Dell OptiPlex 7080 Small Form Factor Service Manual
Dell OptiPlex 7080 Manual
![]() |
View all Dell OptiPlex 7080 manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell OptiPlex 7080 manual content summary:
- Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 1
OptiPlex 7080 Small Form Factor Service Manual Regulatory Model: D15S Regulatory Type: D15S001 May 2020 Rev. A00 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 2
of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 3
instructions...5 Before working inside your computer...5 Safety precautions...6 Electrostatic discharge-ESD protection...6 ESD field service ...12 System management features...13 Dell Client Command Suite for In-Band systems management 13 Chapter 3: Field service information 15 Side cover...15 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 4
the power-supply unit...49 System board...53 Removing the system board...53 Installing the system board...56 Chapter 4: Troubleshooting...61 Dell SupportAssist Pre-boot System Performance Check diagnostics 61 Running the SupportAssist Pre-Boot System Performance Check 61 Diagnostic LED behavior - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 5
and the contacts. CAUTION: You should only perform troubleshooting and repairs as authorized or directed by the Dell technical assistance team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. See the safety instructions that is shipped with the product or at - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 6
disassembly instructions. electrocuted. Standby power Dell products with standby power through the use of a field service electrostatic discharge (ESD) kit. When obvious, such as intermittent problems or a shortened product of damage to recognize and troubleshoot is the intermittent (also called - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 7
ESD bag should be folded over and taped shut and all the same foam packing material should be used in the original box that the new part arrived in servicing Dell products. In addition, it is critical that technicians keep sensitive parts separate from all insulator parts while performing service - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 8
Steps 1. Replace all screws and ensure that no stray screws remain inside your computer. 2. Connect any external devices, peripherals, or cables you removed before working on your computer. 3. Replace any media cards, discs, or any other parts that you removed before working on your computer. 4. - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 9
USB type-C Alt mode: 4096 x 2304 @60 Hz • Option VGA: 1920 x 1200 @60 Hz • Option HDMI2.0: 4096 x 2160 @60 Hz Up to three displays supported • Two motherboard integrated DP1.4 HBR2 + One video option (VGA/DP1.4 HBR2/HDMI2.0/USB3.2 Gen2 type-C Alt-mode) Two MB integrated DP1.4 HBR2 + One video option - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 10
GT 730 specifications (continued) Feature Values Open CL 1.1 Open GL 4.5 GPU memory interface 64 bit PCIe bus PCIe 3.0 x8 Display support One DisplayPort 1.2 Graphics memory configuration 2 GB, GDDR5 Graphics memory clock speed 2.5 GHz Active fan sink 2-pin excluded fan controller - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 11
R5 430 Table 4. AMD Radeon R5 430 specifications Feature GPU frequency DirectX Shader model Open CL Open GL GPU memory interface PCIe bus Display support Graphics memory configuration Graphics memory clock speed Active fan sink Slot number PCB form factor Values 780 MHz 11.2 5.0 1.2 4.2 64 bit PCIe - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 12
memory configuration 6 GB GDDR6 Bus type Memory interface width Memory speed PCIe Gen 3 x16 192-bit 14 Gbps Clock speeds Display support 1785 MHz • 1 x DP 1.4 • 1 x HDMI 2.0b • 1 x DVI Dual link Maximum color depth Estimated maximum power 12 125 W Power connectors Maximum digital resolution - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 13
toolkit available for download, for all Latitude Rugged tablets at dell.com/support, automates and streamlines systems management tasks, saving time, money, to individually manage and automatically present and install Dell updates to the BIOS, drivers, and software. Command l Update eliminates the - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 14
the management console to retrieve the latest systemspecific updates (driver, firmware or BIOS). The updates are then delivered seamlessly to end-users using the customer's systems management infrastructure that is consuming the catalog (like SCCM). Dell Command | vPro Out of Band console extends - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 15
3 Field service information Topics: • Side cover • Intrusion switch • Front bezel • Hard-drive assembly • Solid-state drive • Optical drive • WLAN card • Heat images indicate the location of the side panels and provide a visual representation of the removal procedure. Field service information 15 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 16
16 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 17
Field service information 17 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 18
Steps 1. Slide the release latch to the right until your hear a click and slide the cover towards the back of the system. 2. Lift the side The following image indicates the location of the side panel and provides a visual representation of the installation procedure. 18 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 19
Field service information 19 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 20
chassis. 2. Slide the side cover towards the front of the system until you hear the release latch click. Next steps 1. Follow the procedure in after working inside your computer. Intrusion switch the existing component before performing the installation procedure. 20 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 21
the side cover. About this task The following images indicate the location of the front bezel and provide a visual representation of the removal procedure. Field service information 21 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 22
Carefully move the front bezel to an angle, until the retention tabs on the right side are released from the chassis and move the front bezel away from the system. Installing the front bezel Prerequisites provides a visual representation of the installation procedure. 22 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 23
bezel. About this task The following images indicate the location of the 2.5 in. hard-drive assembly and provide a visual representation of the removal procedure. Field service information 23 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 24
hard drive. Push the left tab towards the hard- drive to free the assembly from the chassis 2. Release the hard-drive assembly from the tabs on the right side and slide the hard drive assembly out. NOTE cage and provide a visual representation of the removal procedure. 24 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 25
installation procedure. About this task The following image indicates the location of the 2.5 in. hard-drive and provides a visual representation of the installation procedure. Field service information 25 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 26
procedure. About this task The following image indicates the location of the hard-drive bracket and provides a visual representation of the installation procedure. 26 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 27
drive assembly. About this task The following images indicate the location of the solid-state drive and provide a visual representation of the removal procedure. Field service information 27 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 28
procedure. About this task The following image indicates the location of the solid-state drive and provides a visual representation of the installation procedure. 28 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 29
drive assembly. About this task The following images indicate the location of the solid-state drive and provide a visual representation of the removal procedure. Field service information 29 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 30
procedure. About this task The following image indicates the location of the solid-state drive and provides a visual representation of the installation procedure. 30 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 31
steps 1. Install the 2.5 in. hard drive assembly. 2. Install the front bezel. 3. Install the side cover. 4. Follow the procedure in after working inside your computer. Field service information 31 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 32
task The following images indicate the location of the slim optical-drive and provide a visual representation of the removal procedure. Steps 1. Press the release tab on the optical drive caddy. 2. Slide the optical drive out of the optical drive caddy. 3. Optical drive unit. 4. Optical drive caddy - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 33
until it clicks in place. Next steps 1. Install the front bezel. 2. Install the side cover. 3. Follow the procedure in after working inside your computer. Field service information 33 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 34
WLAN card. 3. Disconnect the antenna cables from the WLAN card. 4. Slide and remove the WLAN card from the connector on the system board. 34 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 35
(black triangle) Black 2. Place the WLAN card bracket to secure the antenna cables. 3. Insert the WLAN card into the connector on the system board. Field service information 35 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 36
front bezel. About this task The following images indicate the location of the fan assembly and provide a visual representation of the removal procedure. 36 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 37
fan assembly from the system. Installing the fan assembly Prerequisites If you are replacing a component, remove the existing component before performing the installation procedure. Field service information 37 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 38
the system board and connect the heat sink fan cable to the connector on the system board. Next steps 1. Install the front bezel. 38 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 39
installation procedure. About this task The following image indicates the location of the coin-cell battery and provides a visual representation of the installation procedure. Field service information 39 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 40
side cover. About this task The following images indicate the location of the graphics card and provide a visual representation of the removal procedure. 40 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 41
Steps 1. Pull the metal tab to open the expansion card latch. 2. Pull the release tab at the base of the expansion card. 3. Lift the expansion card away from the the location of the graphics card and provides a visual representation of the installation procedure. Field service information 41 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 42
inside your computer. Memory modules Removing the memory modules Prerequisites 1. Follow the procedure in before working inside your computer. 2. Remove the side cover. 42 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 43
the installation procedure. About this task The following image indicates the location of the memory modules and provides a visual representation of the installation procedure. Field service information 43 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 44
the fan assembly. About this task The following images indicate the location of the processor and provide a visual representation of the removal procedure. 44 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 45
Steps 1. Press down and push the release lever away from the processor to release it from the securing tab. 2. Lift the lever upward to lift the processor cover. CAUTION: the location of the processor and provides a visual representation of the installation procedure. Field service information 45 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 46
, the processor is not seated properly. 2. When the processor is fully seated in the socket, close the processor cover. 3. Press down and push the release lever under the securing tab to lock it. Next steps 1. Install the heat-sink. 2. Install the side cover. 3. Follow the procedure in after working - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 47
memory modules. About this task The following images indicate the location of the power-supply unit and provide a visual representation of the removal procedure. Field service information 47 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 48
48 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 49
support bracket out from the slot. 3. Unroute the power-supply cable from the retention clip on the chassis. 4. Remove the three screws (M6X32) that secure the power-supply unit to the back of the chassis. 5. Press the power-supply unit release installation procedure. Field service information 49 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 50
50 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 51
Field service information 51 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 52
52 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 53
secure it with the two screws (M6X32). 6. Insert the SATA cables through the retention clip on the support bracket. Next steps 1. Install the memory modules. 2. Install the 2.5 in. hard-drive assembly. board and provide a visual representation of the removal procedure. Field service information 53 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 54
54 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 55
Field service information 55 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 56
installation procedure. About this task The following image indicates the location of the system board and provides a visual representation of the installation procedure. 56 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 57
Field service information 57 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 58
58 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 59
. 12. Reconnect the internal speaker cables. Next steps 1. Install the processor. 2. Install the fan assembly. 3. Install the WLAN card. 4. Install the solid-state drive. Field service information 59 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 60
5. Install the memory modules. 6. Install the 2.5 in. hard-drive assembly. 7. Install the side cover. 8. Follow the procedure in after working inside your computer. 60 Field service information - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 61
Troubleshooting Topics: • Dell SupportAssist Pre-boot System Performance Check diagnostics • Diagnostic LED behavior • Diagnostic error messages • System error messages • WiFi power cycle Dell • View error messages that inform you of problems encountered during testing NOTE: Some tests for specific - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 62
version If problem persists, replace the system board. Power rail failure • EC ran into power sequencing failure. • If problem persists, replace the system board. SBIOS Flash corruption • Flash corruption detected by SBIOS • If problem persists, replace the system board. 62 Troubleshooting - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 63
waiting on ME to reply to HECI message If problem persists, replace the system board. CPU Power Cable correct path name. The primary cache internal to the microprocessor has failed. Contact Dell The optical drive does not respond to commands from the computer. The hard from an Troubleshooting 63 - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 64
computer, reinstall the hard drive, and restart the computer. If the problem persists, try another drive. Run the Hard Disk Drive tests in Dell Diagnostics. The hard drive does not respond to commands from the seated. Reinstall the memory module or, if necessary, replace it. 64 Troubleshooting - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 65
Help and Support for instructions (click Start > Help and Support). If a Dell. The reserve battery that supports the system configuration settings may require recharging. Connect your computer to an electrical outlet to charge the battery. If the problem persists, Contact Dell. The time or date - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 66
nnnn]. For help in resolving this problem, please note this checkpoint and contact Dell Technical Support CMOS checksum error CPU fan failure . The following procedure provides the instructions on how to conduct a WiFi power cycle: NOTE: Some ISPs (Internet Service Providers) provide a modem/router - Dell OptiPlex 7080 | Small Form Factor Service Manual - Page 67
, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. About this task Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To
![](/manual_guide/products/dell-optiplex-7080-small-form-factor-service-manual-6599078/1.png)
OptiPlex 7080 Small Form Factor
Service Manual
Regulatory Model: D15S
Regulatory Type: D15S001
May 2020
Rev. A00