in a second. Slot , Port - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 914
addressable memory (CAM) entries before the filter setup. Recommended Action If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service in the effective configuration. ZONE-1004 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 915
entries before the filter setup. Recommended Action Avoid this problem in the following ways: • Avoid having too many hosts zoned with a set of target devices supported in Fabric OS version 4.x or later. Even if the QuickLoop zoning configuration is enabled on the switch, it will not be supported - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 916
zoning configuration has more than one initiator. This is because of incorrect entries in the FA zoning configuration. switches. If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 917
that the effective zone configuration has changed to security policy. ZONE-1023 Message Switch connected to port () is problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 918
Bad Zone Config: The new configuration is not viable. • Zoning Operation failed: A zoning operation failed. • Shell exited: The command shell has exited. • Unknown: An error was received for an unknown reason. • User Command: A user aborted the current zoning transaction. • Switch Shutting Down: The - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 919
will save the faulty zone configuration in the zoned core file directory. Recommended Action If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. ZONE-1034 Message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 920
ERROR Probable Cause Indicates that the Fabric OS cannot allocate enough memory for the zone configuration file. Typically, the zone configuration is too large for the memory available on the switch. Recommended Action Reduce the size of the zone database and retry the operation. 898 Fabric - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 921
Message Type LOG Severity ERROR Probable Cause Indicates that the Fabric OS cannot read the zone configuration file. Typically, the zone configuration is too large for the memory available on the switch. Recommended Action Reduce the size of the zone database and retry the operation. ZONE-1040 - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 922
LOG Severity INFO Probable Cause Indicates that the effective zone configuration has been disabled. Recommended Action Verify the event was planned Default Zone access mode is set to All Access. Message Type LOG Severity INFO Probable Cause Indicates that the Default Zone access mode is set - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 923
Severity ERROR Probable Cause Indicates that there is an Admin Domain (AD) Default Zone conflict. Recommended Action Verify that the default zoning mode for AD0 is set to No Access using the defzone --show command. If the default zoning mode is not set to No Access, execute the defzone --noaccess - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 924
Recommended Action Remove frame redirection zones or set the Default Zone access mode to No Access using the defzone --noaccess command. ZONE-1057 Message TI Zone has domain running pre FOS6.4.0 firmware. TI member (Domain - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 925
may result in an unroutable condition or an unexpected routing behavior. Recommended Action Execute the zone --showTIerrors command on the specified switch to report the conflicting configuration details. ZONE-1060 Message Non-TI and TI failover-enabled traffic restricted to domain - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 926
and effective configurations are different. Recommended Action Execute the cfgEnable command to make both the configurations consistent. ZONE zone object set. The zone object type variable can be an alias, zone member, zone, or zone configuration. The string "..." appears at the end of the zone - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 927
specified zone object member or members have been removed from the specified zone object set. The zone object type variable can be an alias, zone member, zone, or zone configuration. The string "..." appears at the end of the zone object member list variable if the list was truncated in the message - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 928
was not planned, take appropriate action as defined by your enterprise security policy. ZONE-3008 Message Event: , Status: success, Info: Current zone configuration saved to MRAM. . Message Type AUDIT Class ZONE Severity INFO Probable Cause Indicates that the current zone - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 929
ZONE-3009 5 Recommended Action Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. ZONE-3009 Message Event: , Status: success, Info: - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 930
FABRIC Severity INFO Probable Cause Indicates that the specified new Admin Domain (AD) object member or members have been added to an AD object set. The AD object set type variable can be an AD alias or AD member. The string "..." appears at the end of the AD object member list variable if the - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 931
Severity INFO Probable Cause Indicates that all Admin Domain (AD) definitions and all zone configurations under them have been cleared. Recommended specified Admin Domain (AD) has been created. The AD object set type variable can be an AD alias or AD member. The string "..." appears at the end of - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 932
Name>, Status: success, Info: \"\" removed from \"\". Message Type AUDIT Class FABRIC Severity INFO Probable Cause Indicates that the specified Admin Domain (AD) member or members have been removed from the AD. Recommended Action - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 933
FABRIC Severity INFO Probable Cause Indicates that the current Admin Domain (AD) configuration has been saved to flash memory. Recommended Action FABRIC Severity INFO Probable Cause Indicates that the ad --apply command has failed because of a transaction conflict. Recommended Action Verify - Dell Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guide - Page 934
Name> Info: executed. In AD . Message Type AUDIT Class FABRIC Severity INFO Probable Cause Indicates that the ad --exec command was executed in the specified Admin Domain (AD). Recommended Action Verify that the event was planned. If the event was planned, no action is required. If the
53-1002749-01
14 December 2012
®
Fabric OS
Message Reference
Supporting Fabric OS v7.1.0